Download User`s manual for PSTN Touch Screen Wireless Alarm System

Transcript
User
User’’s manual for PSTN Touch Screen Wireless Alarm System
I. Foreword
Thank you for purchasing and using PSTN LCD touch screen wireless home alarm system. This is a Hi-tech household
security product. It will make your life safer and colorful.
Please read the below information carefully before using for a proper usage.
II. Brief introduction of the Product
Product components: This product is composed of alarm host, basic accessories and optional accessories.
Alarm Host
PSTN LCD
Alarm Host
Basic Accessories
Wireless Optional Accessories
remote, wireless intelligent door sensor(or wireless door
gas
alarm,
smoke
sensor) wireless wide-angle PIR sensor, , wireless indoor siren
wireless
with sound and flash
doorbell button
outdoor
alarm,
siren,
Table 1: Product components
III. Function Features
1.
Touch keypad; LCD displays Date, Day of the week, Time, and current Armed Status
2.
Supported Languages: Simplified Chinese\ Traditional Chinese\ English\ German\ French\ and more to meet different
3.
4.
market needs..
Landlline. Can preset up to 5 phone numbers and dial in sequence.
29 wireless zones (Each zone supports up to 4 sensors) and 2 dedicated zones for remotes (Supports up to 4
remotes or wireless keypads per zone). Supports 8 more wired zones(Optional).
Disconnection alarm, auto priority to occupy the telephone and monitoring function to hear what is happening.
6. Phone-line cut alarming
7. Intelligent logic analysis technology, corresponding zone number and sensor name can be displayed.
8. Record up to a 10 second greeting for the auto-dialer, Then play the greeting back.
9. Arm\ Disarm the system by 4 ways: Main Host(Keypad), Wireless Keypad, Keychain Remotes, or even remotely by
phones
10. Available in AC\DC with Low-voltage Indicators,Built-in Li-Ion backup battery, it will alert when low power or without external
5.
power supply.
11. Learning sensors to alarm host, very easy operation.
12. Non-volatile chip, information stored automatically when off power.
13. Check door\window status automatically (This is when the system is disarmed only, if a door is opened, it will sound
fast “bi bi bi”)
14. Bypass zone or not\ zone attribute\ entry delay or not..., all can be set from LCD menu
15. Support wireless “ding-dong” doorbell function (Optional)
16. Support CID uploading to CMS(Center monitoring Station)
17. Store up to 100 alarm records and 100 arm\disarm records
IV. Understanding of the Products
A. Understanding of the Alarm Host
布防
电源指示灯
08.08 星 期 6
12:26:28
状态 指示 灯
/
欠压指示灯
翻页键
编程键
眯 头
紧 急/ 修 改 键
布 防/数 字 键
撤防/全删/退出 键
确认键
正面图
警号接口
(可选)
录音键
放音键
ON
OFF
后备电
池开关
IN
TEL
OUT
电话线进口
喇 叭
电 源
8路有 线防区接 口(可 选)
背面图
Specifications:
1.
Working power: Input 100~230VAC, Output:500mA/12VDC
2.
Static current:<50mA (when not charging)
3.
Built-in Li-Ion backup battery: 3.7V 1200mAH(rechargeable),
4.
Battery: Can work around 16 hours in standby status, And need 12 hours to get Full charging
5.
Support up to 4 remote controller, and 116 wireless sensors
6.
Receiving and emitting frequency: 433MHz
7.
Working condition:
Temperature: -10ºC ~ 50ºC
Alarm current:<400mA
Humidity: <80%
电话线出口
8.
Product dimension:150×107×26(mm)
s and definitions
Zone type
types
�
�
Zone types: Perimeter zone, Motion zone, Emergency zone
Definitions:
Perimeter zone: Detecting the space like doors, windows, etc., generally use wireless door magnet sensors and wireless curtain
PIR sensors
Motion zone: Detecting the space like living room, aisles and bedrooms, etc., generally use wireless wide-angle PIR sensors.
Emergency zone: Detecting the space like Emergency area (such as emergency distress, medical rescue, gas leakage and
fire
alarm, etc., this zone keep 24-hour monitoring status automatically. Generally use panic button, wireless gas sensors and wireless
smoke sensors.
Modes of arming
�
“Away Arm” mode:Once any detectors in perimeter zones or motion zones get triggered, the host will alarm immediately and
meantime dial “#” automatically.
