Download SkyAir Non-Inverter R-410A Cooling Only Type

Transcript
PCSVN1420A
Warning
Ask a quali ed installer or contractor to install this product. Do not try to install the product by yourself.
Improper installation can result in water or refrigerant leakage, electrical shock re or explosion.
Use only those parts and accessories supplied or speci ed by Daikin. Ask a quali ed installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
re or explosion.
sho
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Đại lyù phaân phoái:
TRUNG TÂM
DICH VU KHÁCH HÀNG
Miễn phí cöôùc cuoäc goïi
notice.
c All rights reserved 07/14
SS
New wide lineup of SkyAir series.
Product Lineup
Series
Btu/h
kW
09
13
18
21
1
26
30
36
42
2
48
2,3
9,200
13,000
18,000/17,700*
21,000
26,000
30,000
36,000/35,000*
2.7
3.8
5.3/5.2*1
6.2
7.6
8.8
10.6/10.4*2
42,600/42,000*
12.5/12.3*2,3
48,000
14.1
FCNQ13MV1
FCNQ18MV1
FCNQ21MV1
FCNQ36MV1
FCNQ42MV1
FCNQ48MV1
RNQ13MV1
RNQ18MV1
RNQ21MV1
RNQ42MY1
RNQ48MY1
FHNQ13MV1
FHNQ18MV1
FHNQ21MV1
FHNQ42MV1
FHNQ48MV1
RNQ13MV1
RNQ18MV1
RNQ21MV1
RNQ42MY1
RNQ48MY1
FDBNQ09MV1
FDBNQ13MV1
FDBNQ18MV1
FDBNQ21MV1
RNQ09MV1
RNQ13MV1
RNQ18MV1
RNQ21MV1
CEILING MOUNTED
CASSETTE TYPE
Round Flow
Indoor unit
Outdoor unit
FCNQ26MV1
RNQ26MV1
RNQ26MY1
FCNQ30MV1
RNQ30MV1
RNQ30MY1
RNQ36MV1
RNQ36MY1
CEILING SUSPENDED TYPE
Pair
Indoor unit
Outdoor unit
DUCT
CONNECTION
FHNQ26MV1
RNQ26MV1
RNQ26MY1
FHNQ30MV1
RNQ30MV1
RNQ30MY1
FHNQ36MV1
RNQ36MV1
RNQ36MY1
LOW STATIC
PRESSURE
TYPE
Indoor unit
Outdoor unit
FDBNQ26MV1
RNQ26MV1
RNQ26MY1
MIDDLE STATIC
PRESSURE
TYPE
FDMNQ26MV1
Indoor unit
Outdoor unit
FDMNQ42MV1
FDMNQ48MV1
RNQ26MV1
RNQ26MY1
RNQ30MV1
FDMNQ30MV1
RNQ30MY1
RNQ36MV1
FDMNQ36MV1
RNQ36MY1
RNQ42MY1
RNQ48MY1
RNQ26MV1
RNQ26MY1
RNQ30MV1
RNQ30MY1
RNQ36MV1
RNQ36MY1
RNQ42MY1
RNQ48MY1
OUTDOOR UNIT
Outdoor unit
RNQ09MV1
RNQ13MV1
RNQ18MV1
RNQ21MV1
Note : *1Applicable to FDBNQ series. *2Applicable to FHNQ series. *3Applicable to FDMNQ series.
1
2
CEILING MOUNTED CASSETTE TYPE
Round Flow
Avoids uneven temperature and discomfort caused by drafts.
Cassette air conditioner with 360°
uniform airflow sets the standard
Comfort enhanced by Round Flow!
FCNQ13/18/21/26/30/36/42/48MV1
360° airflow
Air movement is gentle with Round Flow
With uniform temperature
distribution
Enhanced Comfort
360° airflow can
maintain comfort
even if air
discharge speed is
lower.
Airflow
distribution
Creates uniform
comfort throughout
the space
If you raise the set
temperature by 1 to
1.5°C,and velocity is
decreased by 25%,
you still obtain the same
feeling temperature and
comfort.
Sound level
43/32dB(A)
High
Low
FCNQ36M
Option
Accessory required for indoor unit.
Greater comfort
Improved energy saving
(220V)
Wired LCD remote controller
Adapts easily to the installation space.
BRC1C61
Note: Remote controller cable not
included. Cables must be
procured locally.
Because air flows out from corner outlets, comfort spreads more widely.
Typical flow patterns
Navigation Remote Controller
(Wired Remote Controller)
There are a total of 23 flow patterns.
All-round flow
3-way flow
(E.g., installed in
middle of ceiling)
(E.g., installed
near a wall)
L-shaped
2-way flow
Opposite
2-way flow
BRC1E62
Note: Remote controller cable not
included. Cables must be
procured locally.
A signal receiver must be added to the indoor unit.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to
close each unused outlet.
Operation sound increases when using 2-way or 3-way flow.
BRC7F633F
Grime prevention and bactericidal coating: Make cleaning easier.
Signal receiver unit
(Installed type)
External panels are treated with a coating that
Treated
Untreated
repels dirt.
surface
surface
Wireless remote controller and signal
receiver unit are sold as a set.
Features
*1Applicable when wired remote controller is used
*2Applicable when BRC1E62 is used
*3Applicable when BRC1C61 is used
3
*4Applicable to RNQ30-48M outdoor units
*5Applicable to RNQ13-26M outdoor units
*6For the outdoor units
Fresh air intake kit
• • • • • • • • • • • • •
Others
Anti corrosion treated
heat exchangers
Ultra long-life filter
High-efficiency filter
Options
DIII-NET communication
standard
Interlock control
Central remote control
External command
control
*5
Group control by 1 remote
controller
*4
Control by 2 remote
controllers
•
Auto-restart
•
Control features
Ceiling soiling prevention
*3
Filter sign
*2
Long-life filter
On/Off timer
*2
Pre charged for
up to 10 m
Off timer (programmed)
*2
Pre charged for
up to 15 m
Weekly schedule timer
*2
Drain pump mechanism
Setpoint range set
*1
Work & Servicing
Cleanliness
Anti-bacterial air filter
Setpoint auto reset
• • • • •
Two selectable
temperature-sensors
High ceiling application
Programme "Dry"
Switchable fan speed
(2 step)
Swing pattern selection
Auto swing
Remote controller
(E.g., installed in
a long room)
4-way flow also possible.
Wireless LCD remote controller
Comfort
(E.g., installed in
a corner)
*6
To prevent dirt sticking to the
external panels, they have
been coated with a surface
treatment.
Resists
soiling
Grimy
surface
• Condition after exposure
to the smoke of 600
cigarettes in 1 m3
enclosed space.
Non-flocking flaps
Filter has anti-mould and bactericidal treatment
Condensation does not easily form on and dirt does not
cling to non-flocking flaps.
It is easy to clean.
Prevents mould and microorganisms growing out of the dust and
moisture that adheres to the filters.
4
CEILING MOUNTED CASSETTE TYPE
Fine square panels
Compact body and quiet operation
mm
95
0m
Indoor unit
High
Low
13/18M
21/26M
30/36M
42M
48M
31
35
43
44
44
28
28
32
34
36
Same for
all models
m
Optimal comfort and convenience
assured by 2 air discharge modes
Note: Air direction is set to the standard position when the unit is shipped from the factory.
The position can be changed from the remote controller.
Air direction
Standard setting
Setting to prevent soiling of ceiling*
Desired
situation
Standard position to
prevent draft.
Recommended for shops with
light coloured ceilings that
must be kept spotless.
Note : Anechoic chamber
conversion value, measured
according to JIS parameters
and criteria. During
operation these values are
somewhat higher owing to
ambient conditions.
Quick and easy to install
5-levels
air direction
setting
Auto-swing between
15° and 60°
Auto-swing between
25° and 60°
Settable to 5 different
levels between 25° and 60°
Settable to 5 different
levels between 15° and 60°
The air direction is set automatically to the
memorised position of the previous air direction.
Auto air
direction control
*Closing of the corner discharge outlets is recommended.
Suitable for high ceilings
Even in spaces with high ceilings, a comfortable airflow is carried down to
the floor level.
Criteria for ceiling height and number of air discharge outlets
(Ceiling height is reference value)
Number of air discharge outlets used
Standard
Ceiling
High ceiling
height
High ceiling
13-26M
30-48M
All round 4-way 3-way 2-way
flow
flow
flow
flow
All round 4-way 3-way 2-way
flow
flow
flow
flow
2.7 m 3.1 m 3.0 m 3.5 m
3.0 m 3.4 m 3.3 m 3.8 m
3.5 m 4.0 m 3.5 m -
3.2 m 3.4 m 3.6 m 4.2 m
3.6 m 3.9 m 4.0 m 4.2 m
4.2 m 4.5 m 4.2 m -
Note: Factory settings are for standard ceiling height and all-round flow.
