Download Workshop Manual - IRIZAR
Transcript
2.1 VALVES OPERATION 1. Solenoid 2. Sealing joints 3. Piston 4. O-Ring 5. Solenoid 6. Manual push-buttons 7. Regulators P- Power supply connector B- Cylinder outlet A- Cylinder outlet S- Discharge in the atmosphere from B R- Discharge in the atmosphere from A F- Discharge in the atmosphere from solenoid (1) G- Discharge in the atmosphere from solenoid (5) a- Passage to chambers b and c b- Chamber b- Chamber d- Passage to solenoid (1) e- Passage to solenoid (5) The 5-way 2-position electrovalve conveys the pneumatic air flow to the corresponding opening or closing chambers of the actuating cylinder, while connecting the inactivated cylinder chamber with the atmosphere. This valve is controlled by two solenoids (1 and 5) and there are also manual push-buttons (6) to be able to control it directly, in case of failure. OPERATION: Compressed air comes into the electrovalve through inlet P and, in the position shown in the figure, it goes out through B to the corresponding cylinder chamber. Air that comes through inlet P goes through passage a to chambers b and c and from there, it goes through passages d and e to the solenoid valves. Air remains 7