�
“Home Arm” mode:Once any detectors in perimeter zones get triggered, the host will alarm immediately and meantime dial
“#” automatically. It will not alarm after any detectors in the motion zone are triggered.
How to operate the alarm host
**Preparation
1. Connect the telephone cable: connect the telephone cable of telecommunication to “Tel in” port on the alarm host, then
use the telephone cable attached in the package to connect “Tel out” port and telephone set.
2. Connect power: connect the power adaptor to DC port of the alarm host first, then plug it to the AC socket.
3. Turn on the backup battery
�
How to program
Notes:
�
The host will exit programming mode if without any operation within 30 seconds
�
It will exit to the previous menu if press “ESC”
�
If enter codes by mistake for 3 times, the host panel will resume to the standby mode
�
you can press “▲▼” to adjust programming info. Or to find alarming info.
1、Menu preview
Main menu
Sub-Menu1
Set Time
Set time
Set Date
Set Date
Auto-dialer#’s
Call center
Entry Delay
Entry delay
Exit Delay
Exit Delay
Siren On/Off
Siren off
Siren on
Arm/Disarm
Beep
Arm/Disarm
Beep
Yes No
Sub-Menu2
Sub-Menu3
Sub-Menu4
Remark
Hour/minute/sec
ond
Year/Month/Day/
Week
Alarming phone
number, Group
2~5 for personal
Time delay for
enter
Personal Nbr#
Emergency
siren
Sub-Menu5
Perimeter siren
Motion siren
Time delay for
exit
Duration time
of
alarming
sound
No need to setup
for personal use
User Code
No need to setup
for personal use
Enter Usercode
Upload status?
Yes No
CutWire
Alarm?
Yes No
Upload Satus?
CutWire
Alarm?
Zone Attribute
Set Smart Zone
No need to setup
for personal use
Only applicable
for PSTN
Zone number
XX
XX Zone type
2 10
Zone number
Smart Sensor
ON
Yes
No
Program
Sensor
Zone number
Wireless Code
Wireless Code
Group no.
Alarm Type
XX
Bypass Zone?
Yes No
Smart
ON
Zone Indicator
Yes
No
Sensor
Yes No
Attribute Set?
Yes No
Activate
Sensor
Delete Sensor
Alarm History
Needed
when
adding wireless
sensors
Detect
and
indicate
open/close states
of doors/windows
For Adding or
deleting wireless
sensor
Usually no need
for users
For checking
alarming history
records.
For checking
working records
Status History
The detailed settings are as below:
For any program, you should start with【SET + Enter code + input the 6-digit code (default: 888888)+ENT】
【Set time】:
【ENT + press “
” to delete the old record + input current time+ENT】→ “X X X X X X”: 6 digits, means “hour, minute,
second”, each takes 2 digits space, e.g. you may press 142120, now the host time will be 14:21:20.
【Set date】:
【ENT + press “
” to delete the old record + input current date and week +ENT】→ “X X X X X X”: 7 digits, means “year,
month, day and week”, e.g.:0701174, means Jan 17th, 2007, Thursday. (“0” means Sunday.)
【Auto Dialer#’s】:
�
Totally 5 telephone/mobile numbers
�
The first group is fixed for management center,other 4 groups are fixed for personal numbers
�
Press ENT to confirm each phone(telephone/mobile) number
---【1: Call Center】:
【ENT + 1: Call Center + press “
” to delete the old record + input the number you want to preset+ENT】
---【2: Personal Nbr】:
【Press ENT continously till you see “2: Personal Nbr” + press “
” to delete the old record + input the number you want to
preset+ENT】→ personal number is fixed from Group No. 2 to 5, press ENT to set next personal number.
【Entry delay】:
【ENT + Entry Delay+ press “
” to delete old record + X X + ENT】→ “X X”: 2 digits, you can set 00~59 seconds.( default:
“00”)
Very important notes: If you hope the “Entry delay” to be function, you need to set from 2 places, one is from above “Entry
delay” menu, the second is to set from “Zone attribute” (Details: Set—Pw- Zone attribute—Zone Number—Zone
Attribute Set
Type—Alarm type—Silent Alarm—Attribute
Set) , you need to choose “YES” in the step of “Attribute Set”
【Exit delay】:
【ENT + press “
” to delete the old record + X X + ENT】 → “X X”: 2 digits,you can set 00~59 seconds.(default is: “15”)
【Siren On/Off】:
【ENT + Siren On/Off, press “▲▼” to choose ON or OFF. 】
If choose ON, the system will have alarm sound when alarm trigered. You need to setup the alarming delay time(seconds) in
the next sub-menus. Please do as following:
ENT +press “
” to delete old record + input new time X X + ENT. You can set 00~60 minutes, the default is “03”
If choose OFF, just press ENT to confirm is ok. Then the system will not alarm when sensors triggered.
