997-060180-7
DAUGHTER BOARD TO FURNACE TO GENERIC AC WIRING (REFER TO UNITS I/O MANUAL FOR SPECIFICS
REQUIRED
OPTIONAL
1 STAGE AC WITH 1 STAGE FURNACE
THERMOSTAT
C
W2
R
W1
H
DAUGHTER
C
C
R
O/B
Y2
Y1
G
L
A+
BGND
OD
ID
GND
DX+
DX-
R
W
H
R
W
DEHUM
Y
G
L
Y
G
OD
OD
1 STAGE AC WITH VARIABLE SPEED FURNACE
FURNACE
C
AC
C
Y
L
THERMOSTAT
C
W2
R
W1
H
R
O/B
Y2
Y1
G
L
-
R
W
H
DX+
DX-
FURNACE
C
W2
2 STAGE AC WITH 2 STAGE VARIABLE SPEED FURNACE
AC
C
R
W1
DEHUM
O
Y1
Y/Y2
G
Y
G
L
A+
BGND
OD
ID
GND
OUTDOOR
SENSOR
DAUGHTER
C
C
W2
Y
L
OD
OD
THERMOSTAT
C
W2
R
W1
H
R
O/B
Y2
Y1
G
L
A+
BGND
OD
ID
GND
OUTDOOR
SENSOR
DAUGHTER
C
C
W2
R
W
H
R
W1
DEHUM
▬▬▬ R
Y2
Y1
L
OD
OD
*8MPV* "C" SERIES OR NEWER
*9MPV* "D" SERIES OR NEWER
AC
C
O
Y/Y2
Y1
G
Y2
Y
G
L
DX+
DX-
FURNACE
C
W2
OUTDOOR
SENSOR
*8MPV* "C" SERIES OR NEWER
*9MPV* "D" SERIES OR NEWER
DAUGHTER BOARD TO FURNACE TO GENERIC HP WIRING (REFER TO UNITS I/O MANUAL FOR SPECIFICS
REQUIRED
OPTIONAL
1 STAGE HP WITH 1 STAGE FURNACE
THERMOSTAT
C
W2
R
W1
H
DAUGHTER
C
C
R
O/B
Y2
Y1
G
L
-
R
W
H
1 STAGE HP WITH VARIABLE SPEED FURNACE
FURNACE
C
HP
C
R
W
DEHUM
W2
O
Y
G
L
A+
BGND
OD
ID
GND
DX+
DX-
OD
OD
O
Y
G
Y
L
THERMOSTAT
C
W2
R
W1
H
R
O/B
Y2
Y1
G
L
A+
BGND
OD
ID
GND
OUTDOOR
SENSOR
DAUGHTER
C
C
W2
R
W
H
R
W1
DEHUM
O
O
Y1
Y/Y2
G
Y
G
L
DX+
DX-
FURNACE
C
W2
OD
OD
2 STAGE HP WITH 2 STAGE VARIABLE SPEED FURNACE
HP
C
W2
O
Y
L
THERMOSTAT
C
W2
R
W1
H
R
O/B
Y2
Y1
G
L
A+
BGND
OD
ID
GND
OUTDOOR
SENSOR
DAUGHTER
C
C
W2
DX+
DX-
HP
C
▬▬▬ R
W2
R
W
H
R
W1
DEHUM
O
Y2
Y
G
L
O
Y/Y2
Y1
G
OD
OD
OUTDOOR
SENSOR
*8MPV* "C" SERIES OR NEWER
*9MPV* "D" SERIES OR NEWER
The "L" Output from the Heat Pump or A/C Unit can be wired to either the NAXA00201DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation.
The Outdoor Sensor can be hooked directly to the NAXA00201DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation.
A pigtail wiring harness is supplied with the NAXA00201DB Daughter Board for connection to its "L" input.
A pigtail wiring harness is supplied with the NAXA00201DB Daughter Board for connection to its "OD" inputs.
