Download HW User Manual
Transcript
InfiniBand FDR Switch Platform Hardware User Manual Table 17 - Switch Specification SX6506-[3R, NR] Physical Total Power Consumption FDR FDR Max Heat Output Temperature Humidity Typical Passive: 1241W Active: 1488W (includes QSFP at 1.5W) Optical: 1521W (includes QSFP at 1.7W) Maximum Passive: 1314W Active: 1593W (includes QSFP at 1.7W) Optical: 1643W (includes QSFP at 2.0W) 5,606 BTUs/hr Operating: 0° to 45° Celsius Non-operating: -40° to 70° Celsius Operating: 10% - 85% non-condensing Protocol Support Speed Protocol Management Data Rate QoS InfiniBand: Auto-negotiation of 56Gb/s,40Gb/s, 20Gb/s, 10Gb/s MLNX-OS and baseboard, performance, and device management agents for full InfiniBand in-band management. 56Gb/s per port 8 InfiniBand virtual lanes for all ports Regulatory Compliance Safety US/Canada: cTUVus certificate International: CB report and certificate Russia: GOST-R certificate Argentina: S-mark certificate DoC BSMI certificate (for the power supply only) EMC (Emissions) CE EMC & safety report and certificate USA: FCC part 15 class A Canada: ICES-003 class A Australia / New Zealand: AS/NZS CISPR 22 class A Japan: VCCI, Class A Australia C-Tick certificate Environmental EU: IEC 60068-2-64: Random Vibration EU: IEC 60068-2-29: Shocks, Type I / II EU: IEC 60068-2-32: Fall Test Acoustic Mellanox Technologies 76 DbA ISO 7779 ETS 300 753 83