【Arm/Disarm Beep】:
ENT + Arm/Disarm Beep, press “▲▼” to choose YES or NO. The default set before shipment is “YES”.
【User code】:
Here need to setup only based on linking network. Operations: ENT + press “
” button to delete old record + X X X X +
ENT】 → “X X X X”: 4 digits, you can set 0000~9999. Default set before shipping is at ransom.
【Upload status】:
This is for uploading Arm/Disarm/Alarm information to the Managing Centre. Operations:【ENT + “▲▼” + ENT】 → “▲▼”
choose “yes” or “no” for upload or not upload. The defaulted is “No”.
【CutWire Alarm】:
This is for PSTN (landline) only. ENT + CutWire Alarm, press “▲▼” to choose YES or NO. If choose “Yes”,it will alarm when
telephone line is not connected. Default set before shipping is “Yes”.
【Zone Attribute】:
Here is for setting【Zone number】,【Zone type】, 【Alarm Type】【Bypass Zone】 &【Attribute Set】(Entry Delay).
Zone number
-----【Z
number】:
Here has 39 zonesfor your settings. 2 dedicated zones for remotes(Supports up to 4 remotes or wireless keypads per
zone).29 wireless zones(Each zone supports up to 4 sensors) and 8 optional wired zones. Each zone needs to setup “Zone
Type”, “Alarm Type” ,“Bypass Zone” & “Entry Delay”.
Table 3: “Zones Number
Number”” setting
Zone
Sensor Type
Number
Zone
Applicable sensor names
Type
——
00、01
02 ~ 10
Notes
Wireless remote & Wireless Keypad
Emergency zone
Wireless sensors
11 ~ 20
Perimeter zone
21 ~ 30
Motion zone
Wireless Smoke Alarm,
Each zone
support up to 4
sensors
Wireless Gas Alarm& Panic button etc.
Wireless Door/Window Sensor &
Wireless Curtain PIR etc.
Wireless Wide-Angle PIR Motion Sensor etc.
Pls check below
31,32,33 are Perimeter zone
31 ~ 38
— —
Wired sensor
Table 4:
34,35 are Motion zone
Wireless/wired
36,37,38 are Emergency zone
sensor code
Zone Type
【Zone
ype】:
You can see “2”, “1”, “0”.( “2” mean motion zone, “1” means perimeter zone, “0” means emergency zone)
Press “▲▼” to choose the one you desire to setup, then press ENT to confirm your settings.
Alarm Type
【Alarm
ype】:
【ENT + Alarm Type+ press “
” button to delete old record + X X + ENT】→ “X X”: 2 digits. Alarm type code. 2 digits.( See
below table. )
Code
Sensor
Name
Code
Sensor
Name
00
01
02
03
04
Button0
Button1
Gas
Smoke
08
09
10
11
12
13
14
15
20
IR
Perimeter
Perimeter
Motion
Sensor
Sensor
Sensor
Sensor
(doorbell)
Door
05
Window
06
07
Glass
Motion
Table 5: Default set before shipment
Wireless sensors
Wireless
Wireless door
remote
sensor
Wireless
wide-angle
PIR sensor
Wireless gas
Wireless
sensor
smoke sensor
Zone Number
00
11
21
02
03
Bypass Zone
【Bypass
Zone】:
Actually this menu means “Silent Alarm?” , This setting is for make zones enable or disable. Here has “Yes” & “No” for your
alternatives. “Yes” means make this zone’s sensors silent, “No” means keep this zone’s sensors working. Press “▲▼” to
choose “Yes” or “No”, then press ENT to confirm your settings.
【Smart Zone Set】:
Zone Numner
-----【Zone
Numner】:
【ENT + Zone Number+ press “
” button to delete old record + X X + ENT】→ “X X”, zone number, 2 digits.
Smart Sensor ON
-----【Smart
ON】:
This is for open and close the intelligent door/window sensor function.
