Download LVD TEST REPORT
Transcript
Ref. No.: CE10-LIE040101S LVD TEST REPORT For LED TUBE Model: T10, T8, T5 Reference No.: CE10-LIE040101S Issued by: Shenzhen EBO Testing Center Lab location: Yihua Building, Shennan Road, Futian District, Shenzhen, 518040, P. R. China Tel: 86 755 83187996 Fax: 86 755 83709189 This test report consists of 30 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by EBO. The test results in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers and approver. Any objections must be raised to EBO within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. Page 1 of 30 Ref. No.: CE10- LIE040101S LVD REPORT per EN 60598-1:2004+A1:2006 Luminaires – Part 1: General requirements and tests EN 60598-2-1:1989 Luminaires , Part 2: particular requirements Section one – Fixed general purpose luminaires Administrative Data: Report Reference No. ................. CE10- LIE040101S Tested by (name+signature) ......... Adang Lu Approved by (name+signature) .... Kevin Yu Date of issue................................. 2010-04-01 Testing Laboratory ......................... Shenzhen EBO Testing Center Address ........................................ Yihua Building, Shennan Road, Futian District, Shenzhen, 518040, P. R. China Testing location/ procedure........... The same as above Testing location/ address .............. The same as above Applicant’s name ........................ : Shenzhen Saiju Electronic Co., Ltd. Address ........................................ 2nd. Xianshun Industrial Park, Gushu, Xixiang, Bao’an, Shenzhen, Guangdong, China. Test specification: Standard ....................................... EN 60598-1:2004+A1:2006; EN60598-2-1:1989 Test procedure ................................ CE-LVD Non-standard test method….: N/A Test Report Form No. ................. EN60598-2-1 Test item description.................. :LED TUBE Trade Mark ................................... Saiju Manufacturer ................................ Shenzhen Saiju Electronic Co., Ltd. Model/Type reference................... T10, T8, T5 General product information: 85~265V ~ 50~60Hz Page 2 of 30 Ref. No.: CE10-LIE040101S Test case does not apply to the test object : N(.A.) Test item does meet the requirement ..... : P(ass) Test item does not meet the requirement : F(ail) Testing Date of receipt of test item .......... : 2010-03-16 Date(s) of performance of test .... : 2010-03-16 to 2010-04-01 General remarks This report shall not be reproduced except in full without the written approval of the testing laboratory. The test results presented in this report relate only to the item tested. "(see remark #)" refers to a remark appended to the report. "(see Annex #)" refers to an annex appended to the report. Throughout this report a comma is used as the decimal separator. Page 3 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark 1.2 (0) GENERAL TEST REQUIREMENTS P 1.2 (0.1) Information for luminaire design considered P 1.2 (0.3) More sections applicable ............................... : P 1.4 (2) CLASSIFICATION P 1.4 (2.2) Type of protection ............................................. : Class Ⅰ P 1.4 (2.3) Degree of protection ......................................... : IP65 P 1.4 (2.4) Luminaire only suitable for non-combustible surfaces ........................................................... : N Luminaire suitable for normally flammable surfaces ............................................................ : N Luminaire suitable to be covered by insulating material. : P Luminaire for normal use ................................. : P Luminaire for rough service ............................. : N 1.4 (2.5) 1.5 (3) MARKING 1.5 (3.2) Mandatory markings 1.5 (3.3) P Refer to marking plate P Position of the marking P Format of symbols/text P Additional information Refer to marking plate P Language of instructions English P 1.5 (3.3.1) Combination luminaires N 1.5 (3.3.2) Nominal frequency in Hz 50Hz P 1.5 (3.3.3) Operating temperature +25℃ P 1.5 (3.3.4) Symbol or warning notice N 1.5 (3.3.5) Wiring diagram Refer to user manual P 1.5 (3.3.6) Special conditions Not applicable N 1.5 (3.3.7) Metal halide lamp luminaire – warning No such lamp N 1.5 (3.3.8) Limitation for semi-luminaires No semi-luminaire N 1.5 (3.3.9) Power factor and supply current Refer to marking P 1.5 (3.3.10) Suitability for use indoors P 1.5 (3.3.11) Luminaires