High ceiling settings (1) and (2) are set with the remote controller by field setting.
Two selectable temperature-sensors
Both indoor unit and wired remote controller (option) contain temperaturesensors. Temperature sensing can be set at the unit or, to further improve
comfort level, closer to the target area at the wired remote control. This
feature must be set during commissioning by the technicians.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Switchable fan speed: High/Low
High setting provides maximum reach while low
setting minimises drafts.
On/Off timer
Operation starts when the preset time of the ON timer elapses and stops
when the preset time of the OFF timer elapses.
5
The condition of the drain pan and
drain water can be checked by
removing the drain plug and
intake grille.
256 mm *1
266 mm *2
Easy height adjustment
Each corner of the unit has an Adjuster Pocket that
lets you easily adjust the unit's suspended height.
Note: If the wireless remote control option is installed, a light receptor
unit is housed in one of the adjuster pockets.
All models can be installed without
using lifter because of the light weight.
Installable in
any direction
Since the orientation of
the intake grill can be
adjusted after installing,
the direction of the intake
grill lines can be unified
when multiple units
are installed.
e
en th !
p
o
t
e
Jus ke grill
inta
Drain plug
With Ultra long-life filters (option), maintenance is not required in normal shops or offices
for up to four years.
Just 256 mm high. Installable in tight
ceiling spaces (13-26M)
*1 298 mm high with 30-48M
*2 308 mm high with 30-48M
Auto-swing
Easier to maintain
dB(A)
Panel size is same for all models, FCNQ13-48M.
It is easy to maintain a neat appearance when
multiple units are installed.
950
Round Flow
Options required for specific operating environments
Ultra long-life filter
Panel spacer
Even in smoky environments where
the air conditioning is on most of
the time, the ultra long-life filter only
has to be changed once a year.
Use when only minimal space is available between drop
ceilings and ceiling slabs.
Smoky atmosphere: annual filter change
*For dust concentration of 0.3 mg/m3 (Requires separately sold Air Cleaner.)
1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year
40mm
Ordinary store or office: filter change every 4 years
Panel spacer
*For dust concentration of 0.15 mg/m3
4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 4 years
Note: Some ceiling constructions may hinder installation.
Contact your Daikin Dealer before installing your unit.
High-efficiency filter
Available in two types: 65% and 90% colorimetry.
Sealing material of air discharge outlet
Fresh air intake kit
Using this kit, a
duct can be fitted
to increase the
intake of outdoor
air.
Outside
Sealing material block air discharge openings not used in
2-way or 3-way blow.
Branch duct (direct-connection round duct)
A round duct can be attached without the need for a chamber.
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other
parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary.
Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced
through the kit is limited to 10% of the maximum airflow rate of the
indoor unit. Introducing higher quantities will increase the
operating sound and may also influence temperature sending.
A flanged port for direct connection of a round duct is
provided. An existing branch duct chamber can also be fitted
(square slit hole).
The units can be installed in the following different ways.
Drain pump is equipped as standard
accessory with 850 mm lift.
Chamber type
(without T-joint pipe and fan)
Chamber type
(with T-joint pipe and without fan)
KDDP55B160
850 mm
KDDP55B160K
Flexible duct
(procured locally)
Flexible duct
T-joint pipe
(procured locally)
T-joint pipe
Direct installation type
KDDP55X160
175 mm
Transparent drain socket
Because the drain socket is
transparent, after the drain piping
has been installed, it is easy to
check if the drain come out
through the socket.
Suction
chamber
Intake duct
Connection (procured locally)
chamber
(duct length: 4 m max.)
Suction
chamber
Intake duct
Connection (procured locally)
chamber
(duct length: 4 m max.)
Duct flange
(with insulation
material)
Intake duct
(procured locally)
Note: Use of options will increase operating sound.
Connection to a centralised control
system is available without option
6
CEILING SUSPENDED TYPE
Diffuses comfortable air
throughout the room
Upgrade to a quiet and
compact system.
Quiet operation
Sound operation has been reduced on the exposed
ceiling suspended type unit.
(220V) dB(A)
Auto-swing (up&down) brings comfort to the room.
Wide air discharge
openings produce a
spreading 100° airflow
FHNQ13/18/21/26/30/36/42/48MV1
Air is blown up to 50° in
the downward direction.
Indoor unit
High
Low
13M
43
39
18/21M
44
45
48
49
40
40
42
43
26/30M
36/42M
48M
50°
100°
Note : Anechoic chamber conversion value, measured according to JIS
parameters and criteria. During operation these values are somewhat higher
owing to ambient conditions.
Uses quiet stream fan and other quiet
technologies.
Installable on
ceilings 3.5 m high
Sound level
44/40dB(A)
High
Turbulent flow Straightening
is reduced
plate
Quiet
stream fan
Switchable fan speed: High/Low
Low
FHNQ21M
(220V)
Programme "Dry"
Dehumidification is microprocessor controlled to prevent abrupt and
uncomfortable changes in air temperature.
Wired LCD remote controller
Easier to maintain
Option
Accessory required for indoor unit.
Long-life filter lasts about 1 year*
* For dust concentration of 0.15 mg/m3
Wired LCD remote controller
Two time settings (2500 hrs and 1250 hrs) are available to match
the installation environment. Maintenance time warning is
displayed on the remote controller (filter sign).
Installation flexibility for
freedom of design
BRC1NU61
Note: Remote controller cable not
included. Cables must be
procured locally.
Non-flocking flap
Uniform height and depth. Compact design for
small-capacity models to meet tighter dimensional
constraints.
Wireless LCD remote controller
(mm)
A signal receiver must be added to the indoor unit.
BRC7NU66
Indoor unit
13M
18/21M
Height
Width
Depth
960
1,160
26/30M
36/42/48M
1,400
1,590
Condensation does not easily
form on and dirt does not
cling to non-flocking flap.
It is easy to clean.
Non-flocking flap
Easy-clean, flat surfaces
It is easy to wipe dirt off the flat side and lower
surfaces of the unit.
195
680
For all maintenance tasks, access is
from bottom surface.
Flexible installation
Signal receiver unit (Installed type)
The unit fits more snugly into tight spaces.
Wireless remote controller and signal
receiver unit are sold as a set.
Features
*2
*3
•
•
30 mm
or more
or more
*Water used in the test-run can now be drained from
the air discharge opening rather than from the side
as was formerly the case.
Others
Anti corrosion treated
heat exchangers
•
Auto-restart
•
Control features
Long-life filter
*1
Work & Servicing
Pre charged for
up to 10 m
•
Anti-bacterial air filter
Programme "Dry"
•
Cleanliness
On/Off timer
Switchable fan speed
(2 step)
•
High ceiling application
Auto swing
Remote controller
Pre charged for
up to 15 m
Comfort
30 mm
*4
All wiring and internal servicing can be done from
under the unit
Oil resistant grille
Oil-resistant plastic is used for the air suction grille.
This satisfies durability in restaurants and other
similar environments.
Note: Intended for use in salons, dining rooms, and ordinary sales
floors, this specification is not suitable for kitchens or other
harsh environments.
Pipes more easily rigged
Plastic cover is used to conceal piping work holes.
When piping work the cover is easily taken off, and after piping work
easily attached again to conceal the holes.
* Installable on max. 3.5 m high ceiling
*2Applicable to RNQ30-48M outdoor units
*3Applicable to RNQ13-26M outdoor units
*4For the outdoor units
1
7
8
DUCT CONNECTION LOW STATIC PRESSURE TYPE
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Ideal for quiet, beautiful living spaces
Suitable for condominiums and apartments,
houses and hotels
Option
FDBNQ09/13/18/21/26MV1
Unit can be mounted in the ceiling and air can be
delivered freely by duct.
Accessory required for indoor unit
Option
FDMNQ26/30/36/42/48MV1
Wired LCD remote controller
Accessory required for indoor unit
Wired LCD remote controller
BRC1C61
BRC1C61
Navigation Remote Controller
Navigation Remote Controller
(Wired Remote Controller)
(Wired Remote Controller)
BRC1E62
Sound level
Sound level
Wireless LCD remote controller
43/40dB(A)
High
BRC1E62
BRC4C64
High
Low
Signal receiver unit
(Separate type)
FDBNQ26M
(220V)
Wireless LCD remote controller
45/37dB(A)
A signal receiver must be added to the indoor unit.
A signal receiver must be added to the indoor unit.
