Appendix C: Bypass Specifications Bypass Control Register Bit Definitions Bit Field Bypass Timer Configuration Register F2 Bit Field Name Value 2:0 Timer value 000 = 0 second, timer immediately expired 001 = 1 second 010 = 2 seconds 011 = 4 seconds 100 = 8 seconds 101 = 16 seconds 110 = 32 seconds 111 = 64 seconds Note: This is a write only field. Upon reads these bit values are undefined. A Timer value of 1 to 7 is required to be written before expiration of the hardware timer. When the timer expires, all segments which have been enabled in bits 2:0 of Power ON state Bypass Control Status Register set relays closed to form bypass segments. It is the responsibility of the software to keep track of the time to ensure writes to this register occur no greater than TimerValueInSeconds / 2. A write of the timer value will automatically reset the expiration timer and set it to the value expressed in bit 2:0. Copyright © 2011 NEXCOM International Co., Ltd. All Rights Reserved. 91 Name Value 3 Not used No activity taken if written, value is undetermined and not needed on read operation. 4 Not used No activity taken if written, value is undetermined and not needed on read operation. 5 Not used No activity taken if written, value is undetermined and not needed on read operation. 6 Not used No activity taken if written, value is undetermined and not needed on read operation. 7 Timer expired Read only bit: 0 = Timer has not expired 1 = Timer has expired Note: A read operation on Bypass Timer Configuration Register should not cause the timer value to refresh. NSA 5130 User Manual