PCSVN1420A Warning Ask a quali ed installer or contractor to install this product. Do not try to install the product by yourself. Improper installation can result in water or refrigerant leakage, electrical shock re or explosion. Use only those parts and accessories supplied or speci ed by Daikin. Ask a quali ed installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical re or explosion. sho Read the user's manual carefully before using this product. The user's manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Đại lyù phaân phoái: TRUNG TÂM DICH VU KHÁCH HÀNG Miễn phí cöôùc cuoäc goïi notice. c All rights reserved 07/14 SS New wide lineup of SkyAir series. Product Lineup Series Btu/h kW 09 13 18 21 1 26 30 36 42 2 48 2,3 9,200 13,000 18,000/17,700* 21,000 26,000 30,000 36,000/35,000* 2.7 3.8 5.3/5.2*1 6.2 7.6 8.8 10.6/10.4*2 42,600/42,000* 12.5/12.3*2,3 48,000 14.1 FCNQ13MV1 FCNQ18MV1 FCNQ21MV1 FCNQ36MV1 FCNQ42MV1 FCNQ48MV1 RNQ13MV1 RNQ18MV1 RNQ21MV1 RNQ42MY1 RNQ48MY1 FHNQ13MV1 FHNQ18MV1 FHNQ21MV1 FHNQ42MV1 FHNQ48MV1 RNQ13MV1 RNQ18MV1 RNQ21MV1 RNQ42MY1 RNQ48MY1 FDBNQ09MV1 FDBNQ13MV1 FDBNQ18MV1 FDBNQ21MV1 RNQ09MV1 RNQ13MV1 RNQ18MV1 RNQ21MV1 CEILING MOUNTED CASSETTE TYPE Round Flow Indoor unit Outdoor unit FCNQ26MV1 RNQ26MV1 RNQ26MY1 FCNQ30MV1 RNQ30MV1 RNQ30MY1 RNQ36MV1 RNQ36MY1 CEILING SUSPENDED TYPE Pair Indoor unit Outdoor unit DUCT CONNECTION FHNQ26MV1 RNQ26MV1 RNQ26MY1 FHNQ30MV1 RNQ30MV1 RNQ30MY1 FHNQ36MV1 RNQ36MV1 RNQ36MY1 LOW STATIC PRESSURE TYPE Indoor unit Outdoor unit FDBNQ26MV1 RNQ26MV1 RNQ26MY1 MIDDLE STATIC PRESSURE TYPE FDMNQ26MV1 Indoor unit Outdoor unit FDMNQ42MV1 FDMNQ48MV1 RNQ26MV1 RNQ26MY1 RNQ30MV1 FDMNQ30MV1 RNQ30MY1 RNQ36MV1 FDMNQ36MV1 RNQ36MY1 RNQ42MY1 RNQ48MY1 RNQ26MV1 RNQ26MY1 RNQ30MV1 RNQ30MY1 RNQ36MV1 RNQ36MY1 RNQ42MY1 RNQ48MY1 OUTDOOR UNIT Outdoor unit RNQ09MV1 RNQ13MV1 RNQ18MV1 RNQ21MV1 Note : *1Applicable to FDBNQ series. *2Applicable to FHNQ series. *3Applicable to FDMNQ series. 1 2 CEILING MOUNTED CASSETTE TYPE Round Flow Avoids uneven temperature and discomfort caused by drafts. Cassette air conditioner with 360° uniform airflow sets the standard Comfort enhanced by Round Flow! FCNQ13/18/21/26/30/36/42/48MV1 360° airflow Air movement is gentle with Round Flow With uniform temperature distribution Enhanced Comfort 360° airflow can maintain comfort even if air discharge speed is lower. Airflow distribution Creates uniform comfort throughout the space If you raise the set temperature by 1 to 1.5°C,and velocity is decreased by 25%, you still obtain the same feeling temperature and comfort. Sound level 43/32dB(A) High Low FCNQ36M Option Accessory required for indoor unit. Greater comfort Improved energy saving (220V) Wired LCD remote controller Adapts easily to the installation space. BRC1C61 Note: Remote controller cable not included. Cables must be procured locally. Because air flows out from corner outlets, comfort spreads more widely. Typical flow patterns Navigation Remote Controller (Wired Remote Controller) There are a total of 23 flow patterns. All-round flow 3-way flow (E.g., installed in middle of ceiling) (E.g., installed near a wall) L-shaped 2-way flow Opposite 2-way flow BRC1E62 Note: Remote controller cable not included. Cables must be procured locally. A signal receiver must be added to the indoor unit. Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet. Operation sound increases when using 2-way or 3-way flow. BRC7F633F Grime prevention and bactericidal coating: Make cleaning easier. Signal receiver unit (Installed type) External panels are treated with a coating that Treated Untreated repels dirt. surface surface Wireless remote controller and signal receiver unit are sold as a set. Features *1Applicable when wired remote controller is used *2Applicable when BRC1E62 is used *3Applicable when BRC1C61 is used 3 *4Applicable to RNQ30-48M outdoor units *5Applicable to RNQ13-26M outdoor units *6For the outdoor units Fresh air intake kit • • • • • • • • • • • • • Others Anti corrosion treated heat exchangers Ultra long-life filter High-efficiency filter Options DIII-NET communication standard Interlock control Central