Download Catalog / Manual
Transcript
SPA Trouble Shooting The above faults should be handled by qualified electrician. CONTENTS OPERATION INSTRUCTION. . . . . . . . . . . . . . . . . . . . . . . 1 S P E C I F I C AT I O N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 F E AT U R E S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 SPA LOCATION AND INSTALLATION ................ 10 USE INSTRUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 GENERAL MAINTENANCE. . . . . . . . . . . . . . . . . . . 15 S PA T R O U B L E S H O O T I N G . . . . . . . . . . . . . . . . . . . . 1 6 Symptom Probable Cause Solution 1.Leakage circuit interrupter tripped or in OFF position. Spa system 2.Electrical cord or transformer cord not plugged in. No electricity 3.The Control box and Control panel not connected well. 4.The fuse in the control box was broken Control panel failure 1.Reset the Leakage circuit interrupter. 2.Plug in the electrical or transformer cord. 3.Connect the wires and fix the screws. 4.Change the fuse (1.25A). 1.Power supply g o t 1.Cut off the power supply interfered,programme was in it,and restart. disorder. 2.Change the IC AT89C2051. 2.IC AT89C2051 damaged. 1.Improper water level. 2.The connection with water level Spa not heating sensor loose or break. 3.Set improper heating temperature properly or time. 4.Overheating protection device tripped or heating element damaged. 5.The relay controlling the air blower damaged. 6.AT89C2051 damaged. 1.Add water to normal level. 2.Check the wiring. 3.Make sure the set temperature is higher than surrounding temperature, and the setting time is not ZERO. 4.Check the overheating protection device or heating elements. 5.Change the Relay controlling the heater. 6.Change the IC AT89C2051 1.Low water level. 2.Connections to Water Level sensor are loose or break off. No whirlpool 3.The relay controlling the whirlpool pump damaged. 4.Whirlpool pump damaged. 1.Add water to normal level. 2.Check the wiring. 3.Change the relay controlling the whirlpool pump. 4.Change the new whirlpool pump. 1.Suction or discharge line Jet pressure not partially blocked. strong enough 2.Dirty filter cartridge. 3.Spa jets improperly adjusted. 1.Check the whirlpool pump and remove the debris. 2.Clean the suction or filter cartridge. 3.Reset jets for desired output. 1.Low water level. 2.The connection with water No air bubble level sensor loose or break. 3.The relay controlling the air blower damaged. 4.Air blower damaged. 1.Check the water level. 2.Check the wiring. 3.Replace the relay controlling the air blower. 4.Replace the air blower. 17