contact closures can communicate between two Zephyr Xstreams. By grounding an
input on the local Xstream, you would therefore cause current to flow into the
corresponding output, at the far end unit. These can also be used for local control
and to monitor local status see section 10.5 has additional information on the use of
this port.
Z
ZEPHYR CLASSIC VS. XSTREAM COMPARISON!
The original Zephyr has only four inputs and outputs numbered 0- 3 while the
Xstream has 8 inputs 0- 7. The four inputs and outputs of the Zephyr will
communicate with the first four inputs and outputs of the Xstream (i.e. 0- 3)
PIN
FUNCTION
1
2*
3*
4*
5*
6
7
8
9
10
11
12
13
14*
15*
16*
17*
18
19
20
21
22
23
24
25
+5 Volts DC 400 mA max
Output 0
Output 1
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
No Connection
No Connection
No Connection
No Connection
Input 0
Input 1
Input 2
Input 3
Input 4
Input 5
Input 6
Input 7
Not Connected
Not Connected
Not Connected
Ground
*
These pins are compatible with
the corresponding
input/outputs of the Zephyr.
NOTE: Pin 1 is connected directly to the +5 volt power supply. Failure to limit
current draw on this pin could cause hardware damage or system instability.