Spinmaster FFC-2000 - Reference manual page 1 of 1 1. Introduction Ever since the introduction of Nuclear Magnetic Resonance (NMR), there has been great interest in relaxation phenomena, including their field dependence. Starting in the fifties, mechanical methods for shuffling a sample between locations with different magnetic fields had been used to acquire T1 dispersion profiles (plots of longitudinal relaxation time as a function of field intensity at a constant temperature). In such methods, a high field magnet is used to prepolarize the sample in order to boost signal intensity; thereafter, the sample is allowed to relax within a second magnet whose field can be set to any desired value. However, since mechanical shuffling methods were found unsuitable for fast relaxing samples with T1 values below 100 ms, it became evident that faster - and more flexible - electronic methods would have to be applied. This implied the development of low-inductance, air-coil magnets and power supplies capable of switching the field electronically to any desired value in a short span of few milliseconds while maintaining the high field stability and homogeneity required by NMR at the same time. The approach, known as Fast Field Cycling, has enjoyed success in several academic laboratories in the past. Nowadays, this technique is looked upon as an important analytical tool for NMR research and material characterization, both in industrial and academic environments. Stelar’s Spinmaster FFC-2000 Relaxometer is the first commercially available system aimed to attain this purpose. As a research-grade instrument, SPINMASTER FFC-2000 provides the User with both a set of pre-programmed experiments and a lot of freedom in designing one’s own pulse & field sequences. The classical approaches to measure T1 at variable field strengths are the pre-polarization sequence (PP), suitable at low relaxation fields, and the non-polarized sequence (NP), usable at higher Brlx (Relaxation field). Basic prepolarized sequence BACQ BPOL BRLX BRLX PW90 Transmitter BACQ B=0 PW90 Transmitter Acquisition Acquisition TPOL Basic nonpolarized sequence SWT TAU SWT STIM TPOL SWT TAU SWT STIM The upper trace shows the switching of field values between the fixed polarization field Bpol, the variable relaxation field Brlx and the fixed detection field Bacq. The next trace shows the transmitter gate with the RF pulse (of width PW90) followed, after a small delay, by the FID acquisition. The last trace shows the times involved: TPOL SWT TAU polarization delay magnet switch-off/on time variable relaxation interval For every given Brlx, the signal is measured as a function of the time TAU, keeping the other times constant. This time dependence is due exclusively to the relaxation in the field Br. Similar definitions apply to the NP (non polarized) sequence. Copyright © Stelar s.r.l 2001