remote control External command control *5 Group control by 1 remote controller *4 Control by 2 remote controllers • Auto-restart • Control features Ceiling soiling prevention *3 Filter sign *2 Long-life filter On/Off timer *2 Pre charged for up to 10 m Off timer (programmed) *2 Pre charged for up to 15 m Weekly schedule timer *2 Drain pump mechanism Setpoint range set *1 Work & Servicing Cleanliness Anti-bacterial air filter Setpoint auto reset • • • • • Two selectable temperature-sensors High ceiling application Programme "Dry" Switchable fan speed (2 step) Swing pattern selection Auto swing Remote controller (E.g., installed in a long room) 4-way flow also possible. Wireless LCD remote controller Comfort (E.g., installed in a corner) *6 To prevent dirt sticking to the external panels, they have been coated with a surface treatment. Resists soiling Grimy surface • Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space. Non-flocking flaps Filter has anti-mould and bactericidal treatment Condensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean. Prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters. 4 CEILING MOUNTED CASSETTE TYPE Fine square panels Compact body and quiet operation mm 95 0m Indoor unit High Low 13/18M 21/26M 30/36M 42M 48M 31 35 43 44 44 28 28 32 34 36 Same for all models m Optimal comfort and convenience assured by 2 air discharge modes Note: Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller. Air direction Standard setting Setting to prevent soiling of ceiling* Desired situation Standard position to prevent draft. Recommended for shops with light coloured ceilings that must be kept spotless. Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Quick and easy to install 5-levels air direction setting Auto-swing between 15° and 60° Auto-swing between 25° and 60° Settable to 5 different levels between 25° and 60° Settable to 5 different levels between 15° and 60° The air direction is set automatically to the memorised position of the previous air direction. Auto air direction control *Closing of the corner discharge outlets is recommended. Suitable for high ceilings Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level. Criteria for ceiling height and number of air discharge outlets (Ceiling height is reference value) Number of air discharge outlets used Standard Ceiling High ceiling height High ceiling 13-26M 30-48M All round 4-way 3-way 2-way flow flow flow flow All round 4-way 3-way 2-way flow flow flow flow 2.7 m 3.1 m 3.0 m 3.5 m 3.0 m 3.4 m 3.3 m 3.8 m 3.5 m 4.0 m 3.5 m - 3.2 m 3.4 m 3.6 m 4.2 m 3.6 m 3.9 m 4.0 m 4.2 m 4.2 m 4.5 m 4.2 m - Note: Factory settings are for standard ceiling height and all-round flow. High ceiling settings (1) and (2) are set with the remote controller by field setting. Two selectable temperature-sensors Both indoor unit and wired remote controller (option) contain temperaturesensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians. *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor. Switchable fan speed: High/Low High setting provides maximum reach while low setting minimises drafts. On/Off timer Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses. 5 The condition of the drain pan and drain water can be checked by removing the drain plug and intake grille. 256 mm *1 266 mm *2 Easy height adjustment Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height. Note: If the wireless remote control option is installed, a light receptor unit is housed in one of the adjuster pockets. All models can be installed without using lifter because of the light weight. Installable in any direction Since the orientation of the intake grill can be adjusted after installing, the direction of the intake grill lines can be unified when multiple units are installed. e en th ! p o t e Jus ke grill inta Drain plug With Ultra long-life filters (option), maintenance is not required in normal shops or offices for up to four years. Just 256 mm high. Installable in tight ceiling spaces (13-26M) *1 298 mm high with 30-48M *2 308 mm high with 30-48M Auto-swing Easier to maintain dB(A) Panel size is same for all models, FCNQ13-48M. It is easy to maintain a neat appearance when multiple units are installed. 