Download Specifications
Transcript
CAMPUS CHILLED WATER PIPING – UNIVERSITY OF NORTH GEORGIA Spencer Bristol Engineering, Inc. 15. 16. 3.02 finished, whether in concrete, steel grating, metal panels, roofs, or other building features. Provide nonshrink grout or foam sealant at all sleeves or holes after the installation of conduit and at all unused sleeves. Install fire- and smoke-rated seals at all conduit penetrations or sleeves of fire-rated floors, ceilings, walls, or partitions. Coat all field-cut threads in galvanized conduit with aluminum paint, zinc treatment cold galvanizing compound, or other approved treatment material. APPLICATIONS FOR CONDUIT PERMITTED: A. Interior Installations, Concealed in Walls or Above Ceilings, or Exposed: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Unless excluded below, not permitted in accordance with the National Electrical Code, or otherwise indicated, all conduit shall be Electrical Metallic Tubing. Conduit shall be run parallel or at right angles to existing walls, ceilings, and structural members. Support branch circuit conduits at intervals not exceeding 10 ft. and within three feet of each outlet, junction box, cabinet or fitting. Attach individual branch circuit conduits to structural steel members with spring steel type or beam conduit clamps and to non-metallic structural members with one hole conduit straps. For exposed conduits and where conduits must be suspended below structure, single conduit runs shall be supported from structure by hangar rod and conduit clamp assembly. Multiple conduits shall be supported by trapeze type support suspended from structure. Do not attach conduits to ceiling suspension system channels or suspension wires. Attach feeder conduits larger than 1" trade diameter to or from structure on intervals not exceeding 12 ft. with conduit beam clamps, one hole conduit straps or trapeze type support in accordance with support systems described for branch circuit conduits. Exposed conduits shall be painted as specified under the PAINTING section of the specifications, or as otherwise indicated in the Architectural documents. Do not install conduits through structural members. Install conduit sleeves in slabs where conduits 2.0" and larger pass through. Sleeves shall extend 1" minimum above finished slab. Install all conduits or sleeves penetrating rated fire walls or fire floors to maintain fire rating of wall or floor. Conduits attached to building construction on opposite sides of a building expansion joint shall be provided with an expansion and deflection coupling. In lieu of an expansion coupling, conduits 2-1/2" and smaller may be provided with junction boxes on both sides of the expansion joint connected by 15" of slack flexible conduit with bonding jumper. No conduit installation requiring cutting of cross-webs of concrete masonry units is permitted. Conduit shall be threaded through cells or concrete masonry units lowered around conduit. Neither horizontal joint reinforcement nor bond beam reinforcement shall be cut for conduit installation. Conduit types shall not be mixed indiscriminately with other types in the same run, unless specified herein or required by the NEC. Conduits which penetrate the building exterior walls or roof shall be RGS or IMC. CONDUITS AND BOXES 16130-7