Download Telair Generators
Transcript
GB Always fit a 100 A fuse onto the positive cable connecting the generating set to the positive pole of the battery. 4.5 Electric Load connection To connect loads to the power generating set, use a three-pole cable up to the applicable standards in force. The correct cross section is shown in Table 1. Table 1 2 Model Sect. mm line 230 V Cable leng. Lgth < 6 m Cable leng Lgth. > 6 m 4010B 4 10 16 LINE CONNECTION 230 V BATTERY CONNECTION For connection to the 230V input line, the generating set is equipped with a special terminal strip (Fig.13 Ref.1) to which the cables must be connected. Vers. 002 Use the special cable outlet (Fig.11 Ref.1) to prevent water seeping into the generating set. Although the generating set is equipped with a special internal thermal cut-out to cut power delivery in the event of overload or short circuits (Fig.13 Ref.5), it is advisable to install (in the vehicle control panel) a thermomagnetic cut-out switch, suitably set to stop power delivery to the various users when current absorption exceeds 16,5 Amp. If the generating set thermal cut-out switch has been operated, press the button (Fig. 13 Ref. 5) to restore closed circuit and power delivery conditions. Carefully check the position of the line connection for picking up 230 Volt current. Wrong connection could damage the generating set irreparably or create dangerous short circuits. Energy 4010 B 11