Introduction to Control Functions For further details on each function, see chapter 1, “Explanation of Functions” in the CX2000 User’s Manual (IM 04L31A01-01E) provided on the accompanying CD-ROM. Control Types Control Mode The following four control modes are available (three types of control plus analog retransmission) and can be set for each control loop. The mode can be specified for each control output terminal block (two loops per block, see page 7). However, single loop control can be specified on the control output terminal block for loops 5 and 6. Single-loop control SP PID OUT Cascade control PV1 PV SP Loop control with PV switching PV2 PID PV1 PV2 SP PID OUT PID OUT PV: Process value SP: Target setpoint OUT: Control output Analog retransmission Output comes from the control output channels per the results of the specified equation. Control Operation Mode You can specify either of the following control operation modes for each control loop. However, program control operation can be specified only on models with the program control option. • Fixed-point control (program control OFF): Set the SP locally or use remote input • Program control operation: Set the SP locally or use program patterns PID Control Function Control Computation Types and Control Output Format You can select from time proportional PID control (voltage pulse/relay output), continuous PID control (current output), or On/Off control (relay output). Control Direction You can select the direction in which OUT changes according to the polarity of the deviation between the SP and the PV. • Reverse action (PV > SP: OUT decreases, PV < SP: control output increases) • Direct action (PV > SP: OUT increases, PV < SP: control output decreases) PID Control Mode You can select the change in the operation when the SP is changed. • Follow-up: Controlled so that the output reaches the new SP quickly • Fixed-point: Suppresses sensitive reaction of the output to change to the new SP PID Control Method One of the following methods is automatically selected depending on the PID control mode and the control operation mode. • PV derivative type: Control method in which the control output is kept from changing radically when the SP is changed by a great amount • Deviation derivative type: Control method in which fast response to follow the SP is emphasized Control Parameter (“PID Parameter” in the Settings) You can set up to eight groups of control parameter sets for each loop. Control parameters include SP, PID constant, control output limiter, manual reset value, control direction, and preset output. 4 IM 04L31A01-02E