with remote control No such structure N 1.5 (3.3.12) Clip-mounted luminaire – warning Fixed luminaries N 1.5 (3.3.13) Specifications of protective shields No this component N Page 4 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark 1.5 (3.3.14) Symbol for nature of supply ~, Refer to marking P 1.5 (3.3.15) Rated current of socket outlet No socket outlet P 1.5 (3.3.16) Rough service luminaire No such luminaries N 1.5 (3.3.17) Mounting instruction for type Y, type Z and Type Y some type X attachments P 1.5 (3.3.18) Non-ordinary luminaries with PVC cable N 1.5 (3.3.101) Adequate warning on the package (EN) 1.5 (3.4) Test with water Not applicable P See appended table 1.5 P Test with hexane P Legible after test P Label attached P 1.6 (4) CONSTRUCTION P 1.6 (4.2) Components replaceable without difficulty N 1.6 (4.3) Wire ways smooth and free from sharp edges P 1.6 (4.4) Lampholders N 1.6 (4.4.1) Integral lampholder Approved lampholder used 1.6 (4.4.2) Wiring connection 1.6 (4.4.3) Lampholder for end-to-end mounting N N No such structure N 1.6 (4.4.4) Positioning P - pressure test (N) ............................................. No applicable N - bending test (Nm) ............................................. 1.0Nm P 1.6 (4.4.5) Peak pulse voltage N 1.6 (4.4.6) Centre contact N 1.6 (4.4.7) Parts in rough service luminaires resistance to No rough service tracking N 1.6 (4.4.8) Lamp connectors N 1.6 (4.4.9) Caps and bases correctly used P 1.6 (4.5) N Starter holders Starter holder in luminaires other than class II 1.6 (4.6) No such component N Starter holder class II construction N Terminal blocks P Tails Approved terminals blocks used P Page 5 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause 1.6 (4.7) Requirement + Test Result – Remark Unsecured blocks P Terminals and supply connections P 1.6 (4.7.1) Contact to metal parts P 1.6 (4.7.2) Test 8 mm live conductor P Test 8 mm earth conductor P 1.6 (4.7.3) Terminals for supply conductors P 1.6 (4.7.3.1) N Welded connections: - stranded or solid conductor Not such connection mode N - spot welding N - welding between wires N - Type Z attachment N - mechanical test according to 15.8.2 N - electrical test according to 15.9 N - ageing test according to 15.9.2.3 and 15.9.2.4 N 1.6 (4.7.4) Terminals other than supply connection No such terminals N 1.6 (4.7.5) Heat-resistant wiring/sleeves No such structure N 1.6 (4.7.6) Multi-pole plug No N 1.6 (4.8) - test at 30 N N Switches: N - adequate rating 1.6 (4.9) plug used No switch used N - adequate fixing N - polarized supply N - compliance with 61058-1 for electronic switches N Insulating lining and sleeves P 1.6 (4.9.1) Retainment Used fiber-glass tube and thermal-shrinkable tube P Method of fixing ................................................ : Suitably length and shrink fix P 1.6 (4.9.2) Insulated linings and sleeves UL approved fiber-glass tube and thermal-shrinkable tube used P a) & c) Insulation resistance and electric strength N b) Ageing test. Temperature (°C) ..................... : N 1.6 (4.10) Insulation of Class II luminaires N 1.6 (4.10.1) N No contact, mounting surface - accessible ClassⅠluminaire metal parts - wiring of basic insulation Page 6 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark Safe installation fixed luminaires N Capacitors and switches N Interference suppression capacitors according to IEC 60384-14 N Assembly gaps: N - not coincidental N - no straight access with test probe N Retainment of insulation: N - fixed N - unable to be replaced; luminaire inoperative N - sleeves retained in position N - lining in lampholder N 1.6 (4.11) Electrical connections P 1.6 (4.11.1) Contact pressure P 1.6 (4.11.2) Screws: N - self-tapping screws N - thread-cutting screws N - at least two self-tapping screws N Screw locking: N - spring washer N - rivets N 1.6 (4.10.2) 1.6 (4.10.3) 1.6 (4.11.3) 1.6 (4.11.4) Material of current-carrying parts Copper P 1.6 (4.11.5) No contact to wood P 1.6 (4.11.6) Electro-mechanical contact systems N 1.6 (4.12) Mechanical connections and glands N 1.6 (4.12.1) Screws not made of soft metal N Screws of insulating material N Torque test: torque (Nm); part ........................... : N Torque test: torque (Nm); part ........................... : N Torque test: torque (Nm); part ........................... : N Page 7 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test 1.6 (4.12.2) Screws with diameter < 3 mm screwed into All screws are both screwed metal into metal N 1.6 (4.12.4) Locked connections: P - fixed arms; torque (Nm) .................................. : 5Nm P - lampholder; torque (Nm)................................... 