【ENT + Smart Sensor ON, press “▲▼” to choose YES or NO. 】”Yes” for open, “NO” for closed.
Smart SensorON
-----【Smart
SensorON】:
This is for open and close the status of the zone( no need to set for wired zones).
【ENT + Smart SensorON, press “▲▼” to choose YES or NO. 】”Yes” for open, “NO” for closed.
Zone Indicator
-----【Zone
Indicator】:
This is for setting if the zone needs sound indication while disarmed status.
【ENT + Smart SensorON, press “▲▼” to choose YES or NO. 】”Yes” for open, “NO” for closed..
Program Sensor
【P
Sensor】
This setting is for adding or deleting Sensors in the above mentioned Zones(Includes Zone 00, 01).
【ENT + Zone Number+ press “
【ENT + Group Number+ press “
” button to delete old record + X X + ENT】→ “X X”, zone number, 2 digits. Refer to Table 3.
” button to delete old record + X X + ENT】→ “X X”,group number , 2 digits.
This Group Number is for Sensors’ numbers, each zone can be connected up to 4 sensors, the Group Number is from 00 to 03.
“00” means Sensor 1, “01” means Sensor 2, “02” means Sensor 3, “03” means Sensor
【ENT + press “▲▼” to choose “ActivateSensor” or “Delete Sensor” 】
If choose Activate Sensor
This means adding Sensors to this host. Operations:
Get a sensor learning to the host, the word “learning” will show on the LCD Screen, if have been learned, the word “success”
will show on the LCD Screen.
Note: If a word “update?
update?”” shows on the screen, which means this sensor has been added before, you may choose
“Yes
Yes”” or “No
No”” to decide going on programming or not for this sensor.
If choose Delete Sensor,
This means deleting the added sensors from the host. Operations:
Get into the Program Sensor menu, choose Zone Number and Group Number you desire to delete, press “▲▼” to choose
Delete Sensor, press ENT, the host will give a long beep sound. Then the words “Deleting Sensors Success” will show on
the LCD Screen, which means you have deleted the sensors successfully.
【Wireless Code】
【ENT + press “
” button to delete old record + X XXX + ENT】→ “XXXXX”, range of code , 5 digits. Default setting before
shipment is at random.
【Alarm History】
【ENT + Alarm History, press “▲▼” to review.】
【Status History】
【ENT + Status History, press “▲▼” to review.】
Note
Note:Press “ESC” to exit from the programming status after finish settings
How to Revise Master code
This setting is for changing the “Enter Code” of the host. The defaulted “Enter Code” is “888888”. If you desire to change, you may do as
below:
【ENT + 999999 + ENT + Enter New Code + Input 6-digit new code + ENT + Re-Enter Code】The host panel will be back to the standby
mode after successful programming.
Note: If input the codes 3 times by mistake, the host will be back to the standby mode automatically
automatically..
How to operate the Alarm Host?
1.Record:Keep pressing the “record button” on the back of the alarm host and speak close to the speaker of host. Tthen release, the
voice recorded.
2. Play:Keep pressing the “play button” on the back of the alarm host and you will hear the previous record.
3. Arm:BY wireless remote:press the corresponding arm button and the host will beep once to successfully complete the operation
By Host panel(Keypad): 【0 + master code + ENT + “▲▼” + ENT】 → “▲▼”to choose “armed home” or “armed away”
4. Disarm: By wireless remote: press the corresponding disarm button and the host will beep twice to successfully complete the
operation
By Host panel(Keypad): 【ESC + master code + ENT 】 →the host will beep twice to successfully complete the operation
5. Emergency: By wireless remote: Press Emergency key and the host will alarm immediately;
By host panel(Keypad): press
,and the host will alarm immediately.
6. Telephone alarm: After receiving the call, you will hear the recorded voice message immediately, it can be played for 30 seconds
repeatedly, then follow the below instruction:
6.1. Input “8” to enter into the listening status for 20 seconds automatically, you can hear the alarming event
sounds from phone. Each extra press of “8” can prolong 20 second listening in.
6.2. Input”#” to play the recorded voice message for one time automatically
6.3. Input “*”, the host will end the call and stop dialing any auto dialer#.
6.4. Directly hang off the telephone, the host will end the call and automatically dial the next auto dialer#.
7.Arm remotely by phone: 30 seconds after successfully dial the telephone number of host,
enter the password of host after the
beep---enter 1 after beep—the host will automatically hang up after beep to successfully complete the
operation.
