Download Linear Actuator User Manual
Transcript
A99UE13-1307 • The upper and lower limit switches are operated normally. • The motor stops when the extension tube reaches upper and lower limit switch positions. If the linear actuator fails to meet any of these conditions, please repeat steps 2.2 to 2.4 until the above mentioned clauses are met 2.7. The entire installation is finished only if steps 2.1 to 2.6 are executed successfully. 2.8. HIWIN Mikrosystem Corp. cannot take any responsibility for any injuries and/or damages caused as a result of not complying with the clauses of this section. 3. Note: 3.1. Don't use this product to make current transient inversion. If you try to backwardly move the present extension tube that forwardly moves, you must stop the motor and apply the reverse current to make backward movement. On the contrary, if you want the extension tube backward moved to forward, the way to supply current will be the same as mentioned above. 3.2. Don't use this product with a radial load (Please refer to figures and tables below.) because an actuator more appropriately applies to take the axial load. If there is product damage, accident or personal injury caused by improper load, we will not take any legal responsibility. 3.2.1 LA Series Load Load Actuator Axial Direction 9