BRC4C64
Low
Signal receiver unit
(Separate type)
FDMNQ36M
(220V)
Wireless remote controller
and signal receiver unit
are sold as a set.
Compact
Quiet operation
Small, lightweight, and easy-to-install indoor unit.
(220V) dB(A)
Indoor unit
High
Low
09/13/18M
41
43
38
40
21/26M
Wireless remote controller
and signal receiver unit
are sold as a set.
Freedom of layout
The duct system allows the efficient location
of discharge outlets in accordance with the
room layout
To prevent increased
operation sound,
avoid installing the
air suction grille
directly below the
suction chamber.
(Note)
Suction chamber
Air filter
[Duct connection]
Low
42
44
45
46
38
36
37
37
42/48M
Ordinary duct
(procured locally)
Note : 270 mm is the minimum size.
Extra height is necessary for drain piping slope and insulation.
(This feature also applies to duct connection middle static pressure type.)
When air conditioning two rooms
simultaneously, the air discharged into each
room must be circulated back to the air
conditioner. To achieve this, a ventilation duct
should be installed for each room or one of the
indicated ventilation grilles should be installed
on the partitioning wall or under the door
between the rooms.
Door-installed
ventilation grille
Wall-installed
ventilation grille
Ordinary duct
(procured locally)
Air conditioner
305 mm
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
Drain pipe connection can be done inside
the unit. Refrigerant and drain pipe outlets
are at the same opening.
325 mm
or more (Note)
Air discharge
Ventilates air through
the partitioning wall.
(See right)
Partitioning wall
Ventilation grille
Switchable fan speed: High/Low
Under-door cutout
Ventilation grille
Under-door cutout
Air intake
Note : 325 mm is the minimum size.
Extra height is necessary for drain piping slope and insulation.
Note: The under-door cutout method should be used only when there is a small volume of airflow.
Features
* Applicable when wired remote controller is used
*2Applicable when BRC1E62 is used
*3
*4
*5
•
•
•
Anti corrosion treated
heat exchangers
*2
Group control by 1 remote
controller
*2
Others
Control by 2 remote
controllers
*2
Control features
Auto-restart
*2
Pre charged for
up to 10 m
*1
Pre charged for
up to 15 m
•
On/Off timer
•
* Applicable when wired remote controller is used
*2Applicable when BRC1E62 is used
*3Applicable when BRC1C61 is used
1
Off timer (programmed)
*4
Weekly schedule timer
•
Work & Servicing
Setpoint range set
•
Remote controller
Setpoint auto reset
•
Programme "Dry"
*4
Switchable fan speed
(2 step)
*3
Comfort
Anti corrosion treated
heat exchangers
*2
Group control by 1 remote
controller
Pre charged for
up to 10 m
*2
Others
Control by 2 remote
controllers
On/Off timer
*2
* Applicable when BRC1C61 is used
*4For the outdoor units
3
Control features
Auto-restart
Off timer (programmed)
*2
Weekly schedule timer
*1
Work & Servicing
Setpoint range set
•
Setpoint auto reset
Programme "Dry"
•
Remote controller
Two selectable
temperature-sensors
Switchable fan speed
(2 step)
Comfort
Two selectable
temperature-sensors
Features
9
High
26M
30M
Duct connection is simpler with standard rear
intake chambers
(220V) dB(A)
Indoor unit
36M
or more
1
Quiet operation
*6
* Applicable to RNQ30-48M outdoor units
*5Applicable to RNQ26M outdoor units
*6For the outdoor units
4
10
OUTDOOR UNIT
Simple system provides a diverse assortment of control modes.
Control
pattern
RNQ09MV1
RNQ13MV1
RNQ18MV1
RNQ21MV1
Quiet Operation
Fitted with Super Aero Grille
RNQ26MV1
RNQ26MY1
RNQ30MV1
RNQ30MY1
RNQ36MV1
RNQ36MY1
RNQ42MY1
RNQ48MY1
Control by 1
remote
controller
(Basic system)
Control by 2
remote
controllers
For control from
2 locations such
as in room and
control room,
exits, etc.
FCNQ
Wireless remote controller
Non-polar, double-core
(max. wiring length 500 m)
Signal receiver unit installed
on indoor unit
Control by 1 wireless remote
controller and 1 wired remote
controller (See note 2, 3)
FDBNQ
Signal receiver unit installed
on indoor unit
Connects 2 wired remote
controllers (See note 1)
Group
control
For
simultaneous
control of up to
16 indoor units.
Automatic address setting function
Automatic address setting function
Signal receiver unit installed
on 1 indoor unit
Pre charged for up to 15 metres (Applies to RNQ30-48M)
If refrigerant piping length does not exceed 10m (RNQ09-26M), 15m
(RNQ30-48M), there is no need for on-site gas charging.
Control by
external
command
Operation and
surveillance is
carried out using
the contact signal
from the operation
control box in the
building
surveillance
(security) room.
Centralised
remote
control
Centralised
control of up to
64 indoor
groups from
remote location
up to 1 kilometer
away.
Optional wiring adaptor for
electrical appendices is necessary
Optional wiring adaptor for
electrical appendices is necessary
Allowed refrigerant piping length and level difference
RNQ09/13M
RNQ18/21M
Pre charged1
Max. level
difference
Equipped with scroll compressor
for quiet operation
(Applies to RNQ42-48M)
Smooth running, minimal
vibration, low operating
sound.
RNQ26M
RNQ30-48M
10 m
10 m
15 m
30 m
30 m
Max. length
15 m
50 m
(Equivalent length
50m)
(Equivalent length
70m)
20 m
30 m
Central remote controller (option)
The outer panel for the piping connection
part of the front, right side and backside
can be removed and is easier for
post-installation piping work.
Separation
available
Interlock
control
with Heat
Reclaim
Ventilator
Operation sound
Can be operated simultaneously
or independently by remote controller
(set by ventilation mode)
(In case of RNQ09-21M:220-240 V, RNQ26-36M:220 V/380 V,
240 V/415 V, RNQ42-48M:380 V, 415 V)
dB(A)
Outdoor unit
Sound level
RNQ09MV1
48
RNQ13MV1
49
RNQ18MV1
51
Heat exchange fins provided with anti-corrosion
treatment (Applies to RNQ09-26, 36-48M)
To achieve increased durability by improved resistance to salt corrosion and
atmospheric pollution, Anti corrosion treated heat exchangers (with special
acryl pretreatment) are used for the heat exchanger of the outdoor unit.
RNQ21MV1
52
RNQ26MV1/RNQ26MY1
54
RNQ30MV1/RNQ30MY1
55
Construction
RNQ36MV1/RNQ36MY1
54
Non-treated fin
Aluminium
RNQ42MY1
56
RNQ48MY1
58
Anti corrosion
treated heat
exchangers
Hydrophilic film
Aluminium
Corrosion resistant
acrylic resin
Can be operated simultaneously
by remote controller
(set by ventilation mode)
Central remote controller (option)
Zone link control
by centralised
control.
Central remote controller (option)
Heat Reclaim
Ventilator
Heat Reclaim
Ventilator
Heat Reclaim Ventilator for indoor units within
a zone are operated by interlocking Can also
be operated independently by remote
controller.
As the bottom frame is subject to corrosion,
corrosion-proof galvarium steel plate is adopted
to enhance the durability.
Heat Reclaim
Ventilator
Heat Reclaim
Ventilator
Link by remote
controller group
control.
4-direction piping offers greater
layout freedom (Applies to RNQ30-48M)
Central remote controller (option)
FCNQ only
Note:
1
Additional refrigerant charging is required if the refrigerant pipe is longer than the
length.
Durability
11
Wired remote controller
FDMNQ
Installation and
maintenance
(Applies to RNQ30-48M)
To suppress turbulence
and achieve quiet
operation, the curved
ribs of the grille are
optimised to meet the
outflow of air.
Applicable
model
Heat Reclaim Ventilator for indoor units within a
zone are operated by interlocking
Note: 1BRC1E62 can connect to BRC1E62 only.
2
It is not possible to use two wireless remote controllers.
3
BRC1E62 cannot connect to wireless remote controller.
Easily adaptable to large-scale, high-function,
centralised remote control system.
Central remote controller
DCS302CA61 (Option)
Centralised control, with setting as
simple as it is with a standard
remote controller, of up to 64 groups
(1,024 indoor units) is possible.
Unified on/off controller
DCS301BA61 (Option)
Centralised control of on/off by
group or all at once for up to 256
indoor units.
FCNQ series only
Schedule timer
DST301BA61 (Option)
Unified control of weekly schedule
for up to 1,024 indoor units.
Schedule timer sets on/off time in 1 minute units
to be executed twice a day for a week at a time.