Notes: You can set “Armed Away” remotely by phone, but keep notes that you can’t set “Armed Home”
by this way.
8. Disarm remotely by phone: 30 seconds after successfully dial the telephone number of host,
enter the password of host after the
beep---enter 0 after beep—the host will automatically hang up after beep to successfully complete the
operation.
9. Long-distance monitoring:Dial alarm host, line would be connected around 30 seconds,you will hear a "Di", then, it will
enter "20 seconds monitoring", so, you can listen the spot, and if you hope to listen again, just press "8"
10. Alarm records checking: just press“▲▼”button to check, store up to 100pcs record
11. Working records checking: just press“▲▼”button to check, store up to 100pcs record
12. Disarm: by remote, just press the disarm button, the host panel will sound "di di" 2 times means successfully.
13. Monitoring of door/window status: When the smart zone is ON, the arm operation is normal if all the doors or windows
are closed. But if any door or window is open, the host will sounds “Di Di Di” and at the same time it has below
displays alternately:
“XX”: zone number;
“YYYYY”: sensor name;
Not Ready
Arm Anyway
XX YYYYY
Y N
Arm Anyway
Y N
Note: 1. This function is available only with wireless intelligent door sensor programmed.
2. If arm by long distance phone call, the operation is same as original.
3. If arm by remote controller or wireless keypad, it will arm successfully after two succsessive arm operation.
14.Wireless din-dong doorbell function: when you press the doorbell button, the host panel will sound "ding-dong" 3 times,
please take note, this function is additional, only add doorbell, then, this function can be available.
Operation notice
� Alarm processing mode: immediately after the system alarms, it starts to dial in sequence from the 1st group number
to the 5th group number(skip empty numbers) automatically. It dials circularly for three times, the answered number
will not dialrepeatedly.
�
Exit delay alert: the alarm host sounds “Di” every 1 second (door/window is closed) within preset exit delay time.
�
Alarm delay alert: the alarm host sounds “Di” every 1 second within preset alarm delay time.
�
Alarm priority: 1. If the alarm host’s own telephone line is accupied when it is alarming, it will cut it and make it
unoccupied, at the same time dial out to report alarm event.
2. The alarm host’s “Ding Dong” sound will switch to alarm sound and dial to report if it receives
alarms signal when sounds “Ding Dong” .
�
External power supply cut alert: the alarm host sounds “Di” every 8 seconds.
�
Telephone cable disconnection alarm: the alarm host goes off when telephone cable is disconnected, after 5 seconds
alarm, it will sounds “Di Di Di” every 8 seconds.
Lower voltage alert: the alarm host sounds”Di Di Di” every 8 seconds when power gets very low.
How to connect optional wired sensors (2.2K balance resistor is necessary)
1
Red
+
Black
-
White
Zone 31
Yellow
Zone 32
Blue
Zone 33
curtain PIR sensor
Green
Zone 34
wide-angle PIR sensor
wide-angle PIR sensor
panic button
gas sensor
smoke sensor
Purple
Zone 35
Brown
Zone 36
Grey
Zone 37
Orange
Zone 38
sensor +12V power output
GND
door sensor
curtain PIR sensor
10
B. Understanding of Basic Accessories (Wireless)
Wireless Remote
Away
Features:
� To control the alarm host to arm and disarm.
� With the emergency key for urgent help.
Disarm
Specifications:
� Operating power: 27A 12V alkaline battery
Home
Emergency
� Emitting distance: ≥100m (in open area)
� Service life: ≤2 years
Installation and Usage:
� For users to take along.
� Generally, press the “Away” key to arm before leaving home; and press the “Disarm” key to disarm; “Home” is
setting “Armed home”, please take notes that “Arm Home” is only effective for sensors in Perimeter Zone (door
sensor\curtain PIR sensor) and sensors in Emergency Zone (Like Gas sensor\Smoke sensor\Glass
sensor\Emergency button), it is not effective all sensors in Motion zone(Like wide-angle PIR).
� Please replace the batteries after one year usage and when you feel shorter control distance.
How to program
Please refer to the descriptions of 【Program Sensor】or Table 6.
Note:
� You can only add 1 remote each time, totally 8 available to be added.
