Download Maris ECDIS900 Technical Manual, EN
Transcript
UPS Performances • • • • • • Technology High-Frequency Line-Interactive Automatic voltage regulation Booster/Fader Output voltage waveform Sinewave Input voltage tolerances 160V/294V, adjustable to 150V/294V via supplied UPS-Driver software Frequency 50/60 Hz, auto-select Output voltage on battery power 230V (adjustable to 200/220/240V via supplied UPSDriver software) Features • • • • • • Automatic battery test Weekly (interval adjustable via supplied UPS-Driver software) Hot swappable batteries Cold start Deep discharge protection UPS-Driver for Windows® Settings: Input voltage tolerances, Sensitivity, Battery test, ON/OFF conditions Standards • • • • • • • • • Safety EN 50091-1-1/EN60950(RD),IEC 60950,Tüv GS-Mark, IEC 60 945 Electromagnetic compatibility EN 50091-2,EN 50022/B,IEC 62040-2,IEC 61000-3-2,IEC 61000-3-3, IEC 60 945 Design, production and services ISO 9001 Marking CE, TÜV GS-Mark, DnV Dimensions and weight Tower dimensions (HxWxD in mm) 150x237x415 Tower weights (in kg) 10.5 SPECIFICATIONS OF THE MGE UPS SYSTEMS, MODEL PULSAR EXTREME C RACK MARINE 1500. • • • • • Power (VA / Watts) at full load 1500 VA / 1050 W # of receptacles 6 w/ 2 switchable Part Number UPS + EMC filter 66 353 + 5102174900 Part number extra battery module 66 356 Part number alarm card (dry contacts) 66 246 Features Benefits • • • 44 True On Line Technology (1) Utility power is constantly conditioned within very tight limits without draining the batteries Smart battery management The built-in microprocessor optimizes the charging sequence to prolong battery lifetime Complete front panel display Check the battery or capacity levels for peace of mind. Get valuable information on the UPS status and operating parameters.