Download 5000-6.2.10, Pyramid Integrator, Installation Manual
Transcript
Chapter 12 Configuring Hardware for the MicroVAX Information Processors See Table 12.B for test numbers to use for testing the devices. 3. View the results of the self test. If the test was: You will see the selftest number followed by: Successful ... For example, a successful selftest of the floating point unit looks like this: 9... Not successful ?.. and the message 84 FAIL. For example, an unsuccessful selftest of the floating point unit looks like this: 9?.. 84 FAIL To find out what the error is, display the system configuration table. For more information, go to the next section. Display SelfTest Error Codes in System Configuration Table To see the error codes for all tested devices, bring up the system configuration table. This table gets updated every time the MicroVAX Information Processor is powered up or a self-test is run. 1. At the console prompt, enter: TEST 50 You will see the system configuration table looks similar to this: KA42-IN V2.1 ID 00-00-BC-01-01-C7 CLK 0000.0001 NVR 0000.0001 DZ 0000.4001 V0.1 00000001 00000001 00000001 00004001 0000000 00000000 MEM 0002.0001 00200000 000000002 MM 0000.0001 FP 0000.0001 IT 0000.0001 SCSI-A 2828.0001 1000.0001 FFFFFF05 FFFFFF05 FFFFFF05 FFFFFF05 FFFFFF05 FFFFFF05 SCSI-B 1C1C.0001 1000.0001 FFFFFF05 FFFFFF05 FFFFFF05 FFFFFF05 FFFFFF05 FFFFFF05 SYS 0000.0001 BPI 0000.0005 V0.7 NI 0000.0001 12-7