DCS601C51 (Option)
With its high functionality, the full
colour “all-in-one” graphic controller
facilitates management of SkyAir
System in a variety of ways.
12
LCD REMOTE CONTROLLER
Optional accessory
Easy-to-read LCD remote controller allows various system
control configurations and can control multiple indoor units.
Remote controller options are shown on the page introducing each indoor unit model.
Navigation Remote Controller
(Wired Remote Controller BRC1E62)
Wired LCD remote controller
Easy to read because of large LCD screen.
The rubber switch and the
oil-resistant plastic casing are
adopted for durability.
This simple, modern designed remote controller with fresh
white colour matches your interior design. Operation is
much easier and smoother, just follow the indications on
the navigation remote controller.
NEW
Only 17 mm thick. Can be
installed either recessed or
exposed.
Wired remote controller has
built-in temperature-sensor
(Applies to wired remote controllers (BRC1C61/1E62))
Enables temperature sensing closer to target
area for improved comfort. (When using remote
control from another room, temperature-sensor in
indoor unit's air inlet must be selected.)
Facilitates maintenance and repair
All initial settings can be set from the remote
controller. After interior construction is complete,
ceiling mounted cassette type can be remotely
set without having to use stepladder access for
manual setting.
BRC1C61
Setting contents: High ceiling use, air direction, filter type, address
Clear Display
LCD wireless remote controller
Dot matrix display
Backlight
display
A combination of fine dots
enables various icons.
Large text display is easy to
see.
The wireless remote controller is
supplied in a set with a signal
receiver.
Signal receiver unit is contained
inside decoration panel or indoor
unit.
Shape of signal receiver unit
differs according to the indoor
unit.
Note: The signal receiver unit shown in the
photograph is for mounting inside
the decoration panel of the ceiling
mounted cassette type.
Easily adaptable to large-scale, high-function,
centralised remote control systems.
Installing and connecting control wiring between
SkyAir and other Daikin air-conditioning
equipment is easy.
Energy saving
Setpoint auto reset
NEW
- Even if the set temperature is changed, it returns to the preset temperature
after apreset period of time.
- Period selectable from 30min/60min/90min/120min.
Restaurant sample
Restaurant opened
Temperature is set to 27ºC
Full tables at lunchtime
Then is lowered to 24ºC for
crowded room
27 °C
Off timer (programmed)
After 30 minutes*
Automatically returns to preset
temperature (27ºC)
Returns to
27 °C
24 °C
Setpoint range set
- Saves energy by limiting the
min. and max. set temperature.
- Avoids excessive heating or
cooling.
- This function is convenient when
the remote controller is installed
at a place where any number of
people may operate it.
automatically
*Setting possible for after 30, 60, 90, and 120
minutes.
Wireless remote
controller
Signal receiver unit
(For ceiling mounted
cassette type)
Remote controller is equipped with model name
and failure display functions. This facilitates
service in the unlikely event of a malfunction.
(Applies to wired remote controller (BRC1E62))
Ceiling mounted cassette type
shares common control with Heat
Reclaim Ventilator and the other
Daikin air-conditioning units, thus
simplifying interlocking operations.
BRC7F633F
NEW
for centralised control (group control address is set automatically).
Wireless remote controller for each indoor unit type
CEILING MOUNTED CASSETTE TYPE
BRC7F633F
CEILING SUSPENDED TYPE
BRC7NU66
DUCT CONNECTION LOW STATIC PRESSURE TYPE
BRC4C64
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
BRC4C64
LCD panel shows operating status in letters, numbers, and motion.
Airflow / swing display
- Sets and saves setting for an increment of time that automatically turns off air
conditioner after a preset period of time for each time operation starts.
- Period can be preset from 30 to 180 minutes in10-minute increments.
Preset temperature / operation mode display
Programming time display
Self-diagnosis function
Displays auto-swing operating status and setting position of air discharge angle.
Displays preset room temperature and operating status (fan, dry, cool).
Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows
when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
Convenience
Weekly schedule
- 5 actions per day can be scheduled for each day
of the week.
- The holiday function will disable schedule timer
for the days that have been set as holiday.
NEW - 3 independent schedules can be set.
Multilingual display
Display is available in 11
languages.
(English, German, French, Spanish,
Italian, Portuguese, Greek, Dutch,
Russian, Turkish, and Polish).
(e.g. summer, winter, mid-season)
13
14
Abundance of functions that provide comfortable
air-conditioning in stores and offices.
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Comfort
Auto-swing
Delivers comfortable
air-conditioning to all areas, near
to and far from the
air-conditioner.
High-ceiling application
The air flow direction can be
fixed at your desited angle
by the remote controller.
Delivers air-conditioning comfort all the way down to the floor
in air-conditioning zones with high ceilings.
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Work and Servicing
Drain pump mechanism
Steeper gradient realises more
efficient condensate drainage.
High-lift is especially useful for
long lengths of drain piping.
Pre charged for up to 15 metres
If refrigerant piping length does not exceed 15 m, there is no
need for on-site gas charging.
*Applicable to RNQ30-48M.
RNQ09-26M : 10 m
Filter sign
The filter sign warns you when it is time to clean the filter.
*When using a wired remote controller the sign is displayed in the LCD.
When using a wireless remote controller the filter sign lamp illuminates on
the signal receiver unit.
Ceiling soiling prevention function
Daikin's innovative air discharge mechanism keeps airflow
away from the ceiling. Ceiling cleaning is less frequently
required.
Swing pattern selection
Long-life filter
(standard, ceiling soiling prevention)
You can freely set 2 air discharge setting by remote controller.
(1) Standard setting
Note:When units are installed on high ceilings, depending on the model,
various restrictions concerning maximum height, air discharge direction,
and choice of options may apply.
(2) Ceiling soiling prevention
setting
Two selectable temperature-sensors
Switchable fan speed
High setting provides maximum reach while low setting
minimises drafts.
Temperature-sensors are included in the indoor unit and
optional wired remote controller. Temperature sensing closer
to target area is possible to further increase the comfort level.
Use the temperature-sensor in
the indoor unit when controlling
air conditioning from another
room.
Maintenance is not required for one year.
The filter is washable and can be reused.
Control features
Auto-restart
If there is a power outage while the equipment is operating,
operations will restart in the same mode as before the power
cut when electricity is restored.
Note: Wireless remote controllers have no
temperature-sensor.
Dehumidification is microprocessor controlled to prevent
abrupt and uncomfortable changes in air temperature. Useful
for reducing uncomfortable humidity without uncomfortable
cooling of the room.
Using 2 remote controllers you can operate the equipment
locally or from a remote location.
Setpoint range set
Saves energy by limiting the minimum and maximum set
temperatures. Avoids excessive heating and cooling.
You can turn up to 16 indoor units on/off with a single remote
controller. (When using connected indoor units, the settings
must all be the same and on/off will be simultaneous.)
Enables interlocking control with external equipment such as
Heat Reclaim Ventilator.
DIII-NET communication standard
Standardly equipped interface enables connection to
centralised control system without need of an adaptor.
Off timer (programmed)
Sets and saves setting for an increment of time that
automatically turns off air conditioner after a preset period of
time for each time operation starts.
Options
High-efficiency filter unit
On/Off timer
Operation starts when the preset time of the ON timer elapses
and stops when the preset time of the OFF timer elapses.
Weekly schedule timer
Up to five operation ON/OFF settings can be programmed per
day for each day of the week. Not only can the time be set for
the operation ON setting, but also the temperature.
Cleanliness
Anti-bacterial air filter
The Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it.
15
Optional central remote controller enables centralised control of
up to 1024 indoor units (64 groups) from up to 1 kilometer away.
Interlock control
Remote Controller
Even if the set temperature is changed, it returns to the preset
temperature after a preset period of time.
Central remote control
Note: When a wireless remote controller is used, remote control by two
remote controllers is not possible.
Group control by 1 remote controller
Setpoint auto reset
Operation and surveillance is carried out using the contact
signal from the operation control box in the building
surveillance (security) room.
*An option is required.
Control by 2 remote controllers
Programme "Dry"
External command control
Two types are available: 65% and 90% colorimetry.
Ultra long-life filter
Requires no maintenance for about 4 years* (10,000h) in
stores and offices.
*For dust concentration of 0.15 mg/m3
Fresh-air intake kit
You can provide air-conditioning with fresh air from outside.
Convenient for places where a ventilation fan cannot be
installed.
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts
should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary.
Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the
kit is limited to 10% of the maximum airflow rate of the indoor unit.
Introducing higher quantities will increase the operating noise and may
also influence temperature sending.
