User Diagnostics Table 5-1 User Diagnostics Symptom Check Further Checks and Corrections Output not adjustable. Is unit in current limit mode? (Red Current Mode LED turned on.) Turn current knob clockwise to increase current limit. Reduce load if current is at maximum. See page 3–6. Is unit in remote mode? (Green REM LED turned on.) If using remote analog control, check your analog programming source (Chapter 4). If not, refer to your digital interface manual. Is unit at maximum voltage or current limit? Reduce load for lower voltage or current requirement. Is unit at current limit? Increase current limit setting or reduce load. See page 3–6. Is input voltage within specified range? Connect to appropriate AC voltage source. See page 2–6. Are sense lines connected? See page 2–9 and page 2–18. Is unit under remote analog control? Ensure that program source is stable. Internal circuit. See your service technician. Internal circuit. See your service technician. Output voltage fluctuating or regulation poor. Output oscillating. TM-F2OP-C1XN-01 5-11