950 Round Flow Options required for specific operating environments Ultra long-life filter Panel spacer Even in smoky environments where the air conditioning is on most of the time, the ultra long-life filter only has to be changed once a year. Use when only minimal space is available between drop ceilings and ceiling slabs. Smoky atmosphere: annual filter change *For dust concentration of 0.3 mg/m3 (Requires separately sold Air Cleaner.) 1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year 40mm Ordinary store or office: filter change every 4 years Panel spacer *For dust concentration of 0.15 mg/m3 4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 4 years Note: Some ceiling constructions may hinder installation. Contact your Daikin Dealer before installing your unit. High-efficiency filter Available in two types: 65% and 90% colorimetry. Sealing material of air discharge outlet Fresh air intake kit Using this kit, a duct can be fitted to increase the intake of outdoor air. Outside Sealing material block air discharge openings not used in 2-way or 3-way blow. Branch duct (direct-connection round duct) A round duct can be attached without the need for a chamber. Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. **Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking. ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending. A flanged port for direct connection of a round duct is provided. An existing branch duct chamber can also be fitted (square slit hole). The units can be installed in the following different ways. Drain pump is equipped as standard accessory with 850 mm lift. Chamber type (without T-joint pipe and fan) Chamber type (with T-joint pipe and without fan) KDDP55B160 850 mm KDDP55B160K Flexible duct (procured locally) Flexible duct T-joint pipe (procured locally) T-joint pipe Direct installation type KDDP55X160 175 mm Transparent drain socket Because the drain socket is transparent, after the drain piping has been installed, it is easy to check if the drain come out through the socket. Suction chamber Intake duct Connection (procured locally) chamber (duct length: 4 m max.) Suction chamber Intake duct Connection (procured locally) chamber (duct length: 4 m max.) Duct flange (with insulation material) Intake duct (procured locally) Note: Use of options will increase operating sound. Connection to a centralised control system is available without option 6 CEILING SUSPENDED TYPE Diffuses comfortable air throughout the room Upgrade to a quiet and compact system. Quiet operation Sound operation has been reduced on the exposed ceiling suspended type unit. (220V) dB(A) Auto-swing (up&down) brings comfort to the room. Wide air discharge openings produce a spreading 100° airflow FHNQ13/18/21/26/30/36/42/48MV1 Air is blown up to 50° in the downward direction. Indoor unit High Low 13M 43 39 18/21M 44 45 48 49 40 40 42 43 26/30M 36/42M 48M 50° 100° Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Uses quiet stream fan and other quiet technologies. Installable on ceilings 3.5 m high Sound level 44/40dB(A) High Turbulent flow Straightening is reduced plate Quiet stream fan Switchable fan speed: High/Low Low FHNQ21M (220V) Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Wired LCD remote controller Easier to maintain Option Accessory required for indoor unit. Long-life filter lasts about 1 year* * For dust concentration of 0.15 mg/m3 Wired LCD remote controller Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign). Installation flexibility for freedom of design BRC1NU61 Note: Remote controller cable not included. Cables must be procured locally. Non-flocking flap Uniform height and depth. Compact design for small-capacity models to meet tighter dimensional constraints. Wireless LCD remote controller (mm) A signal receiver must be added to the indoor unit. BRC7NU66 Indoor unit 13M 18/21M Height Width Depth 960 1,160 26/30M 36/42/48M 1,400 1,590 Condensation does not easily form on and dirt does not cling to non-flocking flap. It is easy to