Others
Anti corrosion treated heat exchangers
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated
heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
In high corrosive areas, regular maintenance needs to be carried out.
16
SPECIFICATIONS
CEILING MOUNTED CASSETTE TYPE
Indoor unit
Model
Name
Outdoor unit
Power supply
Cooling capacity1,2
Cooling1
Sound level (H/L)3
Unit
Dimensions
(HXWXD)
Decoration panel
Machine
weight
Unit
Decoration panel
Certified Operation range
Colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Sound
RNQ18MV1
RNQ21MV1
RNQ26MV1
RNQ30MV1
RNQ36MV1
---------
---------
---------
---------
---------
RNQ26MY1
RNQ30MY1
RNQ36MY1
RNQ42MY1
RNQ48MY1
3.8
13,000
1.24
3.07
--------5.3
18,000
1.89
2.80
6.2
21,000
2.21
2.80
Certified Operation range
Liquid (Flare)
Gas (Flare)
Drain
m3/min
cfm
dB(A)
mm
13/10
459/353
31/28
7.6
26,000
2.53
3.00
mm
kg
kg
kg
m
Max. installation level difference
44/34
298X840X840
21
24
14 to 23
0.9
1.4
Outdoor
unit
14 to 25
Ivory white
Hermetically sealed rotary type
1.8
2.2
Hermetically sealed scroll type
3.75
4.5
2.7
49
550X765X285
36
---------
51
52
595X845X300
40
--------19.4 to 46
o/ 6.4
49
---------
54
735X825X300
56
56
55
990X940X320
77
74
o/ 12.7
54
103
103
21 to 46
o/ 9.5
56
1,345X900X320
--------107
58
--------111
o/ 15.9
VP25 (I.Do/ 25XO.Do/ 32)
o/ 18.0 (Hole)
30
10
15
30
(Equivalent length 50)
o/ 26.0 (Hole)
50
(Equivalent length 70)
20
30
Outdoor unit
RNQ09MV1
RNQ13MV1
RNQ18MV1
RNQ21MV1
RNQ26MV1
Y1
---------
---------
---------
---------
RNQ26MY1
6.2
21,000
2.38
2.60
3 Phase, 380–415 V, 50 Hz
7.6
26,000
2.62
2.90
dB(A)
mm
V1
Y1
Certified Operation range
Liquid (Flare)
Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
kg
°CDB
mm
mm
mm
mm
m
26
FDBNQ26MV1
1 Phase, 220–240 V, 50 Hz
--------3.8
13,000
1.28
2.97
2.7
9,200
0.86
3.14
5.2
17,700
2.06
2.52
----------
13/11
459/388
18/15
635/530
2.0
41/38
260X900X580
25
43/40
260X1,300X580
32
14 to 23
14 to 25
0.65
0.9
Ivory white
Hermetically sealed rotary type
1.4
1.8
2.2
0.9
(Charged for 10 m)
1.2
(Charged for 10 m)
1.4
(Charged for 10 m)
1.5
(Charged for 10 m)
2.0
(Charged for 10 m)
48
49
51
52
54
735X825X300
56
56
21 to 46
o/ 9.5
550X765X285
35
----------
595X845X300
36
----------
40
----------
49
----------
19.4 to 46
o/ 6.4
o/ 12.7
3/4B (I.Do/ 21.6XO.Do/ 27.2)
o/ 18.0 (Hole)
o/ 9.5
o/ 15.9
30
(Equivalent length 50 m)
30
m
10
15
Both liquid and gas piping
20
Cooling1
Colour
Airflow rate (H/L)
Type
Motor output
Piping
connections
Liquid (Flare)
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
RNQ21MV1
RNQ26MV1
RNQ30MV1
RNQ36MV1
---------
---------
---------
---------
RNQ26MY1
RNQ30MY1
RNQ36MY1
RNQ42MY1
RNQ48MY1
3.8
13,000
1.58
2.40
--------5.3
18,000
2.04
2.60
kg
Sound level3
Certified operation range
RNQ18MV1
---------
kW
Refrigerant charge (R-410A)
Dimensions (HXWXD)
Machine weight
RNQ13MV1
Y1
m3/min
cfm
dB(A)
mm
kg
°CWB
Sound level (H/L) (220 V)3
Colour
Compressor
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
V1
V1
Y1
kW
Btu/h
kW
W/W
Outdoor unit
Dimensions (HXWXD)
Machine weight
Certified operation range
V1
Y1
dB(A)
mm
kg
kg
°CDB
mm
mm
mm
mm
16/565/43/39
195X960X680
24
0.9
6.2
21,000
2.38
2.60
22-23/19-20
777-812/671-706
44/40
195X1,160X680
26
14 to 23
7.6
26,000
2.65
3 Phase, 380–415 V, 50 Hz
8.8
10.4
12.3
30,000
35,000
42,000
4.51
3.07
3.64
2.73
2.86
2.87
White
26-27/22-23
918-953/777-812
45/40
195X1,400X680
32
42-44/24-26
38-40/23-25
1,341-1,412/812-883
1,483-1,553/847-918
48/42
49/43
195X1,590X680
35
14 to 25
Ivory white
Hermetically sealed rotary type
1.8
2.2
1.4
Hermetically sealed scroll type
3.75
4.5
2.7
51
49
550X765X285
36
---------
52
595X845X300
40
--------19.4 to 46
o/ 6.4
49
---------
54
54
55
735X825X300
990X940X320
56
56
77
74
o/ 12.7
56
Power consumption
COP
Colour
Indoor
unit
Outdoor
unit
--------107
VP20 (I.Do/ 20XO.Do/ 26)
30
(Equivalent length 50)
30
10
15
20
Both liquid and gas piping
--------111
Certified Operation range
Liquid (Flare)
Gas (Flare)
Indoor unit
Drain
Outdoor unit
Max. interunit piping length
o/ 26.0 (Hole)
50
(Equivalent length 70)
RNQ30MV1
RNQ36MV1
---------
---------
RNQ30MY1
RNQ36MY1
RNQ42MY1
RNQ48MY1
kg
°CDB
mm
mm
mm
mm
m
30
Max. installation level difference
Heat insulation
48
FDMNQ48MV1
RNQ26MV1
dB(A)
mm
V1
Y1
42
FDMNQ42MV1
RNQ26MY1
Rated external static pressure3
mmH2O
Sound level (H/L) (220 V)4
dB(A)
mm
Dimensions (HXWXD)
kg
Machine weight
Certified Operation range
°CWB
Colour
Type
Compressor
Motor output
kW
Refrigerant charge
kg
(R-410A)
Sound level4
Dimensions (HXWXD)
Machine weight
36
FDMNQ36MV1
Y1
m3/min
cfm
Airflow rate (H)3
Piping
connections
o/ 15.9
o/ 18.0 (Hole)
58
Fan
Cooling1
30
FDMNQ30MV1
V1
V1
Y1
kW
Btu/h
kW
W/W
Outdoor unit
Cooling capacity1,2
1,345X900X320
103
103
21 to 46
o/ 9.5
Outdoor unit
Power supply
14.1
48,000
5.51
2.56
26
FDMNQ26MV1
Indoor unit
Model
Name
1.2
1.4
1.5
2.0
1.9
3.2
2.7
3.2
(Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m)
m
m
---------
1 Phase, 220–240 V, 50 Hz
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
17
V1
Rated external static pressure3
mmH2O
Sound level (H/L) (220 V)4
dB(A)
mm
Dimensions (HXWXD)
kg
Machine weight
Certified Operation range
°CWB
Colour
Type
Compressor
Motor output
kW
Refrigerant charge
kg
(R-410A)
Piping
connections
26
30
36
42
48
13
18
21
FHNQ13MV1 FHNQ18MV1 FHNQ21MV1 FHNQ26MV1 FHNQ30MV1 FHNQ36MV1 FHNQ42MV1 FHNQ48MV1
Indoor unit
Power consumption
COP
Outdoor
unit
21
FDBNQ21MV1
Both liquid and gas piping
Cooling capacity1,2
Indoor
unit
18
FDBNQ18MV1
m3/min
cfm
Airflow rate (H/L)3
Max. installation level difference
Heat insulation
CEILING SUSPENDED TYPE
Power supply
Cooling1
Sound level4
Dimensions (HXWXD)
Machine weight
1.2
1.4
1.5
2.0
1.9
3.2
2.7
3.2
(Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m)
Heat insulation
Model
Name
Fan
44/36
5.5
mm
mm
m
Max. interunit piping length
Power consumption
COP
Colour
Indoor
33/22.5
1,165/794
13
FDBNQ13MV1
V1
Y1
kW
Btu/h
kW
W/W
Outdoor unit
Cooling capacity1,2
50X950X950
19.5
°CWB
kW
32/20
1,130/706
43/32
Outdoor unit
Power supply
14.1
48,000
5.04
2.80
09
FDBNQ09MV1
Indoor unit
Model
Name
unit
21/13.5
741/477
35/28
256X840X840
°CDB
mm
mm
Indoor unit
Outdoor unit
3 Phase, 380–415 V, 50 Hz
8.8
10.6
12.5
30,000
36,000
42,600
4.15
2.73
3.31
3.01
3.22
3.20
----------
dB(A)
mm
V1
Y1
---------
1 Phase, 220–240 V, 50 Hz
Fresh white
kg
level3
Dimensions (HXWXD)
Machine weight
Piping
connections
RNQ13MV1
Y1
Unit
Decoration panel
Airflow rate (H/L)
Outdoor
unit
V1
V1
Y1
kW
Btu/h
kW
W/W
Outdoor unit
Power consumption
COP
Indoor
Colour
unit
DUCT CONNECTION LOW STATIC PRESSURE TYPE
13
18
21
26
30
36
42
48
FCNQ13MV1 FCNQ18MV1 FCNQ21MV1 FCNQ26MV1 FCNQ30MV1 FCNQ36MV1 FCNQ42MV1 FCNQ48MV1
m
7.6
26,000
2.62
2.90
23
812
8.5
42/38
305X1,350X680
43
--------1 Phase, 220–240 V, 50 Hz
3 Phase, 380–415 V, 50 Hz
8.8
10.6
12.3
14.1
30,000
36,000
42,000
48,000
3.53
4.49
5.56
3.03
3.00
2.74
2.54
2.90
---------42
37
1,306
1,483
9.8
8.0
44/36
45/37
46/37
305X1,550X680
52
14 to 25
Ivory white
Hermetically sealed rotary type
Hermetically sealed scroll type
2.2
2.7
3.75
4.5
2.0
(Charged for 10 m)
1.9
(Charged for 15 m)
3.2
(Charged for 15 m)
2.7
(Charged for 15 m)
3.2
(Charged for 15 m)
54
735X825X300
56
56
55
990X940X320
77
74
54
56
1,345X900X320
---------107
58
o/ 18.0 (Hole)
30
(Equivalent length 50 m)
20
103
103
21 to 46
o/ 9.5
o/ 15.9
3/4B (I.Do/ 21.6XO.Do/ 27.2)
o/ 26.0 (Hole)
50
(Equivalent length 70 m)
---------111
30
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
Please see fan characteristic document in detail.
