Download CONTROLLOGIX CONTROLLERS

Transcript
ControlLogix Selection Guide
9
Digital dc Input Modules
Cat. No.
Voltage,
Number of On-State
Operating
Inputs
Input, Nom. Voltage
Removable
Input Delay Current,
Current,
Current,
Terminal
Backplane Backplane Power
Time, ON
On-State
On-State
Off-State
Block
Current
Current
Dissipation,
to OFF
Input, Min. Input, Max. Input, Max. Housing
(mA) at 5V (mA) at 24V Max.
10...31.2V dc
2 ms
hardware +
filter time (0,
1, 2, 9, or 18
ms)
2.0 mA @ 10V 10 mA @
dc
31.2V dc
10...30V dc
4 ms
hardware +
filter time (0,
1, 2, 9, or 18
ms)
2 mA @ 10V
dc
2 mA @ 10 V
dc
5.5 mA @ 55V 2 mA @ 10V
dc
dc
1756-IB16
16
12/24V dc
sink
1756-IB16D
16
diagnostic
12/24V dc
sink
1756-IB16I
16
individually
isolated
12/24V dc
sink/source
10...30V dc
4 ms
hardware +
filter time (0,
1, 2, 9, or 18
ms)
16
individually
1756-IB16ISOE= isolated;
sequence of
events
24/48V dc
sink/source
10...55V dc
50 μs
hardware +
filter time
(0...50 ms)
1756-IB32
32
12/24V dc
sink
10...31.2V dc
420 μs + filter
time (0, 1, 2, 2 mA
9, or 18 ms)
1756-IC16
16
48V dc
sink
30...60V dc
4 ms
hardware +
filter time (0,
1, 2, 9, or 18
ms)
1756-IG16
16 (8
5V dc
points/commo
TTL source
n)
1756-IH16I
16
individually
isolated
1756IH16ISOE=
1756-IV16
1756-IV32
1756-TBNH
1756-TBSH
100 mA
2 mA
5.1 W @ 60 °C
13 mA @ 30V
1.5 mA/point
dc
1756-TBCH
1756-TBS6H
150 mA
3 mA
5.8 W @ 60 °C
10 mA @ 30V
1.5 mA
dc
1756-TBCH
1756-TBS6H
100 mA
3 mA
5 W @ 60 °C
1.5 mA
1756-TBCH
1756-TBS6H
275 mA
2 mA
5.5 W @ 60 °C
5.5 mA
1.5 mA
1756-TBCH
1756-TBS6H
120 mA
2 mA
6.2 W @ 60 °C
2 mA @ 30V
dc
7 mA @ 60V
dc
1.5 mA
1756-TBNH
1756-TBSH
100 mA
3 mA
5.2 W @ 60 °C
4.5...5.5V dc
.25 ms
hardware +
filter time (0,
1, 2, 9, or 18
ms)
—
—
4.1 mA
1756-TBNH
1756-TBSH
110 mA
2 mA
1.4 W @ 60 °C
125V dc
sink/source
90...146V dc
6 ms
hardware +
filter time (0,
1, 2, 9, or 18
ms)
1 mA @ 90V
dc
3 mA @ 146V
0.8 mA
dc
1756-TBCH
1756-TBS6H
125 mA
3 mA
5 W @ 60 °C
16
individually
isolated;
sequence of
events
125V dc
sink/source
90...140V dc
75 μs
hardware +
filter time
(0...50 ms)
1.15 mA @
90V dc
1.85 mA @
140V dc
1756-TBCH
1756-TBS6H
275 mA
2 mA
5.5 W @ 60 °C
16
12/24V dc
source
10...30V dc
2 ms
hardware +
filter time (0,
1, 2, 9, or 18
ms)
2.0 mA @ 10V 10 mA @ 30V
1.5 mA
dc
dc
1756-TBNH
1756-TBSH
110 mA
2 mA
5.41 W @ 60
°C
32
12/24V dc
source
10...30V dc
2 ms
hardware +
filter time (0,
1, 2, 9, or 18
ms)
2 mA @ 10V
dc
1756-TBCH
1756-TBS6H
120 mA
2 mA
4.1 W @ 60 °C
1.5 mA
0.3 mA
3.5 mA @ 30V
1.5 mA
dc
=If you use 1756-IB16ISOE or 1756-IH16ISOE modules in a remote rack, you must use a 1756-SYNCH SynchLink module to coordinate system time.
1756-SG001J-EN-P -- September 2007