clean. Non-flocking flap Easy-clean, flat surfaces It is easy to wipe dirt off the flat side and lower surfaces of the unit. 195 680 For all maintenance tasks, access is from bottom surface. Flexible installation Signal receiver unit (Installed type) The unit fits more snugly into tight spaces. Wireless remote controller and signal receiver unit are sold as a set. Features *2 *3 • • 30 mm or more or more *Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case. Others Anti corrosion treated heat exchangers • Auto-restart • Control features Long-life filter *1 Work & Servicing Pre charged for up to 10 m • Anti-bacterial air filter Programme "Dry" • Cleanliness On/Off timer Switchable fan speed (2 step) • High ceiling application Auto swing Remote controller Pre charged for up to 15 m Comfort 30 mm *4 All wiring and internal servicing can be done from under the unit Oil resistant grille Oil-resistant plastic is used for the air suction grille. This satisfies durability in restaurants and other similar environments. Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments. Pipes more easily rigged Plastic cover is used to conceal piping work holes. When piping work the cover is easily taken off, and after piping work easily attached again to conceal the holes. * Installable on max. 3.5 m high ceiling *2Applicable to RNQ30-48M outdoor units *3Applicable to RNQ13-26M outdoor units *4For the outdoor units 1 7 8 DUCT CONNECTION LOW STATIC PRESSURE TYPE DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Ideal for quiet, beautiful living spaces Suitable for condominiums and apartments, houses and hotels Option FDBNQ09/13/18/21/26MV1 Unit can be mounted in the ceiling and air can be delivered freely by duct. Accessory required for indoor unit Option FDMNQ26/30/36/42/48MV1 Wired LCD remote controller Accessory required for indoor unit Wired LCD remote controller BRC1C61 BRC1C61 Navigation Remote Controller Navigation Remote Controller (Wired Remote Controller) (Wired Remote Controller) BRC1E62 Sound level Sound level Wireless LCD remote controller 43/40dB(A) High BRC1E62 BRC4C64 High Low Signal receiver unit (Separate type) FDBNQ26M (220V) Wireless LCD remote controller 45/37dB(A) A signal receiver must be added to the indoor unit. A signal receiver must be added to the indoor unit. BRC4C64 Low Signal receiver unit (Separate type) FDMNQ36M (220V) Wireless remote controller and signal receiver unit are sold as a set. Compact Quiet operation Small, lightweight, and easy-to-install indoor unit. (220V) dB(A) Indoor unit High Low 09/13/18M 41 43 38 40 21/26M Wireless remote controller and signal receiver unit are sold as a set. Freedom of layout The duct system allows the efficient location of discharge outlets in accordance with the room layout To prevent increased operation sound, avoid installing the air suction grille directly below the suction chamber. (Note) Suction chamber Air filter [Duct connection] Low 42 44 45 46 38 36 37 37 42/48M Ordinary duct (procured locally) Note : 270 mm is the minimum size. Extra height is necessary for drain piping slope and insulation. (This feature also applies to duct connection middle static pressure type.) When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms. Door-installed ventilation grille Wall-installed ventilation grille Ordinary duct (procured locally) Air conditioner 305 mm Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening) Drain pipe connection can be done inside the unit. Refrigerant and drain pipe outlets are at the same opening. 