MOV
Note: 1) The lock must also be fitted with the MOV supplied.
PSU
LOCK
12V DC PSU Positive, Link to
Door Relay Common
12V DC PSU Negative, Connect to
Negative Supply from Lock for both
Fail Safe and Fail Secure
Lock Relay N/C, Connect Positive
Supply form Lock Only if Fail Safe
Lock Relay N/O, Connect Positive
Supply from Lock Only if Fail Secure
Lock Relay Common,
Link to PSU Positive
Exit Button
Pair
(12VDC Shown)
Wiring Diagram For Ritekey 30-01
Not Used
N/C
N/O
COM
RETURN
EXIT B
DOOR C
Operating Voltage: 12 to 18 Volts AC or DC
Current Consumption: standby mode approx. 15ma
Maximum Draw: 130ma (not including door lock)
Door Relay: maximum rating 2 amps at the operating voltage
Service Temperature: +70 to –20 degrees C.
Specification
POWER
AC/DC
11-16V