Download Tetra USA Manual Iss..
Transcript
Safety Certification: Tetra is classified to both US and Canadian standards by Underwriter Laboratories Inc as suitable for use in Class 1 Groups A, B, C, D.Division I locations. Before use read the manual to ensure a full understanding of how to operate the unit and as to any limitations of use. CH4 EEx ia d IIC T3 Ex ia d IIC T3 Baseefa03ATEX0193 IECEx BAS 04.0024 1180 0 -4F/-20 C 0Ta 131F/55 C II 2G ONLY AS TO INTRINSIC SAFETY FOR USE IN HAZARDOUS LOCATIONS, CLASS I, DIVISION 1, GROUPS A, B, C & D. TEMP. CODE T3 WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR PROCEDURES. NOT CLASSIFIED FOR USE IN ATMOSPHERES MANUAL FOR BATTERY TYPE. CHANGE BATTERIES ONLY IN A SAFE AREA. UNDERSTAND MANUAL BEFORE OPERATING CAUTION: THIS AREA MUST BE FREE OF FLAMMABLE GASES DURING CALIBRATION. CL ED S AS IFI C • Do not change or charge batteries in a hazardous location. Doing so may lead to fire or explosion. US Manufactured by Crowcon Oxon UK CH4 EEx ia d IIC T4 Ex ia d IIC T4 Baseefa03ATEX0193 IECEx BAS 04.0024 0 -4F/-20 C 0Ta 131F/55 C 1180 II 2G ONLY AS TO INTRINSIC SAFETY FOR USE IN HAZARDOUS LOCATIONS, CLASS I, DIVISION 1, GROUPS A, B, C & D. TEMP. CODE T4 WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY. TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES, READ, UNDERSTAND & ADHERE TO THE MANUFACTURER'S LIVE MAINTENANCE PROCEDURES. NOT CLASSIFIED FOR USE IN ATMOSPHERES CONTAINING GREATER THAN 21 OXYGEN. CHARGE ONLY IN A SAFE AREA. UNDERSTAND MANUAL BEFORE OPERATING CAUTION: THIS AREA MUST BE FREE OF FLAMMABLE GASES DURING CALIBRATION. CL 66Y6 C ED S AS IFI C22.2 No.152 EXia • It is recommended that the combustible gas sensor be checked with a known concentration of calibration gas after any exposure to catalyst contaminations/poisons (sulfur compounds, silicon vapors, halogenated compounds etc.) • Do not use any other charger. Other chargers may damage the detector making it unsafe for use in hazardous areas. CONTAINING GREATER THAN 21 OXYGEN. REFER TO 66Y6 • Protect the combustible gas sensor from exposure to lead compounds, silicones and chlorinated hydrocarbons. Although certain organic vapors (such as leaded gasoline and halogenated hydrocarbons) may temporarily inhibit sensor performance, in most cases the sensor will recover after calibration. • Only charge the battery using a Crowcon supplied charger. INTRINSIC SAFETY. TO PREVENT IGNITION OF FLAMMABLE OR COMBUSTIBLE ATMOSPHERES, READ, UNDERSTAND & ADHERE TO THE MANUFACTURER'S LIVE MAINTENANCE C22.2 No.152 EXia • High off-scale %LEL readings may indicate an explosive concentration. US Manufactured by Crowcon Oxon UK Warning • Extended exposure of the combustible sensor to certain concentrations of combustible gases and air may stress the sensor element, which can seriously affect its performance. If an alarm occurs due to a high concentration of combustible gases, recalibration should be performed, or if needed, the sensor replaced. • Do not test the combustible sensor’s response using a butane lighter. Doing so may damage the sensor. • Prior to each days usage, sensitivity must be tested on a known concentration of methane equivalent to 2550% of full scale concentration (accuracy must be within 0±20% of actual). Accuracy may be corrected by recalibrating the instrument. • Any rapid up-scale reading followed by a declining or erratic reading may indicate a gas concentration beyond the upper scale limit, which may be hazardous. • To avoid possible personal injury: Caution • Substitution of components may impair intrinsic safety. CAUTION: For safety reasons this equipment must be operated and serviced by qualified personnel only. Read and understand instruction manual completely before operating or servicing. • Do not use the detector if it is damaged or something is missing, contact Crowcon immediately. • Use only sensor modules specifically designed for your Tetra. (Please see the section on replacement parts and accessories.) • Periodically, “bump test” the sensor with gas to confirm its ability to respond to gas by exposing the detector to a targetted gas concentration that exceeds the high alarm setpoint. Manually verify that the audible and visual alarms are activated. • It is recommended that the detector be calibrated before first-time use, and then at least once every 90 days and only by qualified personnel. • For use in potentially explosive atmospheres where oxygen concentrations do not exceed 21%(v/v). • Do not turn off the detector during a work shift. Turning off the detector resets the time weighted average gas exposure values to zero. • Ensure that the sensor is not blocked. • Only the combustible gas detection portion of this instrument has been assessed for performance on methane according to C22.2 No.152. ATTENTION: Pour des raisons de sécurité, cet équipement doit être utilisé, entretenu et réparé uniquement par un personnel qualifié. Étudier le manuel d’instructions en entir avant d’utiliser, d’entretenir ou de réparer l’équipement. To avoid damage to the detector: • Do not expose the detector to electrical shock or severe mechanical shock. • Do not attempt to disassemble, adjust or service the detector unless instructions for that procedure are contained in the manual and/or that part is listed as a replacement part. Only use Crowcon replacement parts. • Do not immerse the detector in liquids. • The detector warranty will be voided if customer personnel or third parties damage the detector during repair attempts. Non-Crowcon repair/service attempts void this warranty.