325 mm or more (Note) Air discharge Ventilates air through the partitioning wall. (See right) Partitioning wall Ventilation grille Switchable fan speed: High/Low Under-door cutout Ventilation grille Under-door cutout Air intake Note : 325 mm is the minimum size. Extra height is necessary for drain piping slope and insulation. Note: The under-door cutout method should be used only when there is a small volume of airflow. Features * Applicable when wired remote controller is used *2Applicable when BRC1E62 is used *3 *4 *5 • • • Anti corrosion treated heat exchangers *2 Group control by 1 remote controller *2 Others Control by 2 remote controllers *2 Control features Auto-restart *2 Pre charged for up to 10 m *1 Pre charged for up to 15 m • On/Off timer • * Applicable when wired remote controller is used *2Applicable when BRC1E62 is used *3Applicable when BRC1C61 is used 1 Off timer (programmed) *4 Weekly schedule timer • Work & Servicing Setpoint range set • Remote controller Setpoint auto reset • Programme "Dry" *4 Switchable fan speed (2 step) *3 Comfort Anti corrosion treated heat exchangers *2 Group control by 1 remote controller Pre charged for up to 10 m *2 Others Control by 2 remote controllers On/Off timer *2 * Applicable when BRC1C61 is used *4For the outdoor units 3 Control features Auto-restart Off timer (programmed) *2 Weekly schedule timer *1 Work & Servicing Setpoint range set • Setpoint auto reset Programme "Dry" • Remote controller Two selectable temperature-sensors Switchable fan speed (2 step) Comfort Two selectable temperature-sensors Features 9 High 26M 30M Duct connection is simpler with standard rear intake chambers (220V) dB(A) Indoor unit 36M or more 1 Quiet operation *6 * Applicable to RNQ30-48M outdoor units *5Applicable to RNQ26M outdoor units *6For the outdoor units 4 10 OUTDOOR UNIT Simple system provides a diverse assortment of control modes. Control pattern RNQ09MV1 RNQ13MV1 RNQ18MV1 RNQ21MV1 Quiet Operation Fitted with Super Aero Grille RNQ26MV1 RNQ26MY1 RNQ30MV1 RNQ30MY1 RNQ36MV1 RNQ36MY1 RNQ42MY1 RNQ48MY1 Control by 1 remote controller (Basic system) Control by 2 remote controllers For control from 2 locations such as in room and control room, exits, etc. FCNQ Wireless remote controller Non-polar, double-core (max. wiring length 500 m) Signal receiver unit installed on indoor unit Control by 1 wireless remote controller and 1 wired remote controller (See note 2, 3) FDBNQ Signal receiver unit installed on indoor unit Connects 2 wired remote controllers (See note 1) Group control For simultaneous control of up to 16 indoor units. Automatic address setting function Automatic address setting function Signal receiver unit installed on 1 indoor unit Pre charged for up to 15 metres (Applies to RNQ30-48M) If refrigerant piping length does not exceed 10m (RNQ09-26M), 15m (RNQ30-48M), there is no need for on-site gas charging. Control by external command Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. Centralised remote control Centralised control of up to 64 indoor groups from remote location up to 1 kilometer away. Optional wiring adaptor for electrical appendices is necessary Optional wiring adaptor for electrical appendices is necessary Allowed refrigerant piping length and level difference RNQ09/13M RNQ18/21M Pre charged1 Max. level difference Equipped with scroll compressor for quiet operation (Applies to RNQ42-48M) Smooth running, minimal vibration, low operating sound. RNQ26M RNQ30-48M 10 m 10 m 15 m 30 m 30 m Max. length 15 m 50 m (Equivalent length 50m) (Equivalent length 70m) 20 m 30 m Central remote controller (option) The outer panel for the piping connection part of the front, right side and backside can be removed and is easier for post-installation piping work. Separation available Interlock control with Heat Reclaim Ventilator Operation sound Can be operated simultaneously or independently by remote controller (set by ventilation mode) (In case of RNQ09-21M:220-240 V, RNQ26-36M:220 V/380 V, 240 V/415 V, RNQ42-48M:380 V, 415 V) dB(A) Outdoor unit Sound level RNQ09MV1 48 RNQ13MV1 49 RNQ18MV1 51 Heat exchange fins provided with anti-corrosion treatment (Applies to RNQ09-26, 36-48M) To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, Anti corrosion treated heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit. RNQ21MV1 52 RNQ26MV1/RNQ26MY1 54 RNQ30MV1/RNQ30MY1 55 Construction RNQ36MV1/RNQ36MY1 54 Non-treated fin Aluminium RNQ42MY1 56 RNQ48MY1 58 Anti corrosion treated heat exchangers Hydrophilic film Aluminium Corrosion resistant acrylic resin Can be operated simultaneously by remote controller (set by ventilation mode) Central remote controller (option) Zone link control by centralised control. Central remote controller (option) Heat Reclaim Ventilator Heat Reclaim Ventilator Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking Can also be operated independently by remote controller. As the bottom frame is subject to corrosion, corrosion-proof galvarium steel plate is adopted to enhance the durability. Heat Reclaim Ventilator Heat Reclaim Ventilator Link by remote controller group control. 