Download Installation Instructions / User`s Manual
Transcript
997-060180-7 DAUGHTER BOARD TO FURNACE TO GENERIC AC WIRING (REFER TO UNITS I/O MANUAL FOR SPECIFICS REQUIRED OPTIONAL 1 STAGE AC WITH 1 STAGE FURNACE THERMOSTAT C W2 R W1 H DAUGHTER C C R O/B Y2 Y1 G L A+ BGND OD ID GND DX+ DX- R W H R W DEHUM Y G L Y G OD OD 1 STAGE AC WITH VARIABLE SPEED FURNACE FURNACE C AC C Y L THERMOSTAT C W2 R W1 H R O/B Y2 Y1 G L - R W H DX+ DX- FURNACE C W2 2 STAGE AC WITH 2 STAGE VARIABLE SPEED FURNACE AC C R W1 DEHUM O Y1 Y/Y2 G Y G L A+ BGND OD ID GND OUTDOOR SENSOR DAUGHTER C C W2 Y L OD OD THERMOSTAT C W2 R W1 H R O/B Y2 Y1 G L A+ BGND OD ID GND OUTDOOR SENSOR DAUGHTER C C W2 R W H R W1 DEHUM ▬▬▬ R Y2 Y1 L OD OD *8MPV* "C" SERIES OR NEWER *9MPV* "D" SERIES OR NEWER AC C O Y/Y2 Y1 G Y2 Y G L DX+ DX- FURNACE C W2 OUTDOOR SENSOR *8MPV* "C" SERIES OR NEWER *9MPV* "D" SERIES OR NEWER DAUGHTER BOARD TO FURNACE TO GENERIC HP WIRING (REFER TO UNITS I/O MANUAL FOR SPECIFICS REQUIRED OPTIONAL 1 STAGE HP WITH 1 STAGE FURNACE THERMOSTAT C W2 R W1 H DAUGHTER C C R O/B Y2 Y1 G L - R W H 1 STAGE HP WITH VARIABLE SPEED FURNACE FURNACE C HP C R W DEHUM W2 O Y G L A+ BGND OD ID GND DX+ DX- OD OD O Y G Y L THERMOSTAT C W2 R W1 H R O/B Y2 Y1 G L A+ BGND OD ID GND OUTDOOR SENSOR DAUGHTER C C W2 R W H R W1 DEHUM O O Y1 Y/Y2 G Y G L DX+ DX- FURNACE C W2 OD OD 2 STAGE HP WITH 2 STAGE VARIABLE SPEED FURNACE HP C W2 O Y L THERMOSTAT C W2 R W1 H R O/B Y2 Y1 G L A+ BGND OD ID GND OUTDOOR SENSOR DAUGHTER C C W2 DX+ DX- HP C ▬▬▬ R W2 R W H R W1 DEHUM O Y2 Y G L O Y/Y2 Y1 G OD OD OUTDOOR SENSOR *8MPV* "C" SERIES OR NEWER *9MPV* "D" SERIES OR NEWER The "L" Output from the Heat Pump or A/C Unit can be wired to either the NAXA00201DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation. The Outdoor Sensor can be hooked directly to the NAXA00201DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation. A pigtail wiring harness is supplied with the NAXA00201DB Daughter Board for connection to its "L" input. A pigtail wiring harness is supplied with the NAXA00201DB Daughter Board for connection to its "OD" inputs. Notes: FURNACE C W2 O Y2 Y L *8MPV* "C" SERIES OR NEWER *9MPV* "D" SERIES OR NEWER DAUGHTER BOARD TO FANCOIL TO GENERIC AC WIRING (REFER TO UNITS I/O MANUAL FOR SPECIFICS) REQUIRED OPTIONAL 1 STAGE AC WITH VARIABLE SPEED FANCOIL + 2 STAGE ELECTRIC HEAT 1 STAGE AC WITH 1 STAGE FANCOIL DAUGHTER C C THERMOSTAT C W2 R W1 H R O/B Y2 Y1 G L A+ BGND OD ID GND DX+ DX- FANCOIL C R W R W Y G L Y G OD OD AC C Y L THERMOSTAT C W2 R W1 H R O/B Y2 Y1 G L A+ BGND OD ID GND OUTDOOR SENSOR DAUGHTER C C W2 R W H Y G L DX+ DX- OD OD FANCOIL C W2 AC C R W1 H O Y1 Y/Y2 G Y L 2 STAGE AC WITH VARIABLE SPEED FANCOIL + 2 STAGE ELECTRIC HEAT THERMOSTAT C W2 R W1 H R O/B Y2 Y1 G L A+ BGND OD ID GND OUTDOOR SENSOR DAUGHTER C C W2 R W H Y/Y2 Y G L DX+ DX- OD OD FANCOIL C W2 R W1 H AC C ▬▬▬ R O Y/Y2 Y1 G Y2 Y1 L OUTDOOR SENSOR DAUGHTER BOARD TO FANCOIL TO GENERIC HP WIRING (REFER TO UNITS I/O MANUAL FOR SPECIFICS) REQUIRED OPTIONAL 1 STAGE HP WITH 1 STAGE FANCOIL + 1 STAGE ELECTRIC HEAT THERMOSTAT C W2 R W1 H DAUGHTER C C W2 R O/B Y2 Y1 G L A+ BGND OD ID GND Notes: R W FANCOIL C HP C R W W2 O/B Y G L DX+ DX- OD OD O Y G Y L 1 STAGE HP WITH VARIABLE SPEED FANCOIL +2 STAGE ELECTRIC HEAT THERMOSTAT C W2 R W1 H O/B Y2 Y1 G L - DAUGHTER C C W2 R FANCOIL C W2 R W H R W1 H O/B O Y1 Y/Y2 G Y G L HP C W2 O Y L 2 STAGE HP WITH VARIABLE SPEED FANCOIL + 2 STAGE ELECTRIC HEAT THERMOSTAT C W2 R W1 H International Comfort Products, Inc. 4 R O/B Y2 Y1 G L - A+ DX+ OD A+ OUTDOOR BDXOD BSENSOR GND GND OD OD ID ID GND GND The "L" Output from the Heat Pump or A/C Unit can be wired to either the NAXA00201DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation. The Outdoor Sensor can be hooked directly to the NAXA00201DB Daughter Board or the TSTAT0406 or TSTAT0407 Thermostats for proper operation. A pigtail wiring harness is supplied with the NAXA00201DB Daughter Board for connection to its "L" input. A pigtail wiring harness is supplied with the NAXA00201DB Daughter Board for connection to its "OD" inputs. OUTDOOR SENSOR DAUGHTER C C W2 HP C R W H R W1 H ▬▬▬ R W2 O/B O Y/Y2 Y1 G O Y2 Y Y G L DX+ DX- FANCOIL C W2 OD OD L OUTDOOR SENSOR 482 06 5302 00 02/09