Ionic boiler “Beril” (further – boiler) is made for water heating for inhabited and uninhabited area
closed autonomous heating systems, with conditions that these areas has insulation and
ventilation (has no atmospheric precipitation or moisture condensation), outdoor air temperature
is +40˚ C to -40˚ C, relative air humidity 98% at +25˚ C.
1. TECHNICAL SPECIFICATION
Rated power frequency (Hz)
50+/-1
Max outgoing temperature from boiler (C)
80
Usable heating liquid
„BERIL” vai „BERIL VIP”
Heating liquid capacity of the boiler consumed power1 kW (l)
15
Current
IPX3 (protected against spatter)
Execution of the anti-humidity protection degree
Main dimensions and characteristics
Model
BERIL 2,5
BERIL 3
BERIL 4
BERIL 5
BERIL 6
BERIL 9
BERIL12
BERIL 15
BERIL 25
Rated
voltage
V
220
220
220
220
380
380
380
380
380
Rated
power
kW
2,5
3
4
5
6
9
12
15
25
Weight
kg
Dimensions
mm
Heated area,
m3
1,5
1,0
1,5
1,0
6,5
6,5
6,5
6,5
6,5
70x230
70x230
70x230
70x230
130x440
130x440
130x440
130x440
130x440
62,5
75
100
125
150
225
300
375
625
2. PACKAGE
1.
2.
3.
4.
5.
6.
Boiler “Beril”
Boiler manual
Boiler packaging
CP “Beril” control unit or “BERIL” control module
Control unit or module packaging
CP “Beril” manual
3. SAFETY REQUIREMENTS
When installing the boiler heating system, it must be grounded.
Boiler conducting parts (clamps) must be protected.
Electrical power protection against power overloads and short-circuiting are made with an
automatic switch to a power interruption, depending on the boiler capacity.
Must be strictly followed "PHASE-ZERO-GROUND"
Heating system threaded or welded joints must ensure airtight.
Not allowed water on the external surfaces of the boiler.
To the boiler service is admitted to persons who are older than 18 years old, who know the boiler
design and the provisions of the boiler.