250-0246r2_readers.qxd 12 6/7/01 10:51 AM Page 12 Installation Power lead connections Connect the AC line power leads to TB501 terminals L1 and L2, or to a double-throw, single-pole master power switch (recommended). Dynamic brake resistor connections If you plan to use dynamic braking to stop the motor, you must connect a dynamic brake resistor across the DB+ and DBterminals on the PCB as shown in Figure 3. The dynamic brake resistor reduces the voltage across the bus capacitors (C503 and C504) when they reach their maximum voltage rating. This occurs when the motor regenerates voltage back to the drive. Bus capacitor maximum voltage ratings are 400 VDC for 240 VAC drives, and 200 VDC for 115 VAC drives. For more information on dynamic braking, as well as selecting dynamic brake resistor values, refer to the Dynamic Braking section on page 23.