�
Each serial number is available to study 1 remote, the latter configured remote will be workable and the former
one becomes not workable automatically.
Wireless Intelligent Door Sensor
Features:
� Generally set as Perimeter zone.
� If any door or window is opened, it will transmit the alarm signals to the alarm host.
Specifications:
� Operating power: 23A 12V alkaline battery
� Frequency: 433MHZ
� Emitting distance: ≥100m (in open area)
� Service life: ≤1 year
� Alarm Distance: <4cm
Installation and Usage
� Fix the part of magnet onto the door frame in a position of 1.6m above the ground to prevent any children from
bumping onto it
� Fix the part of emitting onto the door frame, make sure to keep the part of magnet and part of emitting in parallel,
the space between the two parts shall be less than 10mm
� Upon the working light flashes frequently in red, please replace the batteries
How to program
Please refer to the descriptions of 【Program Sensor】or Table 6.
Note:
� You can only add 1 wireless door magnet each time, totally 4 available to be added.
� Each serial number is available to study 1 wireless door magnet, the latter configured wireless door magnet
will be workable and the former one becomes not workable automatically.
Wireless Door Sensor (Sames as Wireless Intelligent Door Sensor)
4. Wireless wide-angle PIR Sensor
021
Working Light
D0
O n / O ff
D3
Low-Votage
Light
Power Switch
Down/Off
Up/On
Lens
Learning Emitting Switch
Jump Line
Fix the PIR by pushing
it downwards
Install the bracket
Wa ll
Wa ll
K e e p th e sw itch "o n "
Wa ll
Features:
� Mainly monitor and control indoor space, generally set as Motion zone.
�
When human body enters into etecting area, the sensor will transmit alarm signals to the alarm host.
Specifications:
� Operating power: 9V alkaline battery
� Emitting distance: ≥100m (in open area)
� Service life: ≤1 year
� Detecting distance: 110° 10×10m
Installation and Usage
� Fix the bracket on suitable wall surface or in wall corner at a distance of 2~2.4m above the ground;
� Open the sensor shell to connect the batteries well and adjust jumper line (short circuit “5S”: The sensor will detect
once every 5 seconds; short circuit “5MIN”: The sensor will detect once every 5 minutes;
Suggestion: short circuit “5S
5S”” for testing and “5MIN
5MIN”” for normal use;
� Fix the sensor onto the bracket;
� Adjust the sensor to a proper angle and then slide the power switch on the side to “ON”, and it will enter into the
normal working state after 30 seconds;
� Upon the working light flashes frequently in green, please replace the batteries.
How to program
Please refer to the descriptions of 【Program Sensor】or Table 6.
Note:
�
You can only add 1 wireless wide-angle PIR sensor each time, totally 4 available to be added.
�
Each serial number is available to study 1 wireless wide-angle PIR sensor, the latter configured wireless
wide-angle PIR sensor will be workable and the former one becomes not workable automatically.
Wireless Indoor Siren
Features:
� Work with alarm host, wireless receiving alarm signals, spot alarming with
sound and flash
� With power plug, usually for indoor use.
Specifications:
� Operating Power: 100~240VAC
� Receiving Distance:≥100 M(In open area)
Installation and Usage:
� Plug the wireless siren into suitable indoor power socket
� Suggestion: Generally around 1.8M from the ground
How to program
Please refer to the descriptions of 【Program Sensor】or Table 6.
Notes:
�
You can only add 1 wireless siren each time.
�
When configure the wireless siren, you can only operation on the keypad of the alarm host.
�
One siren can be studied to at most 10 wireless alarm hosts, multi wireless sirens are available to be added for
each alarm host.
C. Understanding of Optional Accessories (Wireless)
Wireless Gas Alarm
Features:
�
Mainly monitor and control indoor gas leak, generally set as
Emergency Zone.
�
Usually installed in kitchen
Specifications::
�
Operating power: 110~240VAC,50~60HZ
�
Emitting distance::≥100m (in open area)
�
Inductive gas:
Natural gas: 0.1%-0.5%
Liquefied petroleum gas (LPG): 0.1%-0.3%
Working Light
Test Button
Power Light
Air Hole
Installation and Usage:
�
Fix the gas alarm onto proper wall surface inside the kitchen.
�
Connect the alarm to the power and it will be ready to detect after two minute
How to program
Please refer to the descriptions of 【Program Sensor】or Table 6.
