FREESPACE TURBO 2. Connect the cable pairs to the terminals in the Power Box. 3. Connect the cable pairs to the terminals in the Power Junction Box. 4. Verify visually that the Power Cable pairs have been correctly terminated at: • The Power Box • The Power Junction Box 5.7.5 MOUNT POWER JUNCTION BOX Use the pre-drilled mounting holes and lugs supplied to attach the Power Junction Box to the location specified in the site survey. Wiring in the Power Junction Box corresponds wire-to-wire on both sides of the box. The dimensions of the Power Junction Box are 4.75" x 3" x 2.25" (12 x 8 x 5.5 cm). WARNING Do not drill holes in the Power Junction Box, as doing so will compromise the box’s weatherproof properties. Figure 5-8. Power Junction Box. 5.7.6 MOUNT FIBER PATCH BOX Use the mounting lugs supplied to attach the Fiber Patch Box to the location specified in the site survey. It is good practice to mount the box with cable openings downwards to minimize the potential for water leakage. The Fiber Patch Box measures 5" x 5" x 3" (13 cm x 13 cm x 7.5 cm). 45