Download Dyn-Loc V Quick Start Guide
Transcript
Power shall NEVER be applied to the Dyn-Loc V during the wiring process. TORQUE Connector Wiring Options: Load Cell Belden 9534 (Item 3 in Cable table) Pin Wire Function 4 Red Excitation (+10 VDC) 16 Black Excitation Common 14 Green Input (+) 1 White Input (-) 2 Shield Install a jumper wire between each of the following pairs of pins: 5 – 6, 17 – 18, 3 – 13 In-Line Torque Sensor Belden 8761 (Item 1 in Cable table) Pin Wire Function 13 Clear Torque Sensor Input 25 Black Torque Sensor Input Common 12 Shield NOTE: Additional hardware may be required if using an In-Line torque sensor. If the torque sensor was provided by Dyne Systems, reference the associated system drawings; else, reference the torque sensor manufacturer’s documentation. Setup Parameters: The torque transducer must be properly configured in order to produce accurate readings. Power-up the DynLoc V. Then press the “SETUP” button to access all configuration parameters. Navigate to the following folder which contains all torque configuration parameters: “\\Dyn-Loc V\Control Variables\Torque” For the installed torque transducer, set the “Transducer Type” (Load Cell or Torque Sensor) as needed. This setting determines exactly which of the remaining settings need to be configured. For a load cell, get the full scale value (and units) and the sensitivity (MvV) from the load cell datasheet. Enter these values into the “Load Cell Full Scale Value”, “Setup Force Units”, and “Load Cell MvV” configuration parameters. NOTE: The units of the final torque reading can be different from the units used now during setup. Dyn-Loc V Quick Start Guide © Dyne Systems, Inc. Rev 1.0 Page 5 of 10