Download CONTROLLOGIX CONTROLLERS
Transcript
ControlLogix Selection Guide 9 Digital dc Input Modules Cat. No. Voltage, Number of On-State Operating Inputs Input, Nom. Voltage Removable Input Delay Current, Current, Current, Terminal Backplane Backplane Power Time, ON On-State On-State Off-State Block Current Current Dissipation, to OFF Input, Min. Input, Max. Input, Max. Housing (mA) at 5V (mA) at 24V Max. 10...31.2V dc 2 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 2.0 mA @ 10V 10 mA @ dc 31.2V dc 10...30V dc 4 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 2 mA @ 10V dc 2 mA @ 10 V dc 5.5 mA @ 55V 2 mA @ 10V dc dc 1756-IB16 16 12/24V dc sink 1756-IB16D 16 diagnostic 12/24V dc sink 1756-IB16I 16 individually isolated 12/24V dc sink/source 10...30V dc 4 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 16 individually 1756-IB16ISOE= isolated; sequence of events 24/48V dc sink/source 10...55V dc 50 μs hardware + filter time (0...50 ms) 1756-IB32 32 12/24V dc sink 10...31.2V dc 420 μs + filter time (0, 1, 2, 2 mA 9, or 18 ms) 1756-IC16 16 48V dc sink 30...60V dc 4 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 1756-IG16 16 (8 5V dc points/commo TTL source n) 1756-IH16I 16 individually isolated 1756IH16ISOE= 1756-IV16 1756-IV32 1756-TBNH 1756-TBSH 100 mA 2 mA 5.1 W @ 60 °C 13 mA @ 30V 1.5 mA/point dc 1756-TBCH 1756-TBS6H 150 mA 3 mA 5.8 W @ 60 °C 10 mA @ 30V 1.5 mA dc 1756-TBCH 1756-TBS6H 100 mA 3 mA 5 W @ 60 °C 1.5 mA 1756-TBCH 1756-TBS6H 275 mA 2 mA 5.5 W @ 60 °C 5.5 mA 1.5 mA 1756-TBCH 1756-TBS6H 120 mA 2 mA 6.2 W @ 60 °C 2 mA @ 30V dc 7 mA @ 60V dc 1.5 mA 1756-TBNH 1756-TBSH 100 mA 3 mA 5.2 W @ 60 °C 4.5...5.5V dc .25 ms hardware + filter time (0, 1, 2, 9, or 18 ms) — — 4.1 mA 1756-TBNH 1756-TBSH 110 mA 2 mA 1.4 W @ 60 °C 125V dc sink/source 90...146V dc 6 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 1 mA @ 90V dc 3 mA @ 146V 0.8 mA dc 1756-TBCH 1756-TBS6H 125 mA 3 mA 5 W @ 60 °C 16 individually isolated; sequence of events 125V dc sink/source 90...140V dc 75 μs hardware + filter time (0...50 ms) 1.15 mA @ 90V dc 1.85 mA @ 140V dc 1756-TBCH 1756-TBS6H 275 mA 2 mA 5.5 W @ 60 °C 16 12/24V dc source 10...30V dc 2 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 2.0 mA @ 10V 10 mA @ 30V 1.5 mA dc dc 1756-TBNH 1756-TBSH 110 mA 2 mA 5.41 W @ 60 °C 32 12/24V dc source 10...30V dc 2 ms hardware + filter time (0, 1, 2, 9, or 18 ms) 2 mA @ 10V dc 1756-TBCH 1756-TBS6H 120 mA 2 mA 4.1 W @ 60 °C 1.5 mA 0.3 mA 3.5 mA @ 30V 1.5 mA dc =If you use 1756-IB16ISOE or 1756-IH16ISOE modules in a remote rack, you must use a 1756-SYNCH SynchLink module to coordinate system time. 1756-SG001J-EN-P -- September 2007