1.2Nm P - push-button switches; torque 0,8 Nm ............... N Screwed glands; force (N) .................................. No such construction N 1.6 (4.12.5) Result – Remark 1.6 (4.13) Mechanical strength P 1.6 (4.13.1) Impact tests: P - fragile parts; energy (Nm) ................................. N - other parts; energy (Nm)................................... 0.35Nm P 1) live parts P Cannot be touched 2) linings P 3) protection P 4) covers P 1.6 (4.13.3) Straight test finger P 1.6 (4.13.4) Rough service luminaires N - IP54 or higher 1.6 (4.13.6) Not such luminaire N a) fixed N b) hand-held N c) delivered with a stand N d) for temporary installations and suitable for mounting on a stand N Tumbling barrel Not applicable N 1.6 (4.14) Suspensions and adjusting devices P 1.6 (4.14.1) Mechanical load: P A) four times the weight P B) torque 2,5 Nm ............................................. : P C) bracket arm; bending moment (Nm)............. : 1.0Nm , 1min P D) load track-mounted luminaires N E) clip-mounted luminaires, glass-shelve. Thickness (mm) ............................................... : N Page 8 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark metal rod. Diameter (mm) ............................... : N Fixed luminaire or independent control gear without fixing devices P Load to flexible cables P Mass (kg) .......................................................... : 0.28kg P Stress in conductors (N/mm²) ........................... : No tension will not applied to the conductors N Semi-luminaires – mass (kg) ........................... : Not applicable N Semi-luminaires – bending moment (Nm)......... : N Adjusting devices: N - flexing test; number of cycles ......................... : Not applicable N - strands broken N - electric strength test afterwards N 1.6 (4.14.4) Telescopic tubes: cords not fixed to tube; no Use fiber glass tube to strain on conductors prevent strain P 1.6 (4.14.5) Guide pulleys N 1.6 (4.14.6) Strain on socket-outlets 1.6 (4.14.2) 1.6 (4.14.3) Not applicable N 1.6 (4.15) Flammable materials: - glow-wire test 650 °C 1.6 (4.15.2) P See appended table 22.15 P - spacing ≥ 30 mm N - screen withstanding test of 13.3.1 P - screen dimensions P - no fiercely burning material P - thermal protection N - electronic circuits exempted N Luminaires made of thermoplastic material with lamp control gear N a) construction N No lamp control gear b) temperature sensing control N c) surface temperature N 1.6 (4.16) Luminaires marked with F-symbol P No lamp control gear 1.6 (4.16.1) See clause 12 Lamp control gear spacing: - spacing 35 mm N N No lamp control gear N Page 9 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause 1.6 (4.16.2) Requirement + Test - spacing 10 mm N Thermal protection: N - in lamp control gear 1.6 (4.16.3) Result – Remark No such component N - external N - fixed position N - temperature marked lamp control gear N "F" curve measured See appended table 12.5 1.6 (4.17) Drain holes Clearance at least 5 mm N No drain holes N 1.6 (4.18) Resistance to corrosion: 1.6 (4.18.1) - rust-resistance 1.6 (4.18.2) - season cracking in copper 1.6 (4.18.3) - corrosion of aluminium P N IP65 N N No such material N 1.6 (4.19) Ignitors compatible with ballast No such component N 1.6 (4.20) Rough service vibration No this luminaires N 1.6 (4.21) Protective shield: N 1.6 (4.21.1) Shield fitted No tungsten halogen lamps N 1.6 (4.21.2) Particles from a shattering lamp not impair safety N 1.6 (4.21.3) No direct path N 1.6 (4.21.4) Impact test on shield N Glow-wire test on lamp compartment N 1.6 (4.22) Attachments to lamps P 1.6 (4.23) Semi-luminaires comply class II N 1.6 (4.24) UV radiation, metal halide lamps P 1.6 (4.25) No sharp point or edges P 1.6 (4.26) Short-circuit protection: N 1.6 (4.26.1) Uninsulated accessible SELV parts 1.6 (4.26.2) Short-circuit test No uninsulated accessible SELV parts N N Page 10 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark 1.6 (4.26.3) Test chain according to Figure 29 N 1.7 (11) CREEPAGE DISTANCES AND CLEARANCES P Working voltage (V) ............................................ 