Note:
�
You can only add 1 wireless gas alarm each time, totally 4 available to be added.
�
Each serial number is available to study 1 wireless gas alarm, the latter configured wireless gas alarm will be
workable and the former one becomes not workable automatically.
Wireless Smoke Alarm
Features:
� Mainly monitor and control indoor fire risks, generally set as Emergency Zone.
� Replace the batteries for every 1 or 2 year.
� Usually installed on the ceilings of living room and aisles.
Specifications:
Wor king Ligh t
Air Hole
� Operating power: 9V alkaline battery
Tes t But ton
� Emitting distance: ≥100m (in open area)
� Service life: ≤1 year
� Monitoring range: 20m
How to program
Please refer to the descriptions of 【Program Sensor】or Table 6.
Note:
�
You can only add 1 wireless smoke alarm each time, totally 4 available to be added.
�
Each serial number is available to study 1 wireless smoke alarm, the latter configured wireless smoke
sensor will be workable and the former one becomes not workable automatically.
Wireless outdoor siren
Features:
�
Nice, exquisite and waterproof
�
Mico-computer controlling, steady performance and high-class quality
�
Study to at most 10 pcs of wireless alarm host
�
With inbuilt charging circuit and back up accumulators, automatic AC power and DC power transformation
�
Low standby power consumption, self-inspection of lower battery voltage, automatic charging
�
Wall hanging installtion
Specifications:
�
Operating power:110~240VAC, 50Hz
�
Static power consumption:≤40 mA
�
Working power consumption:≤450 mA
�
The maximum alarm sound with flash:
3 Minutes
�
Receiving distance:≥100M(In open area)
�
Alarming volume:≥105db
Installation and usage
� Press down the green power switch on the back after connecting to the AC power
� Study the siren to the alarm host according to the instruction below
� Unplug from the AC power, fix it in the proper outdoor place with handing hook, and then plug to the AC power
� The max time for alarming sound with flash is 3 minutes, it will stop automatically after the alarm host is disarmed
� When the back-up battery has a lower voltage than 5VDC, the charging indicator turns on, the back-up
accumulators will be charged automatically, the approximate charging time is 20 hours,
when the charging
indicator off, it means it has finished charging
How to program
Activate
� (Siren) connect the siren to power by plugging in to the socket------ press red studying switch on the back, siren
lights on
�
(Alarm host) Press
on the alarm host to let the alarm host goes off------ Let it stop alarming (
-----Input
programming password---ENT)---you will hear “DIDI” from the alarm host after 5 seconds
� One siren can be studied to at most 10 wireless alarm hosts, multi wireless sirens are available to be added for
each alarm host.
Deactivate
� Keep pressing the red button for 10 seconds and a successful deactivation will be followed by a flash of the
alarming light
all the alarm hosts will become invalid to this siren after this operation
Note
Note:all
Wireless doorbell button
Features
Installed in the entrance, the alarm host will sounds “Ding Dong” if someone press it.
Specifications:
� Operating power:3.7V Li-Ion battery.
� Emitting frequency: 433Mhz
� Emitting distance: ≥100M(In open area)
� Service life: ≤1 year
Installation and usage
1. Fix the base on the wall in a position of 1.6m above the ground.
2. Then fasten the main part with the base.
3. Change batteries when indicator flashes frequently in green.
How to program
Please refer to the descriptions of 【Program Sensor】 (The doorbell button has its fixed zone number---“20”)
Note:
� You can only add 1 wireless doorbell button each time, totally 4 available to be added.
� Each serial number is available to study 1 wireless doorbell button
button,, the latter configured wireless doorbell
button will be workable and the former one becomes not workable automatically.
Table 6 : Preview of how to activate and deactivate “Basic accessories (Wireless)
(Wireless)”” and “Optional accessories (Wireless)
(Wireless)””
Type
Zone
No.
Max.
no. to
be
progr
amme
d
How to activate
How to deactivate
B
as
ic
ac
ce
ss
ori
es
(
Wi
rel
es
s)
Remote
00、01
8
1) 【SET +Programming code + “▲▼”
“Program sensor” + ENT + “
” + Y Y + ENT
+“
” + X + ENT + “▲▼””Activate sensor” +
ENT 】(The screen would say learning)
2) Press any key on the remote twice
successively,
the
host
LCD
will
display ”Success”;
Door
Sensor
11~20
4
1.Same as above
2.Trigger the door sensor twice successively
Same as above
4
1.Same as above
2.Trigger the PIR sensor by pressing
”Learning Emitting Switch” on the panel twice
successively
Same as above
N/A
——
1.After connecting to the power, press the
“learning switch on the side of the siren
2. Press“ ” key on the alarm host, disarm by
keypad on the alarm host after about 5 seconds.
