Gas Conversion and Specifications
Gas Specifications
- Australia / New Zealand
Natural Gas
LP Gas (Propane)
Ø 2.45 mm
Ø 1.50 mm
0.30
0.20
Main Burner
Ø 2.10 mm
Ø 1.30 mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully open
Fully open
Main Burner
Ø 2.60 mm
Ø 1.60 mm
Pilot Burner
0.35
0.23
Fully open
Fully open
1.13 - 3.40 kPa
2.75 - 4.50 kPa
0.95 kPa (*)
2.6 kPa (*)
Natural Gas
(G20)
Propane
(G31)
Ø 2.30 mm
Ø 1.40 mm
0.30
0.20
Main Burner
Ø 2.10 mm
Ø 1.30 mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully open
Fully open
Main Burner
Ø 2.60 mm
Ø 1.60 mm
Pilot Burner
0.35
0.23
Fully open
Fully open
Supply Pressure
20 mbar
30 / 37 mbar
Operating Pressure
9.5 mbar
26 mbar
Open Burner
Griddle
Oven
Main Burner Injectors
Pilot Burner ('PF' Option Only)
Burner Aeration Setting
Supply Pressure
Operating Pressure
Gas Regulator Cap Screw
- CE Only
Appliance Classification
Category:
Flue Type:
Open Burner
Griddle
Oven
II2H3P (20, 30 / 37).
A1.
Main Burner Injectors
Pilot Burner ('PF' Models Only)
Burner Aeration Setting
Gas Regulator Cap Screw
*
The burner operating pressure is to be measured at the manifold test point with two
burners operating at the ‘High’ setting. The operating pressure is ex-factory set through
the appliance regulator and is not to be adjusted, apart from when carrying out gas
conversion, if required. (Refer to the ‘Gas Conversion’ section for details).
27