230V P Voltage form AC P PTI >600 P Rated pulse voltage (kV) ................................... P 1) Current-carrying parts of different polarity: 12.2mm cr (mm); cl (mm).................................................. P 2) Current-carrying parts and accessible parts: Basic insulation and cr (mm); cl (mm).................................................. grounding protective in structure P 3) Parts becoming live due to breakdown of basic insulation and metal parts: cr (mm); cl (mm).................................................. N 4) Outer surface of cable where it is clamped and metal parts: cr (mm); cl (mm) ....................... N 5) Not used N 6) Current-carrying parts and supporting Double surface: structure cr (mm); cl (mm).................................................. 1.8 (7) insulation PROVISION FOR EARTHING P N 1.8 (7.2.1 Accessible metal parts + 7.2.3) N Metal parts in contact with supporting surface Resistance < 0,5 Ω in N See appended table 7.2.3 N Two self-tapping screws used N Thread-forming screws N Thread-forming screw used in a groove N Earth makes contact first No connecter used N 1.8 (7.2.2 Earth continuity in joints etc. + 7.2.3) N 1.8 (7.2.4) Locking of clamping means N Compliance with 4.7.3 N 1.8 (7.2.5) Earth terminal integral part of connector socket No connecter socket used N 1.8 (7.2.6) Earth terminal adjacent to mains terminals N 1.8 (7.2.7) Electrolytic corrosion of the earth terminal N Page 11 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test 1.8 (7.2.8) Material of earth terminal 1.8 (7.2.10) 1.8 (7.2.11) 1.9 (14) 1.9 (15) 1.10 (5) Result – Remark Copper N Contact surface bare metal N Class II luminaire for looping-in N Double or reinforced insulation to functional earth N Earthing core coloured green-yellow Green-yellow wire used Length of earth conductor N SCREW TERMINALS N Separately approved; component list (see Annex 1) N Part of the luminaire (see Annex 2) N SCREWLESS TERMINALS P Separately approved; component list (see Annex 1) P Part of the luminaire (see Annex 3) P EXTERNAL AND INTERNAL WIRING P 1.10 (5.2) Supply connection and external wiring 1.10 (5.2.1) N N Means of connection......................................... : Terminals N Connecting leads (EN) N - without a means for connection to the supply No used connecter leads N - terminal block specified N - relevant information provided N - compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2, 12 and 13.2 of Part 1 N Type of cable .................................................... : N Cables equal to HD21 S2 or HD22 S2 (EN) N Nominal cross-sectional area (mm²) ................. : N 1.10 (5.2.3) Type of attachment, X, Y or Z N 1.10 (5.2.5) Type Z not connected to screws N 1.10 (5.2.6) Cable entries: P 1.10 (5.2.2) - suitable for introduction Wire bushing used P Page 12 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark - adequate degree of protection P 1.10 (5.2.7) Cable entries through rigid material have rounded edges P 1.10 (5.2.8) Insulating bushings: N - suitably fixed Not Class Ⅱ equipment N - material in bushings N - material not likely to deteriorate N - tubes or guards made of insulating material N 1.10 (5.2.9) Locking of screwed bushings N 1.10 (5.2.10) Cord anchorage: N - covering protected from abrasion N - clear how to be effective N - no mechanical or thermal stress N - no tying of cables into knots etc. N - insulating material or lining N Cord anchorage for type X attachment: N 1.10 (5.2.10.1) a) at least one part fixed 1.10 (5.2.10.2) Type Y attachments N b) types of cable N c) no damaging of the cable N d) whole cable can be mounted N e) no touching of clamping screws N f) metal screw not directly on cable N g) replacement without special tool N Glands not used as anchorage N Labyrinth type anchorages N Adequate cord anchorage for type Y and type Z attachment P 1.10 Tests: (5.2.10.3) - impossible to push cable; unsafe P See appended table 5.2 P - pull test: 25 times; pull (N) .............................. : P - torque test: torque (Nm).................................. : P - displacement ≤ 2 mm P - no movement of conductors P Page 13 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark - no damage of cable or cord P 1.10 (5.2.11) External wiring passing into luminaire P 1.10 (5.2.12) Looping-in terminals 1.10 (5.2.13) Wire ends not tinned P Wire ends tinned: no cold flow N 1.10 (5.2.14) No such construct Mains plug same protection N No used plug N Class III luminaire plug N 1.10 (5.2.15) Colour code low voltage (EN) No such equipment N 1.10 (5.2.16) Appliance inlets (IEC 60320) No used inlet N Appliance couplers of class II type 1.10 (5.2.17) No standardized properly assembled interconnecting 1.10 (5.2.18) Used plug in accordance with N cables No such components - IEC 60083 N No plug used N - other standard N 1.10 (5.3) Internal wiring 1.10 (5.3.1) Internal wiring of suitable size and type P 0.75mm 2 P Through wiring - not delivered/ mounting instruction 1.10 (5.3.1.1) 1.10 (5.3.1.2) N N No through wiring N - factory assembled N - socket outlet loaded (A) .................................. : N - temperatures .................................................. : N Green-yellow for earth only N Internal wiring connected directly to fixed wiring P Cross-sectional area (mm²) .............................. : 0.75mm2 P Insulation thickness P 0.6mm Extra insulation added where necessary P Internal wiring connected to fixed wiring via internal current-limiting device N Adequate cross-sectional area and insulation thickness N Page 14 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark 1.10 (5.3.1.3) Double or reinforced insulation for class II Class I equipment 1.10 (5.3.1.4) Conductors without insulation 1.10 (5.3.1.5) SELV current-carrying parts 1.10 (5.3.1.6) Insulation thickness other than PVC or rubber N 1.10 (5.3.2) Sharp edges etc. P No moving parts of switches etc. P Joints, raising/lowering devices P Telescopic tubes etc. P No twisting over 360° P Insulating bushings: P - suitable fixed P - material in bushings P - material not likely to deteriorate P - cables with protective sheath P 1.10 (5.3.3) N N No SELV parts N 1.10 (5.3.4) Joints and junctions effectively insulated No such structure N 1.10 (5.3.5) Strain on internal wiring Not applicable N 1.10 (5.3.6) Wire carriers No such luminaire N 1.10 (5.3.7) Wire ends not tinned P Wire ends tinned: no cold flow P 1.11 (8) PROTECTION AGAINST ELECTRIC SHOCK P 1.11 (8.2.1) Live parts not accessible P Basic insulated parts not used on the outer surface without appropriate protection P Protection in any position P Double-ended tungsten filament lamp No such lamp Insulation lacquer not reliable Double-ended high pressure discharge lamp Relevant warning according to 3.2.18 fitted to the luminaire N P No such lamp N N Page 15 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test 1.11 (8.2.2) Portable luminaire unfavourable position 1.11 (8.2.3) Class II luminaire: N - basic insulated metal parts not accessible Class I luminaire during starter or lamp replacement N - basic insulation not accessible other than during starter or lamp replacement N - glass protective shields supplementary insulation N 1.11 (8.2.4) Result – Remark adjusted not in most No portable luminaire used as N Class I luminaire with BC lampholder N Portable luminaire: N - protection independent of supporting surface Not portable luminaire N - terminal block completely covered N 1.11 (8.2.5) Compliance with the standard test finger or relevant probe P 1.11 (8.2.6) Covers reliably secured P 1.11 (8.2.7) Discharging of capacitors ≥ 0,5 μF Portable plug capacitor connected luminaire No capacitors used N with N Other plug connected luminaire with capacitor N Discharge device on or within capacitor N Discharge device mounted separately N 1.12 (12) ENDURANCE TEST AND THERMAL TEST P 1.12 (12.3) Endurance test: P - mounting-position ............................................. Normal using P - test temperature (°C) ........................................ 36℃ P - total duration (h)................................................ 240H P - supply voltage: Un factor; calculated voltage 237V (V) ....................................................................... P - lamp used ......................................................... Filament lamp P After endurance test: P 1.12 (12.3.2) - no part unserviceable See appended table 12.3.2 P - luminaire not unsafe P - no damage to track system P - marking legible P Page 16 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark - no cracks, deformation etc. P 1.12 (12.4) Thermal test (normal operation) See appended table 12.4 P 1.12 (12.5) Thermal test (abnormal operation) Fixed non-adjustable filament lamp luminaires N 1.12 (12.6) Thermal test (failed lamp control gear condition): N 1.12 (12.6.1) Through wiring or looping-in wiring loaded by a No lamp control gear current of (A) ..................................................... : N - case of abnormal conditions ............................. N - electronic lamp control gear N - measured winding temperature (°C) at 1,1 Un . N - measured mounting surface temperature (°C) at 1,1 Un ............................................................. N - calculated mounting surface temperature (°C): ............................................................................ N - track-mounted luminaires N Temperature sensing control N - case of abnormal conditions ............................. N - thermal link N - manual reset cut-out N - auto reset cut-out N - measured mounting surface temperature (°C) ............................................................................ N - track-mounted luminaires N 1.12 (12.7) Thermal test (failed lamp control gear in plastic luminaires): N 1.12 (12.7.1) Through wiring or lopping-in wiring loaded by a No lamp control gear current of (A) ....................................................... N - case of abnormal conditions ............................. N - measured winding temperature (°C) at 1,1 Un . N - measured temperature of fixing point/ exposed part (°C) at 1,1 Un ................................ N - calculated temperature of fixing point/ exposed part (°C)................................................ N Temperature sensing control N - thermal link N - manual reset cut-out N 1.12 (12.6.2) 1.12 (12.7.2) Page 17 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause 1.13 (9) Requirement + Test Result – Remark - auto reset cut-out N - measured temperature of fixing point/ exposed part (°C) .............................................. N RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE P 1.13 (9.2) Tests for ingress of dust, solid objects and moisture: P - classification according to IP ............................ IP 20 P - mounting position during test............................ Up P - fixing screws tightened; torque (Nm) ................ 0.3Nm P - tests according to clauses ................................ P - electric strength test afterwards P a) no deposit in dust-proof luminaire N b) no talcum in dust-tight luminaire N c) no trace of water on current-carrying parts or where it could become a hazard N d) i) For luminaires without drain holes – no water entry N d) ii) For luminaires with drain holes – no hazardous water entry N e) no water in watertight luminaire N f) no contact with live parts (IP 2X) P f) no entry into enclosure (IP 3X and IP 4X) N f) no contact with live parts (IP3X and IP4X) N 1.13 (9.3) Humidity test 48 h P 1.14 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH P 1.14 (10.2.1) Insulation resistance test P Cable or cord covered by metal foil or replaced by a metal rod of mmØ .................................... P Insulation resistance (MΩ): P SELV: N - between current-carrying parts of different polarity............................................................... N - between current-carrying parts and mounting surface .............................................................. N - between current-carrying parts and metal parts of the luminaire......................................... N Page 18 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark Other than SELV: P - between live parts of different polarity ............. See appended table 10.2.1 P - between live parts and mounting surface ........ P - between live parts and metal parts.................. P - between live parts of different polarity through action of a switch.................................. N Electric strength test P Dummy lamp N Luminaires with ignitors after 24 h test N Luminaires with manual ignitors N Test voltage (V): P SELV: N - between current-carrying parts of different polarity............................................................... N - between current-carrying parts and mounting surface .............................................................. N - between current-carrying parts and metal parts of the luminaire......................................... N Other than SELV: P - between live parts of different polarity ............. See appended table 10.2.2 P - between live parts and mounting surface ........ P - between live parts and metal parts.................. P - between live parts of different polarity through action of a switch.................................. N 1.14 (10.3.1) Leakage current (mA)........................................ See appended table 10.3 P 1.15 (13) RESISTANCE TO HEAT, FIRE AND TRACKING P 1.15 (13.2.1) Ball-pressure test: P - part tested; temperature (°C)........................... See appended table 13.2.1 P - part tested; temperature (°C)........................... P Needle flame test (10 s): P - part tested ....................................................... See appended table 13.3.2 P - part tested ....................................................... P Glow wire test (650 °C): P 1.14 (10.2.2) 1.15 (13.3.1) 1.15 (13.3.2) Page 19 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause 1.15 (13.4.1) Requirement + Test Result – Remark - part tested ....................................................... See appended table 13.3.2 P - part tested ....................................................... P Tracking test: part tested ................................... N Page 20 of 30 Ref. No.: CE10- LIE040101S IEC 60598-2-1 and/or EN 60598-2-1 Clause Requirement + Test Result – Remark ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) P (2.2) Class 0 not accepted P (3.3) DK: power supply cord with label N IT: warning label on Class 0 luminaire N (4.5.1) DK: socket-outlets N (4.5.1) FR: socket-outlets N (5.2.1) CY, DK, FI, SE, GB: type of plug N ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N (13.3) DK: Needle flame test during 30 s N (13.3) GB: Requirements according Kingdom Building Regulation United N (13.3.2) FR: Glow-wire test 850°C alt. 750°C for luminaires in premises open to public or 960°C for luminaires in emergency exits N EUT not Class 0 to Page 21 of 30 Ref. No.: CE10- LIE040101S Critical component list object/part No. manufacturer/trademark type/model technical data standard mark(s) of conformity Page 22 of 30 Ref. No.: CE10- LIE040101S ANNEX 2: screw terminals (part of the luminaire) N (14) SCREW TERMINALS N (14.2) Type of terminal ................................................ : Pillar terminal N Rated current (A) .............................................. : Max 4A N (14.3.2.1) One or more conductors One conductors (14.3.2.2) Special preparation (14.3.2.3) Terminal size N N 0 N 2 Cross-sectional area (mm²) .............................. : 0.75mm N (14.3.3) Conductor space (mm) ..................................... : 1.5mm N (14.4) Mechanical tests P (14.4.1) Minimum distance N (14.4.2) Cannot slip out N (14.4.3) Special preparation N (14.4.4) Nominal diameter of thread (metric ISO thread) : N External wiring N No soft metal N (14.4.5) Corrosion N (14.4.6) Nominal diameter of thread (mm) ..................... : 2.88mm N Torque (Nm) ...................................................... : 0.5Nm N Between metal surfaces N Lug terminal N Mantle terminal N Pull test; pull (N)................................................ : 30N N Without undue damage N (14.4.7) (14.4.8) Page 23 of 30 Ref. No.: CE10- LIE040101S ANNEX 3: screwless terminals (part of the luminaire) N (15) SCREWLESS TERMINALS N (15.2) Type of terminal................................................. : N Rated current (A)............................................... : N (15.3.1) Material N (15.3.2) Clamping N (15.3.3) Stop N (15.3.4) Unprepared conductors N (15.3.5) Pressure on insulating material N (15.3.6) Clear connection method N (15.3.7) Clamping independently N (15.3.8) Fixed in position N (15.3.10) Conductor size N Type of conductor N (15.5.1) Terminals internal wiring N (15.5.1.1) Pull test spring-type terminals (4 N, 4 samples) N (15.5.1.2) Pull test pin or tab terminals (4 N, 4 samples) N Insertion force not exceeding 50 N N (15.5.2) Permanent connections: pull-off test (20 N) N (15.6) Electrical tests N Voltage drop (mV) after 1 h (4 samples)............ : N Voltage drop of two inseparable joints N Number of cycles .............................................. : N Voltage drop (mV) after 10th alt. 25th cycle (4 samples) ....................................................... : N Voltage drop (mV) after 50th alt. 100th cycle (4 samples) ....................................................... : N After ageing, voltage drop (mV) after 10th alt. 25th cycle (4 samples) ...................................... : N After ageing, voltage drop (mV) after 50th alt. 100th cycle (4 samples) .................................... : N Terminals external wiring N Terminal size and rating N (15.7) Page 24 of 30 Ref. No.: CE10- LIE040101S (15.8.1) (15.9) Pull test spring-type terminals or welded connections (4 samples); pull (N) .................... : N Pull test pin or tab terminals or welded connections (4 samples); pull (N) .................... : N Contact resistance test N Voltage drop (mV) after 1 h N terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Voltage drop of two inseparable joints --- Voltage drop after 10th alt. 25th cycle --- Max. allowed voltage drop (mV)......................: ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Voltage drop after 50th alt. 100th cycle --- Max. allowed voltage drop (mV)......................: ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Continued ageing: voltage drop after 10th alt. 25th cycle --- Max. allowed voltage drop (mV)......................: ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Continued ageing: voltage drop after 50th alt. 100th cycle --- Max. allowed voltage drop (mV)......................: ⎯ terminal 1 2 3 4 5 6 7 8 9 10 voltage drop (mV) Page 25 of 30 Ref. No.: CE10- LIE040101S 3.4 Table: marking P Requirement Comment Legible? Marking removable? easily Curling? Yes / No Yes / No Yes / No TABLE: Protection of supply cords(strain, twisting, abrasion) 5.2 Pull force (N) P Torque (Nm) Displacement (mm) Max displacement (mm) 0.25 1.2 2 60 P Table : protective earthing resistance 7.2.3 Test current 10 A Between Result (mΩ) Power supply grounding wire to 213 grounding pin Limited (mΩ) 500 12.3.2 TABLE: Endurance test Test cycles Test status Test voltage Test time Test status Test voltage Test time Result 1 Normal mode 237V 21Hr Disconnect supply 0V 3Hr Work normally, not any damage 2 Normal mode 237V 21Hr Disconnect supply 0V 3Hr Work normally, not any damage 3 Normal mode 237V 21Hr Disconnect supply 0V 3Hr Work normally, not any damage P Page 26 of 30 Ref. No.: CE10- LIE040101S 4 Normal mode 237V 21Hr Disconnect supply 0V 3Hr Work normally, not any damage 5 Normal mode 237V 21Hr Disconnect supply 0V 3Hr Work normally, not any damage 6 Normal mode 237V 21Hr Disconnect supply 0V 3Hr Work normally, not any damage 7 Normal mode 237V 21Hr Disconnect supply 0V 3Hr Work normally, not any damage 8 Normal mode 237V 21Hr Disconnect supply 0V 3Hr Work normally, not any damage 9 Normal mode 237V 21Hr Disconnect supply 0V 3Hr Work normally, not any damage 10 Normal mode 237V 21Hr Disconnect supply 0V 3Hr Work normally, not any damage 12 TABLE: Heating test under normal/abnormal operation conditions, thermocouples Condition P (12.4) 1.05 times rated power Remark test voltage (V).......................................... 237V --- t1 (°C) ....................................................... 24.6 --- t2 (°C) ....................................................... 26.4 --- temperature rise dT of part/at: DT (°C) Limited T (°C) Enclosure 01 32.7 --- Enclosure (near lamp) 36.8 --Page 27 of 30 Ref. No.: CE10- LIE040101S Internal wire near Terminals 46.3 90 Internal wire near connector 30.9 90 Mounting surface 01 32.8 90 Mounting surface (lamp irradiation) 31.5 90 Terminals 31.4 95 Remark: 10.2.1 TABLE: Insulation strength test P Test points Measured insulation Limited resistance Between To Live Enclosure >2 2MΩ Neutral Enclosure >2 2MΩ Live Neutral >2 2MΩ 10.2.2 TABLE: Electric strength after leakage test voltage applied between: P Test voltage (V) Breakdown (Yes/No) L/N and enclosure(wrapped foil) 1480 No breakdown Live and Neutral 1480 No breakdown Grounding and L/N 1480 No breakdown 10.3 insulation TABLE: leakage current Testing voltage: leakage current between: P Rated voltage Leakage (mA) (measured) Live and enclosure 0.055 -Max Leakage(mA) 0.5 Page 28 of 30 Ref. No.: CE10- LIE040101S Neutral and enclosure 0.062 0.5 22.15(13.2.1) TABLE: Ball pressure test temperature test from 11. temperature (°C) (°C) Test specimen Terminals 22.15(13.3.2) specimen Terminals P 31.4 125 impression diameter Limited diameter (∅mm) (∅mm) 0.01 2.0 TABLE: Ignition of non metallic material P Test temperature Test time (min) Result 720 1 No burning Page 29 of 30 Ref. No.: CE10- LIE040101S Photo document (EBO authenticate the photo on original report only) *** End of Report *** Page 30 of 30