FAULT
POSSIBLE CAUSE
REMEDY
ELEMENT NOT WORKING
Element faulty (blown).
(Refer fault diagnosis 6.1.9)
Replace.
(Refer service section 6.3.15)
NO THERMOSTAT HEATING
INDICATOR
Indicator faulty.
(Refer fault diagnosis 6.1.12)
Replace.
(Refer service section 6.3.3)
ROAST TIMER (180 MINUTE)
WILL NOT TIME DOWN
Roast ’n’ Hold switch not depressed.
Depress switch. Switch will
illuminate.
No power to timer / timer faulty.. Correct electrical fault / replace
(Refer fault diagnosis 6.1.13) timer.
(Refer service section 6.3.8)
NO HOLD INDICATOR
HOLDING TEMPERATURE
INCORRECT
DOOR DOES NOT CLOSE
DOOR SEAL LEAKS
Revision 1/F3508
‘Roast ‘n Hold’ switch faulty.
(Refer fault diagnosis 6.1.13)
Replace.
(Refer service section 6.3.4)
Faulty indicator.
(Refer fault diagnosis 6.1.14)
Replace.
(Refer service section 6.3.3)
Faulty timer.
(Refer fault diagnosis 6.1.14)
Replace.
(Refer service section 6.3.8)
Hold thermostat set temperature incorrect.
Adjust to correct temperature.
(Refer service section 6.4.5)
Hold thermostat faulty.
(Refer fault diagnosis 6.1.15)
Replace.
(Refer service section 6.3.10)
Tray in way of door.
Correctly position tray in rack.
Door seal obstruction.
Correctly install door seal.
(Refer service section 6.3.20)
Door handle installed
incorrectly.
Fit correctly.
(Refer installation section)
Door catch setting incorrect.
Adjust.
(Refer service section 6.4.3)
Door pivot bushes / pins worn.
Replace.
(Refer service section 6.3.21)
Door seal damaged.
Replace.
(Refer service section 6.3.20)
Door seal incorrectly fitted.
Correctly install door seal.
(Refer service section 6.3.20)
Door catch setting incorrect.
Adjust.
(Refer service section 6.4.3)
Door pivot bushes / pins worn.
Replace.
(Refer service section 6.3.21)
Door catch striker plate worn.
Replace.
(Refer installation instructions—Door handle installation)