Download CTRIO Version 2.0 User Manual, Second Edition

Transcript
Chapter 1: Introduction
CTRIO Specifications
General
Module Type
Modules Per Base
I/O Points Used
Field Wiring Connector
Internal Power Consumption
Operating Environment
Manufacturer
Isolation
Intelligent
Limited only by power consumption
None, I/O map directly in PLC V-memory or PC control access
Standard removable terminal block
400mA Max at +5V from Base Power Supply (H2, H4, T1H-CTRIO)
250mA at +5V from Base Power Supply (H0-CTRIO)
(All I/O in ON State at Max Voltage/Current)
32°F to 140°F (0°C to 60°C), Humidity (non-condensing) 5% to 95%
Host Automation Products, LLC
2500V I/O to Logic, 1000V among Input Channels and All Outputs
CTRIO Input Specifications
Inputs (H2, H4, T1H-CTRIO)
Inputs (H0-CTRIO)
Minimum Pulse Width
Input Voltage Range
Maximum Voltage
Input Voltage Protection
Rated Input Current
Minimum ON Voltage
Maximum OFF Voltage
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response
8 pts. sink/source 100K Hz Max
4 pts. sink/source 100K Hz Max
5 µsec
9-30VDC
30VDC
Zener Clamped at 33VDC
8mA typical 12mA maximum
9.0VDC
2.0VDC
5.0mA (9VDC required to guarantee ON state)
2.0mA
Less than 3 µsec
Less than 3 µsec
CTRIO Input Resources
Counter/Timer (H2, H4, T1H-CTRIO) 4, (2 per each 4 input channel group); supports 2 quadrature counters max.
2, (2 per single 4 input channel); supports 1 quadrature counter max.
Counter/Timer (H0-CTRIO)
1X, 2X, or 4X Quadrature, Up or Down Counter, Edge Timer, Dual Edge Timer,
Resource Options
Input Pulse Catch, Reset, Inhibit, Capture
앧4.2 billion (32 bits); 1 µsec
Timer Range/ Resolution
Counter Range
앧2.1 billion (32 bits or 31 bits + sign bit)
Counter I/O User Manual
1–5