Download 703186 Rev A - Use Guide, Canine, Stifle Wrap.ai

Transcript
TM
TM
Canine Stifle Wrap
Canine Stifle Wrap
Canine Stifle Wrap Application
MADE
IN
CHINA
TM
MADE
IN
CHINA
High
Med
Canine Medium Stifle Sleeve, Right: 542422
Canine Medium Stifle Heat Exchanger, Right: 562422
Canine Medium Stifle Sleeve, Left: 542424
Canine Medium Stifle Heat Exchanger, Left: 562424
Wrap Strap (2 included with Sleeve): 543080
Wrap
Avg.
Temp.
55/13
50/10
Low
Off
45/7
Pressure
40/5
ºF/ºC
Sleep
Time
Run
Time
Bath
Ice
Temp.
Place the Stifle Wrap(s) around the dog’s
hind leg(s). Position the Wrap on the dog’s
stifle, matching the bend in the Wrap to
the bend in the dog’s leg. Secure by using
the Wrap Straps and adjust as necessary
to create a comfortable, snug fit. The
Wrap connector should align vertically on
the outside of the dog's leg.
TM
*When using one Wrap, attach the Single
Connector Hose to the Wrap. Connect the
opposite end of the Connector Hose into the
Control Unit.
**When using two Wraps simultaneously,
use the Dual Connector Hose. Raise the hose
up and over the hind end of the dog to make a
"Y" split. Connect each hose end to its
corresponding Wrap. Adjust the length of the
hose by moving the barrel lock up or down.
Connect the single opposite end of the
Connector Hose into the Control Unit.
Do not allow hose to bend the Wrap at
connection. This can impede flow, and affect
cooling.
During treatment, the dog must be
accompanied by an attendant.
High
Med
Wrap
Avg.
Temp.
55/13
50/10
Low
e Off
45/7
Pressur
40/5
ºF/ºC
Sleep
Time
Run
Time
Bath
Ice
Temp.
Sh
ow
nh
ere
After treatment, disconnect the Hose from
the Wrap first, before removal of Wrap from
the dog.
Warning: Always consult with your veterinarian before using the Game Ready System.
Caution: Do not place directly against open wounds, sores, rashes, infections, or
stitches. First place a sterile dressing on the wound and then apply the Wrap. If
pressure appears uncomfortable, pause treatment, and restart with lower pressure. Do
not store in closed plastic bag after use, as this will promote mold growth. Do not
puncture Wrap, doing so will void Game Ready warranty.
Care: Gently remove Heat Exchanger from the Sleeve. Hand wash the Sleeve in cold
water and a mild detergent, or antibacterial soap. Hang to dry. Wipe down the Heat
Exchanger with cold water and a mild detergent, do not machine wash
wash. Doing so will
void warranty. Periodically run hydrogen peroxide through your Game Ready System to
keep the interior water chamber of your Wrap clean. See Control Unit User's Manual for
more detail.
Warranty Information:
Sleeve: In case of manufacturer defect, sleeve may be returned within 7 days of
purchase.
Heat Exchanger: 1 year from date of purchase. See warranty card included with Heat
Exchanger.
CoolSystems, Inc.
1201 Marina Village Pkwy Suite 200
Alameda, CA 94501
1-888-GAMEREADY
www.gamereadycanine.com
Caution: Do not open zipper on the Wrap
while Wrap is in use.
703186 Rev A
Game Ready 2008
TM
Canine Stifle Wrap =
+
Stifle Heat Exchanger
Canine Stifle Wrap
Stifle Sleeve
Fig 1
Stifle Wrap (Sleeve/Heat Exchanger) - Assembly
INE
CAN
RIGHT
LE
STIF
IUM
MED
80TPES22/TODM/SMETSYSLOOC
/1XA/780309
fig. 1 Organize Heat Exchanger with Sleeve on flat surface. Place
Black Side Up
Sleeve with logo side up and open the zipper.
80TP
ES22
/CNE
F/SM
ETSY
SLOO
C/1X
A/88
0309
Open
Zipper
fig. 2 Insert Heat Exchanger into the Sleeve with green side down.
(Green side of Heat Exchanger should touch green side of Sleeve)
Make sure the Heat Exchanger is flat inside the Sleeve with no
Fig 2
INE
CAN
RIGHT
LE
STIF
IUM
MED
folds or creases. Zip up the Sleeve.
INE
CAN
RIGHT
LE
STIF
IUM
MED
fig. 3 After assembly, lay the green side up, make sure the Wrap is flat
and smooth.
4
Insert
80TPES22/TODM/SMETSYSLOOC
/1XA/780309
Black Side Up
(Green Side Down)
fig. 4 To apply straps, attach one end of the hook portion of each strap
Zip
Closed
80TP
ES22
/CNE
F/SM
ETSY
SLOO
C/1X
A/88
0309
to one side of the Stifle Sleeve as shown.
Fig 3
Fig 4 Attaching Straps
Stifle Wrap (Sleeve/Heat Exchanger) - Disassembly
7030 ENT
.A Y
34 Rev #7,1
98,0
A
93
Inspect for folds
STIF
MED LE HXT
1.88
.
.
MA 8.GAMER
#562 RIGHT
DE
422
PAT IN U.S EAD
US
1 Disconnect the Connector Hose from the Wrap
INE
CAN
RIGHT
LE
STIF
IUM
MED
CHIN
A
2 Unzip the zipper
MADE
IN
CHINA
3 Gently pull out the Heat Exchanger
LOT LABEL
MADE
IN
CHINA