4
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
18
OPTIONS
Indoor unit
Indoor unit
CEILING MOUNTED CASSETTE TYPE
Name of option
CEILING SUSPENDED TYPE
Remark
Decoration panel
Sealing material of air discharge outlet
Panel spacer
Fresh air
Chamber
type
intake kit1
Without T-joint pipe and fan
With T-joint pipe, without fan
Direct installation type
Chamber connection kit2
Insulation kit for high humidity
(Colorimetric method 65%)
High-efficiency filter
(including chamber)
(Colorimetric method 90%)
Replacement
(Colorimetric method 65%)
high-efficiency filter
(Colorimetric method 90%)
Filter chamber
Replacement long-life filter
Ultra long-life filter
Replacement ultra long-life filter
Branch duct chamber
Wireless type
Cooling only
Remote controller
Wired type3
Navigation Remote Controller
Wired type3
Central remote controller4
Unified ON/OFF controller4
Schedule timer4
Touch Controller4
Adaptor for wiring5
Wiring adaptor for electrical appendices5
Installation box for adaptor PCB
Remote sensor
Kit name
FCNQ13MV1 FCNQ18MV1 FCNQ21MV1 FCNQ26MV1 FCNQ30MV1 FCNQ36MV1 FCNQ42MV1 FCNQ48MV1
BYCP125K-W1
KDBH55K160F
KDBP55H160FA
KDDP55B160
KDDP55B160K
KDDP55X160
KKSJ55KA160
KDTP55K160
KDTP55K80
KAFP556B160
KAFP556B80
KAFP557B160
KAFP557B80
KAFP552B160
KAFP552B80
KAFP553B160
KAFP553B80
KDDFP55B160
KAFP551K160
KAFP55B160
KAFP55H160H
KDJP55B80
KDJP55B160
BRC7F633F
BRC1C61
BRC1E62
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP1C63
KRP4AA53
KRP1H98
KRCS01-4B
Note: 1Refer to page 6 for the details.
2
Required for installing high-efficiency filter or ultra long-life filter.
3
Wiring for wired remote controller to be procured locally.
4
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
5
Installation box for adaptor PCB (KRP1H98) is necessary.
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
Panel spacer
Operation control related
Wireless remote controller
Auxillary function related
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (direct mount)
High-humidity operation kit
Filter related
Panel spacer1
High-efficiency filter2
Ultra-long-life filter2
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o
1
Panel/grille related
Replacement long-life filter
L-type piping kit (for upward direction)
Remote controller
o
o
o
x
o
o
o
o
o
o
o
Resin net
Wireless type
Wired type1
Kit name
FHNQ13MV1 FHNQ18MV1 FHNQ21MV1 FHNQ26MV1 FHNQ30MV1 FHNQ36MV1 FHNQ42MV1 FHNQ48MV1
KAF501DA80
KAF501DA112
KAF501DA160
KAF501DA56
KHFJ5F60
KHFP5MA160
KHFJ5F50
BRC7NU66
BRC1NU61
Note: 1Wiring for wired remote controller to be procured locally.
DUCT CONNECTION LOW STATIC PRESSURE TYPE
Name of option
Remote controller
Navigation Remote Controller
Remark
FDBNQ09MV1
FDBNQ13MV1
Wireless type
Wired type1
Wired type1
Kit name
FDBNQ18MV1
BRC4C64
BRC1C61
BRC1E62
FDBNQ21MV1
FDBNQ26MV1
FDMNQ42MV1
FDMNQ48MV1
Note: 1Wiring for wired remote controller to be procured locally.
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Name of option
Remote controller
Navigation Remote Controller
Remark
Wireless type
Wired type1
Wired type1
FDMNQ26MV1
FDMNQ30MV1
Kit name
FDMNQ36MV1
BRC4C64
BRC1C61
BRC1E62
Outdoor unit
Name of option
Central drain plug
All round flow 4-way flow
Optional accessory parts
Remark
Note: 1Wiring for wired remote controller to be procured locally.
Round flow type: List of optional parts required to achieve different flow patterns
Independently installable optional parts
Name of option
o
o
x
x
o
o
o
o
x
o
o
o
High-humidity
operation kit
High-efficiency
filter2
Ultra-long-life
filter2
x
o
x
o
o
o
o
o
x
o
o
o
o
x
x
x
x
x
High-humidity
operation kit
High-efficiency
filter2
x
o
x
o
x
x
x
x
x
x
x
High-humidity
operation kit
High-efficiency
filter2
Ultra-long-life
filter2
x
x
x
x
x
x
o
o
o
Kit name
------------RNQ09MV1 RNQ13MV1 RNQ18MV1 RNQ21MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1
------------------------RNQ26MY1 RNQ30MY1 RNQ36MY1 RNQ42MY1 RNQ48MY1
------------KKP014A4
KKPJ5F180
3-way flow 2-way flow
Optional accessory parts
Independently installable optional parts
Panel/grille related
Panel spacer1
Operation control related
Wireless remote controller
Auxillary function related
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (direct mount)
High-humidity operation kit
Filter related
Ultra-long-life filter2
Panel spacer1
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o3
o3
o3
o3
x
o3
o
o
o
o
o3
o
x
x
o
o3
o
x
o
o
Ultra-long-life
filter2
o3
o
o
o
x
Branch duct connection
Optional accessory parts
Independently installable optional parts
duct1
Branch
(Chamber type)
(Round duct type)
1-way branch / unit 3-way flow
2-way branch / unit 2-way flow
1-way branch / unit 2-way flow
Panel spacer1
o
x
x
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o
o
o
o
o
o
o
o
o
4
4
4
1
In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check
whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
2
Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.
3
It is not possible to use panel spacers in a 2-way flow installation.
4
It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
19
20
DIMENSIONS
(Unit: mm)
CEILING MOUNTED CASSETTE TYPE
CEILING SUSPENDED TYPE
157
350
A
157
350
2x100=200
25
213
213
C/L
90
183
C arrow view
Connection position
of branch duct
(round shape type)
Connection position
of fresh air intake kit
(direct installation type)
90
80
ø10
(kn 0
ock
hole
)
90
196
ø10
(kn 0
ock
hole
)
Hanging bolt
4-M8~M10
1
5
55
13
6
4
B
30 or more
(Service space)
(Service space)
Drain pipe connection VP20
(For left piping)
6
80
A
35 or less
(Note 4)
Connection position
of branch duct
(square-shaped type)
Notes:
1
Sticking location for manufacture's label
manufacture's label for indoor unit:
Suction grille inner side's electric components box's lid surface
manufacture's label for decoration panel :
Decoration panel's corner decoration cover inner surface
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller
in detail.