3. Lights of the siren flashes 5 times and
then
off indicates successful activating
After connecting to the power, keep pressing the
“Learning” switch on the side of the siren for 5
seconds and release, lights on the siren flashes
1 time and then off indicate successful
deavtivating
Gas alarm
02~10
4
1. Same as above
2. Trigger gas alarm by releasing gas,
the host LCD will display “Success”
Same as above
Smoke
Sensor
02~10
4
1.Same as above
2.Trigger smoke alarm by releasing
smoke, the host LCD will display “Success”
Same as above
Outdoor
Siren
N/A
——
Same as wireless indoor siren
Same as wireless indoor siren
Wide-Angle
PIR Sensor
Indoor siren
21~30
1) 【SET +Programming code + “▲▼”
“Program sensor” + ENT + “
” + Y Y + ENT +
“
” + X + ENT + “▲▼”Delete sensor” +
ENT 】
2) The alarm host will beep once and press
ESC to exit.
V. Common Problems and Solutions
Symptoms of Faults
The alarm host can’t fully record
Repeatedly receiving the alarm
telephone
Possible Cause
Solution
Did not keep pressing the record all
Keep pressing the record all the time while
the time while recording
recording
Fail to operate according to the operation
instruction of the telephone alarm
Follow the below instructions after answering the alarm
phone calls and hearing the recorded message:
(See Point 6 of “How to operate the Alarm Host?”)
Can’t receive alarm sms or can’t
receive sms reply after made arm
or disarm operation by sms
The host does not alarm after the
detector is triggered in arm state
1. SIM card is not insert properly
2. GSM signal is not good enough
The PIR sensor doesn’t work
1. Not properly connected to the power
2. Port of the detector is in the
power-down mode.
1. Caused by the functions of arm mode
(Armed Away and Armed Home);
2. Have already setup time for Entry
Delay or Exit Delay
1. Insert SIM card properly
2. Adjust alarm host’s installation position till the signal
status shows “OK”
1.“Armed Away” mode: alarm goes off when any sensor
is triggered;
2. “Armed Home” mode: alarm goes off when any sensor
in Perimeter zone is triggered and it won’t alarm when
any sensor in Motion zone is triggered
3. Program to adjust the time for Entry Delay or Exit
Delay
1. Open the sensor shells to install the batteries well
and slide the power switch to “On”;
2. “5S”: detect once every 5 seconds;
“5MIN”: detect once every 5 minutes;
The detecting distance of PIR
sensor gets shorter
The ambient temperature
detecting area is too high.
in
the
The host does not alarm after the
new added wireless detector is
triggered.
The PIR sensor flashes frequently
in green.
The door sensor
The distance of the remote
controller gets shorter.
Failed to follow the operation instruction
of “Adding and deleting sensors” to add
the new wireless sensor
Batteries are running out.
Batteries are running out.
Batteries are running out.
When the ambient temperature in the detecting area
exceeds the human body temperature, the detecting
distance will get shorter, it’s normal.
Follow the operation instruction of “How to program” to
activate the new wireless sensor
Replace with new batteries of the same specification.
Replace with new batteries of the same specification.
Replace with new batteries of the same specification.
VI. Daily Maintenance and Care
This alarm is the hi-tech product with the outstanding design and sophisticated technique, and shall be used carefully. To make the
alarm to operate for a long term stably and to prolong the service life, it is recommended that:
�
Try to put the alarm host in the dry and well-ventilated places.
�
Do not put the host and any wireless detectors in too cold, too hot or dusty places to prevent it from curtailing the service lives of
electric parts and preventing the plastic shell from distorting and accelerating to age.
�
Do not put the host and any wireless detectors in low and too exposed places to prevent the children from touching them or the
thieves from finding them.
�
Regular testing is necessary for finding and resolving problems in time.
�
Regularly check the batteries in all wireless sensors and replace the running out batteries to ensure the normal operation of them.
�
You’d better keep the power of the alarm host and all wireless accessories off while a long-time vacancy of the system.