ATTENTION!
6.
Installation
6.1
Mechanical Installation
Danger of destruction of the EcoServ!
Operating the EcoServ in a non-suitable environment can
be destructible.
In case of unavoidable condensation moisture, remove the
condensation moisture before starting with a suitable
heater.
Ventilation
ND31 is only to be installed in an upright position. W hen installing
the compact device the power connection plugs must be at the
bottom.
W hen installing the 19” rack the air ventilator drawer must be
installed below the ND31. The area round the ND31 ventilation
outlets must not be blocked. The ND31 is not to be installed
above heat omitting devices.
Environment
The installation can only be performed at a location free of dust,
rust, metal chips, corroding or metal vapours, gases or liquids!
Condensation moisture is to be avoided. If it is not possible to
avoid the condensation if ND31 does not run please ensure that
the moisture is completely removed before setting up.
ND31 devices may not be used in areas classified as dangerous,
if they are not in approved housings and have not been tested.
6.2
Fuselage
The maximum voltage of the main supply is 230VAC. A
higher voltage could lead to the destruction of the
converter.
If the converter should be operated in the 400VAC mains, an
appropriate transformer has to be used.
Device ND31
3 phases
3202
3204
3207
3212
3 x 4 A inert
3 x 8 A inert
3 x 14A
inert
3 x 24 A
inert
If several drives are to be fused together, the sum of each device
has to be counted for the whole fuse.