Download User Manual
Transcript
B-3 Parameter Information Table B.1 (cont.) Parameter List Group Parameter Description Parameter Number Display Units Scale Factor Minimum Maximum Default Setting Slow Speed with Braking Basic Setup (cont.) Advanced Setup Slow Speed Select 44 — — Slow Accel Current 46 % FLC 1 0 450 0 Slow Running Current 47 % FLC 1 0 450 0 Braking Current 48 % FLC 1 0 400 0 Low, High High Dual Ramp 29 — — Ramp Time #2 No, Yes No 32 Seconds 1 0 30 10 Initial Torque #2 33 % LRT 1 0 90 70 Undervolt Level 52 % Line Voltage 1 0 99 0 (Off) Undervolt Delay 53 Seconds 1 0 99 0 Overvolt Level 54 % Line Voltage 1 0 199 0 (Off) Overvolt Delay 55 Seconds 1 0 99 0 Jam Level 56 % FLC 1 0 999 0 (Off) Jam Delay 57 Seconds 10 0.0 10.0 0 Unbalance Level 58 % 1 0 25 0 (Off) Unbalance Delay 86 Seconds 1 0 99 0 Rebalance 59 — — Underload Level 60 % FLC 1 0 99 0 (Off) Underload Delay 61 Seconds 1 0 99 0 Phase Reversal 62 — — Starts per Hour 63 — —1 0 99 0 (Off) Restart Attempts 64 — 1 0 5 2 Restart Delay 65 Seconds 1 0 60 0 ETM Reset 15 — — Off, On Off Parameter Management 17 — — Ready, Default Init. Recll Frm EE,Store In EE Ready Off, On Off Off, On Off User Setting