Notes:
FURNACE
C
W2
O
Y2
Y
L
*8MPV* "C" SERIES OR NEWER
*9MPV* "D" SERIES OR NEWER
DAUGHTER BOARD TO FANCOIL TO GENERIC AC WIRING (REFER TO UNITS I/O MANUAL FOR SPECIFICS)
REQUIRED
OPTIONAL
1 STAGE AC WITH VARIABLE SPEED FANCOIL + 2 STAGE ELECTRIC
HEAT
1 STAGE AC WITH 1 STAGE FANCOIL
DAUGHTER
C
C
THERMOSTAT
C
W2
R
W1
H
R
O/B
Y2
Y1
G
L
A+
BGND
OD
ID
GND
DX+
DX-
FANCOIL
C
R
W
R
W
Y
G
L
Y
G
OD
OD
AC
C
Y
L
THERMOSTAT
C
W2
R
W1
H
R
O/B
Y2
Y1
G
L
A+
BGND
OD
ID
GND
OUTDOOR
SENSOR
DAUGHTER
C
C
W2
R
W
H
Y
G
L
DX+
DX-
OD
OD
FANCOIL
C
W2
AC
C
R
W1
H
O
Y1
Y/Y2
G
Y
L
2 STAGE AC WITH VARIABLE SPEED FANCOIL + 2 STAGE ELECTRIC
HEAT
THERMOSTAT
C
W2
R
W1
H
R
O/B
Y2
Y1
G
L
A+
BGND
OD
ID
GND
OUTDOOR
SENSOR
DAUGHTER
C
C
W2
R
W
H
Y/Y2
Y
G
L
DX+
DX-
OD
OD
FANCOIL
C
W2
R
W1
H
AC
C
▬▬▬ R
O
Y/Y2
Y1
G
Y2
Y1
L
OUTDOOR
SENSOR
DAUGHTER BOARD TO FANCOIL TO GENERIC HP WIRING (REFER TO UNITS I/O MANUAL FOR SPECIFICS)
REQUIRED
OPTIONAL
1 STAGE HP WITH 1 STAGE FANCOIL + 1 STAGE ELECTRIC HEAT
THERMOSTAT
C
W2
R
W1
H
DAUGHTER
C
C
W2
R
O/B
Y2
Y1
G
L
A+
BGND
OD
ID
GND
Notes:
R
W
FANCOIL
C
HP
C
R
W
W2
O/B
Y
G
L
DX+
DX-
OD
OD
O
Y
G
Y
L
1 STAGE HP WITH VARIABLE SPEED FANCOIL +2 STAGE ELECTRIC
HEAT
THERMOSTAT
C
W2
R
W1
H
O/B
Y2
Y1
G
L
-
DAUGHTER
C
C
W2
R
FANCOIL
C
W2
R
W
H
R
W1
H
O/B
O
Y1
Y/Y2
G
Y
G
L
HP
C
W2
O
Y
L
2 STAGE HP WITH VARIABLE SPEED FANCOIL + 2 STAGE ELECTRIC
HEAT
THERMOSTAT
C
W2
R
W1
H
International Comfort Products, Inc.
4
R
O/B
Y2
Y1
G
L
-
A+
DX+
OD
A+
OUTDOOR
BDXOD
BSENSOR
GND
GND
OD
OD
ID
ID
GND
GND
The "L" Output from the Heat Pump or A/C Unit can be wired to either the NAXA00201DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation.
The Outdoor Sensor can be hooked directly to the NAXA00201DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation.
A pigtail wiring harness is supplied with the NAXA00201DB Daughter Board for connection to its "L" input.
A pigtail wiring harness is supplied with the NAXA00201DB Daughter Board for connection to its "OD" inputs.
OUTDOOR
SENSOR
DAUGHTER
C
C
W2
HP
C
R
W
H
R
W1
H
▬▬▬ R
W2
O/B
O
Y/Y2
Y1
G
O
Y2
Y
Y
G
L
DX+
DX-
FANCOIL
C
W2
OD
OD
L
OUTDOOR
SENSOR
482 06 5302 00
02/09