3
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4
Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less
between the indoor unit and the ceiling opening so that
the panel overlap allowance can be ensured.
5
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
7
5
105
4
Notes:
1
Location of unit's Name plate : Bottom of fan housing inside the suction grille.
2
In case of using wireless remote controller, this position will be a signal receiver.
Refer to the drawing of wireless remote controller in detail.
3
The remote control code is the standard <about 3m outside the machine> attached.
(0.5mm2x2 wicks O.D. 5.4)(It is not attached to VRV.)
115 60
65
DUCT CONNECTION LOW STATIC PRESSURE TYPE
[FDBNQ09/13/18MV1]
1
2
3
4
5
6
7
8
9
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Power-source wiring and a unit
wiring connection
Connection wiring/remote control
wiring connection
Air-outlet
Suction grille
Corner decoration cover
Drain hose (accessory)
900
704
151
3
3
8
300 or more
Service space
500
10-M4 Holes
(All Around)
1
2
3
4
2
4
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Ground terminal
29
1
260
6
7
12-M4 Holes
(All Around)
5
6
7
8
150
219
236
5
110
170
228
684
664
3×P150=450
134
107
164
260
50
126
755
(Suspension bolt pinch)
21
Air discharge grille
Air suction grille
Air filter
Gas pipe connection
Liquid pipe connection
Drain pipe connection
Earth terminal (Inside the electric components box)
Suspension bracket
Backward pipe and wiring connection opening lid
Upward pipe and wiring connection opening lid
Right side pipe connection
Left back drain pipe connection
Left side drain pipe connection
Right side drain pipe connection
Hole of wall for taking out in pipe back
Upward drain pipe connection
Upward gas pipe connection
Upward liquid pipe connection
10 or more
157
350
200mm
or more
1500mm or more
The necessary space is 500mm or more when the
air-outlet is blocked with the accessory.
Moreover when the corner areas are blocked
(both right and left of the blocked air outlet),
the necessary space is 200mm or more.
14
271
130
95
167
93
29
60
42
256
1500mm
or more
1500mm
or more
2
170
167
2
5
3
1500mm or more
500
(Suspension bolt pinch)
137
1
27-M4 Prepared hole
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
C arrow view
55
4
35 or less
(Note 4)
Connection position
of branch duct
(round shape type)
55
55
Brand name plate
(Note.2)
580
280
330
840
81 2x100=200 85
160
64
50
o/ 45
The Front
Obstacle
Floor side
317
157
105
160
298
125
165
20 C/L
350
3
1500 or more 67
(required space) 160
From the floor side 2500 or more
For height installation
Hanging bolt
4-M8~M10
Connection position
of branch duct
(round shape type)
55
Connection position
of branch duct
(square-shaped type)
150
55
95
167
840
340
80 2x100=200 80
160
175
29
55
50
40
160
288
10
850
Adjustable(0~675)
16-M4 Prepared hole
Position : Hole of wall for taking out in piping back
(View from the front)
80
90
155
30 or more
[FCNQ30-48MV1]
Required space
200mm or more
11
40
680
80
[FCNQ30-48MV1]
105
15
A
(Hanging position)
5
(Required space)
67
95
29
157
350
2x100=200 80
25
160
80
124
35 or less
(Note 4)
Connection position
of branch duct
(square-shaped type)
Connection position
of branch duct
(round shape type)
Connection position
of fresh air intake kit
(direct installation type)
90
256
C/L
80
95
110
124
60
130
150
20-M4 Prepared hole
5
160
65
Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket
16
10
151
127 3×P.150=450
674
688
704
900
52
16
10
280
330
55
167
93
145 60
Position slit hole for taking out in piping back
(View from the front)
10
225
275
2
840
81 2x100=200 85
124
64
50
42
105
3
127
60
8
Connection position
of branch duct
(square-shaped type)
20-M4
Prepared hole
9
5
135 (Required space)
1550 1590
40 135
FHNQ48MV1
50
195
B arrow view
36
1550 1590
185
1550 1590
FHNQ42MV1
192
FHNQ36MV1
Connection position
of branch duct
(square-shaped type)
167
157
350
102
1360 1400
160
1360 1400
FHNQ30MV1
12
85
1120 1160
FHNQ26MV1
210
1120 1160
FHNQ21MV1
260
FHNQ18MV1
16-M4 Hole
(Hanging
position)
960
170
105
90
58
18 17 16 142
300
275
1
55
35 or less
(Note 4)
Connection position
of branch duct
(round shape type)
157
4
920
[FCNQ30-48MV1]
160
124
109
95
Connection position
of branch duct
(square-shaped type)
20-M4
Prepared hole
1500 or more
(required space) 160
From the floor side 2500 or more
For height installation
350
FHNQ13MV1
For height installation
[FCNQ13-26MV1]
[FCNQ13-26MV1]
125
165
256
50
40
20 C/L
Hanging bolt
4-M8~M10
Connection position
of branch duct
(round shape type)
2x100=200
160
C/L
160
67
7
95
110
124
340
80 2x100=200 80
124
B
Drain Connection
Side
16-M4 Prepared hole
55 Connection position
of branch duct
(square-shaped type)
175
850
Adjustable(0~675)
B arrow view
6
Connection position
of branch duct
(square-shaped type)
A arrow view
840
A
Connection position
85 of branch duct
(round shape type)
93
160
124
C
81
16-M4 Hole
157
350
950
780(Hanging bolt pitch)
860~910(Ceiling opening space) (Note 4)
Pipe Connection
Side
[FCNQ13-26MV1]
160
246
10
Note 2
8
420
55
2x100=200
124
C/L
81
950
Connection position
85 of branch duct
(round shape type)
95
110
860~910(Ceiling opening space) (Note 4)
300
or less 710(Hanging bolt pitch)
420
9
[FHNQ13/18/21/26/30/36/42/48MV1]
[FCNQ30-48MV1]
300 or more
(Required space)
[FCNQ13-26MV1]
From the floor side 2500 or more 155
[FCNQ13-48MV1]
B
29
95
[FCNQ13-48MV1]
Note: 1Location of unit's Name Plate: Chamber cap
22
DIMENSIONS
(Unit: mm)
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
DUCT CONNECTION LOW STATIC PRESSURE TYPE
[FDBNQ21/26MV1]
[FDMNQ30/36/42/48MV1]
1550
300 or more
5
6
7
8
Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket
Note: 1Location of unit's Name Plate: Chamber cap
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
381
263
280
10
7
150
305
6
1
74
5
16
29
4
274
152
827
18-M4 Holes
(All Around)
1
2
3
4
51
2
212
50
18-M4 Holes
(All Around)
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Ground terminal
7×P150=1050
123
206
175
305
219
236
7
10
260
228
6
1
150
29
1550
1353
1337
1321
7×P150=1050
151
8
16
1334
1314
52
700
16-M4 Holes
(All Around)
170
110
50
107
260
164
134
102
1088
1074
6×P.150=900
4
5
126
1403
(Suspension bolt pinch)
1300
1104
10
16
2
Service space
55
8
151
1084
1064
6×P150=900
146
Service space
126
1155
(Suspension bolt pinch)
16
8
1
2
3
4
600
(Suspension bolt pinch)
116
427
680
3
55
317
580
3
3
271
500
(Suspension bolt pinch)
137
3
300 or more
151
1353
10 or more
151
167
1300
1104
20-M4 Holes
(All Around)
5
6
7
8
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Ground terminal
Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket
Note: 1Location of unit's Name Plate: Chamber cap
OUTDOOR UNIT // RNQ09/13MV1
[FDMNQ26MV1]
4-Hole for anchor bolts
(M8 or M10)
Drain outlet
(I.D. 15.9 hose for connection)
574
311
381
146
Handle
285
51
2
196
In case of removing
stop valve cover
29
1
6
74
16
10
727
Wall height on air outlet side
=less than 1200
7
22
Gas stop valve
( 15.9CuT for RNQ13)
( 9.5CuT for RNQ09)
150
5
165
550
Wiring
inlet
4
152
212
274
305
206
175
123
50
50
50
50
100
Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket
300
5
6
7
8
150
20-M4 Holes
(All Around)
100
23
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Ground terminal
