Ref. No.: CE10- LIE040101S
Internal wire near Terminals
46.3
90
Internal wire near connector
30.9
90
Mounting surface 01
32.8
90
Mounting surface (lamp irradiation)
31.5
90
Terminals
31.4
95
Remark:
10.2.1
TABLE: Insulation strength test
P
Test points
Measured insulation
Limited
resistance
Between
To
Live
Enclosure
>2
2MΩ
Neutral
Enclosure
>2
2MΩ
Live
Neutral
>2
2MΩ
10.2.2
TABLE: Electric strength after leakage
test voltage applied between:
P
Test voltage
(V)
Breakdown
(Yes/No)
L/N and enclosure(wrapped foil)
1480
No breakdown
Live and Neutral
1480
No breakdown
Grounding and L/N
1480
No breakdown
10.3
insulation
TABLE:
leakage current
Testing voltage:
leakage current between:
P
Rated voltage
Leakage (mA)
(measured)
Live and enclosure
0.055
-Max Leakage(mA)
0.5