Based on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of a radiation emissions measurement is +4.0 dB. 8.3 Test Equipment List and Details Equipment Manufacturer Model No. Serial No. Last Cal Calibration Period Spectrum Analyzer Agilent E4446A US44300399 2013/04 1 year EMI Test Receiver R&S ESCI 1166.595K03 2013/04 1 year Pre Amplifier MITEQ N/A AFS4200102650-4210P-42 2013/04 1 year Bilog Antenna EMCO 3142C 920250 2013/04 1 year Horn Antenna R/S HF906 100039 2013/04 1 year Dipole Antenna Com-Power AD-100 041000 2013/04 1 year Signal Generator IFR 2032 203002/100 2013/04 1 Year 8.4 Test Procedure 1. Please refer to ETSI EN 300 328 (V1.7.1) clause 5.3 for the test conditions. 2. Please refer to ETSI EN 300 328 (V1.7.1) clause 5.7.5 for the measurement methods. 8.5 Test Configuration Below 1GHz Report No.: BCT13HR-1419E -2 Page 18 of 35