Liquid stop valve
( 6.4CuT)
Service
port
305
7×P150=1050
1350
1153
1137
1121
7×P150=1050
Minimum space for air passage
1
2
3
4
Manufacture’s
label
105
151
8
16
1134
1114
18-M4 Holes
(All Around)
Brand name label
63
126
1203
(Suspension bolt pinch)
50
765
150
263
280
8
12
8
Service space
55
427
680
3
116
600
(Suspension bolt pinch)
3
105.5
490
13
300 or more
151
29.5
1350
1153
Note: 1Location of unit's Name Plate: Chamber cap
24
DIMENSIONS
(Unit: mm)
OUTDOOR UNIT // RNQ18/21MV1
OUTDOOR UNIT // RNQ30MV1, RNQ30MY1
30
Hole for anchor bolt 4-M12
573.5
320
91
160
4-Hole for anchor bolts
(M8 or M10)
20
7
30
38
300
326
342
131
55
78
300
37
845
350
(345∼355)
Drain outlet
I.D. 18 hose for connection
620
30
Name plate
Brand name label
160
940
Earth terminal
in switch box
Wiring inlet
4
3
7
60
1
5
6
19
55
223
80
145
13
68
300
285
279
260
161
150
50
1 Gas pipe connection
2 Liquid pipe connection
50
3 Service port
4 Grounding terminal
36
61
300
50
5 Refrigerant piping intake
6 Power supply wiring intake
262
416
595
OUTDOOR UNIT // RNQ26MV1, RNQ26MY1
30
Hole for anchor
bolt 4-M12
96
140
620
140
900
30
25
10
30
300
330
350
41
320
580
2
48
350
325
61
78
(345~355)
825
36
7 Control wiring intake
8 Drain pipe connection
OUTDOOR UNIT // RNQ36MV1, RNQ36/42/48MY1
Drain outlet
I.D. 15.9 hose for connection
124
67
16
5
50
52
16
8
300
100
90
53
84
19
142
Wall height on air outlet side
=less than 1000
5
55
340
53
89
53
Gas stop valve
( 15.9CuT for RNQ21MV1)
( 12.7CuT for RNQ18MV1)
7
Minimum space for air passage
6
95
95
339
60
20
144
89
Service port
6
5
105
Liquid stop valve
( 6.4CuT)
7
95
990
595
2
4-Hole for anchor bolts
(M8 or M10)
4
Brand name label
Name plate
Earth terminal
in switch box
Wiring inlet
2
1
3
55
5
54
80
95
223
84
95
55
435
19
145
16
58
70 102 117
350
16
5
45
25
6
52
13
67
8
100
50
350
100
350
50
19
142
71
50
7
6
410
95
89
54
89
Wall height on air outlet side
=less than 1200
Gas stop valve
( 15.9CuT)
100
Minimum space for air passage
18
30
24
Service port
155
160
7
5
5
60
Liquid stop valve
( 9.5CuT)
6
53
89 64
1345
735
7
376
191
1
2
3
4
5
6
7
8
Gas pipe connection
Liquid pipe connection
Service port (in the unit)
Grounding terminal
Refrigerant piping intake
Power supply wiring intake
Control wiring intake
Drain pipe connection
26
DIMENSIONS
Installation service space for outdoor unit
(Unit: mm)
For RNQ30-48MV1/Y1
REMOTE CONTROLLER
Wireless type
(Unit: mm)
Remote controller dimensions
1 When there is an obstruction on the inlet side
BRC7F633F BRC4C64
2 When there is an obstruction on the outlet side
CEILING MOUNTED CASSETTE TYPE <Round Flow>
• Receiver installation procedure
Remote controller holder
installation procedure
<Installation to wall surface>
Transmitting part
• Receiver detail
1) When the overhead space is open
1) When the overhead space is open
Receiver
Refrigerant
piping side
157
1. For single unit installation
Liquid crystal
remote controller
(Wireless)
When there is an
obstruction only
on the inlet side
Decoration panel
Drain piping
side
1. For single unit installation
50
Remote controller
holder
0
10
CEILING SUSPENDED TYPE
62
17.5
Receiver installation procedure
The Front
Receiver detail
mo
or
re
2. For multiple units installation
(more than two units)
rm
ore
10
0
mo or
re 10
0
mo or
re
When there are obstructions
on both sides
Receiver
0o
BRC7NU66
100
or m
ore
100
or m
Remote controller
(Wireless)
2-5x9 Slot
70
0.5
35
18
More than 90
(Srevice space)
18.1
(Ceiling opening)
120
54
Note :
Do not install more than 3
receivers in the vicinity of one
another.
With 4 or more units, there is
always the possibility of
malfunction
49
(Ceiling opening)
10
00
re
20
0o
rm
30
0o
r
re
mo
0
50
2. For multiple units installation
(more than two units)
50
2) When there is an obstruction
in the overhead space
or
0o
mo
r le
re
ss
Conduit
42
117
84
120
38
When there is an
obstruction on the
inlet side
0~5
Through hole
Cord
outlet
hole
17
CONTROL BOX
Note) 1. Remote controller cord and
staple are not attached.
they are field supplied
parts.
(fl12~fl16)
( Distance between
remote controller
and control box )
Specifications of cord
Type
Vinyl cord with sheath or cable (Insulated thickness: 1 mm or more)
Size
0.75~1.25 mm2
Total length
500 m
* Countries requiring EMC: Shield wire (insulated thickness: 1 mm or more)
BRC1E62
• Installation method
Lower case
A Exposed cord
Top left
outlet
B Embedded cord
Staple
Condit
C Embedded cord
(use switch box)
19
19
42
Top center
outlet
Operation
lamp
(Green)
10
When there are obstructions
on the inlet side and
both sides
84
84
40
0
or
s
les
50
150
or m
0o
1
An obstruction
in the overhead
space
84
50
An obstruction
in the overhead
space
10
0o
r le
0o
rm
or
ss
0
00
or
re
mo
e
3 When there are obstructions on both
the inlet and outlet sides
(When the obstruction on the outlet side is higher than the
unit itself)
1) When the overhead space is open
(There is no limit to the height of the obstruction on the
outlet side.)
ore
150
e
or
rm
ore
40
1. For single unit installation
o
50
or m
1
48.5
Left outlet
19
Lower case portion
Note)2
28
Through hole
Switch box for one switch
( 8- 10)
ex.) KJB111A
(optional accessory)
Lower case
Note)
1. Remote controller cord and staple are not attached. They are field
supplied parts.
Specifications of cord
BRC1NU61
6
44.5
20
Note)
The dimension of hole.
25
Type
Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
Size
0.75~1.25 mm2
Total length
500 m
46
0~5
Switch box for two switch (Between remote
ex.) KJB211A
controller and
(optional accessory)
control box)
Switch box
portion
[field supplied part]
2.If the hole size is too large or the location
is not proper, the hole may come out from
the remote controller.
2. For multiple units installation (more than two units)
When there are obstructions
on the inlet side and
both sides
An obstruction
in the overhead
space
10
10
0
mo or
re
50
0o
r le
ss
10
00
or
mo
L
H
2. For multiple units installation
(more than two units)
0o
0
50 ore
m
or
10
0
mo or
re 10
0
mo or
re
rm
ore
re
24
10
25 20
41
a
38
41.5
A
A
20
0o
4
R2
rm
ore
77
B
A
111
B
17
13
119
22 25
A
B
Hole type
A
B
0
10 ore
m
or
H
5X15 oblong hole
L
28
23
48.5
46
1000 or more
19
L
Code outlet hole
5X7 oblong hole
rm
ore
1. For single unit installation
17
18
23 28
46
An obstruction
in the overhead space
H
17
Staple
C Exposed body, embedded code
1000 or more
B Exposed body, embedded cord
1000 or more
A EXposed body, exposed cord
120
ss
mo
ore
Remote controller installation procedure
Upper case
r le
10
0
mo or
re
BRC1C61
17
0o
ore
1. For single unit installation
Remote controller dimensions
120
50
rm
An obstruction
in the overhead space
or
(field Supplied parts)
120
2) When there is an obstruction
in the overhead space
10
0
mo or
re 10
0
mo or
re
When there are
obstructions on
both sides
Switch box
Wired type
rm
2. For multiple units installation
(more than two units)
Service space for ceiling
installation
72
83.5
106
Remote controller
holder
0o
0o
1000 or more
115.5
Receiver detail
10
ore
0
10
ore
1000 or more
Remote controller holder
installation procedure
<Installation to wall surface>
Transmitting part
0
30
or
mo
re
L
H
00
10 ore
m
or
0
30 ore
m
or
a (mm)
6
10
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
27
28
MEMO
29
30