Print/cancel statistics (X8/43)
This input signal starts the printing out of statistical results via the serial interface "X10".
In case the input signal "Accept value into statistics" is activated simultaneously, all statistics registers are deleted. Therefore, printing out the results can
be repeated as often as desired (e.g. after paper jam) provided that the input
signal "Accept value into statistics" is not activated simultaneously.
Accept value into statistics (X8/42)
When activating this input, the measuring time is started according to the configuration setting ("STRT man"; "STRT Tm"; "STRT Tp").
If "STRT man" or "STRT Tp" has been chosen, the measuring time or the interval measurement is terminated when deactivating this input.
After the measuring time has run out, the result selected under "Sel.stat" is
accepted into the statistics. The measuring result is printed out if the printer interface has been activated in the configuration settings.
If "STRT Tm" has been chosen, the input has to be activated at least until the
preset measuring time has run out. If the input is deactivated before the
measuring time has run out, the measuring time will be aborted and the
measuring value will not be accepted into the statistics.
X8/42
X8/43
Print
n
1
2
3
...
5320
5321
Delete
Print
1
2
3
Fig. 10
Function of the input X8/42
Synchronization (start meas./ref.) (X8/10)
Via this input signal, the measuring/reference function, i.e. the zero point correction of a connected measuring instrument, is activated on the reference instrument (see section 6.6 "Zero point correction by means of the measuring/reference function").
Synchronization successful (X5/17)
Synchronization error (X5/16)
Both signals are cancelled when starting the function "Synchronize". In case
the harmonization of the zero points is successful, the X5/17 signal is activated. If an error occurs during the harmonization or if the calculated correction value exceeds the adjustable parameter "max.Corr.", the output X5/16 is
activated.
36