4-direction piping offers greater layout freedom (Applies to RNQ30-48M) Central remote controller (option) FCNQ only Note: 1 Additional refrigerant charging is required if the refrigerant pipe is longer than the length. Durability 11 Wired remote controller FDMNQ Installation and maintenance (Applies to RNQ30-48M) To suppress turbulence and achieve quiet operation, the curved ribs of the grille are optimised to meet the outflow of air. Applicable model Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking Note: 1BRC1E62 can connect to BRC1E62 only. 2 It is not possible to use two wireless remote controllers. 3 BRC1E62 cannot connect to wireless remote controller. Easily adaptable to large-scale, high-function, centralised remote control system. Central remote controller DCS302CA61 (Option) Centralised control, with setting as simple as it is with a standard remote controller, of up to 64 groups (1,024 indoor units) is possible. Unified on/off controller DCS301BA61 (Option) Centralised control of on/off by group or all at once for up to 256 indoor units. FCNQ series only Schedule timer DST301BA61 (Option) Unified control of weekly schedule for up to 1,024 indoor units. Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time. DCS601C51 (Option) With its high functionality, the full colour “all-in-one” graphic controller facilitates management of SkyAir System in a variety of ways. 12 LCD REMOTE CONTROLLER Optional accessory Easy-to-read LCD remote controller allows various system control configurations and can control multiple indoor units. Remote controller options are shown on the page introducing each indoor unit model. Navigation Remote Controller (Wired Remote Controller BRC1E62) Wired LCD remote controller Easy to read because of large LCD screen. The rubber switch and the oil-resistant plastic casing are adopted for durability. This simple, modern designed remote controller with fresh white colour matches your interior design. Operation is much easier and smoother, just follow the indications on the navigation remote controller. NEW Only 17 mm thick. Can be installed either recessed or exposed. Wired remote controller has built-in temperature-sensor (Applies to wired remote controllers (BRC1C61/1E62)) Enables temperature sensing closer to target area for improved comfort. (When using remote control from another room, temperature-sensor in indoor unit's air inlet must be selected.) Facilitates maintenance and repair All initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted cassette type can be remotely set without having to use stepladder access for manual setting. BRC1C61 Setting contents: High ceiling use, air direction, filter type, address Clear Display LCD wireless remote controller Dot matrix display Backlight display A combination of fine dots enables various icons. Large text display is easy to see. The wireless remote controller is supplied in a set with a signal receiver. Signal receiver unit is contained inside decoration panel or indoor unit. Shape of signal receiver unit differs according to the indoor unit. Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the ceiling mounted cassette type. Easily adaptable to large-scale, high-function, centralised remote control systems. Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy. Energy saving Setpoint auto reset NEW - Even if the set temperature is changed, it returns to the preset temperature after apreset period of time. - Period selectable from 30min/60min/90min/120min. Restaurant sample Restaurant opened Temperature is set to 27ºC Full tables at lunchtime Then is lowered to 24ºC for crowded room 27 °C Off timer (programmed) After 30 minutes* Automatically returns to preset temperature (27ºC) Returns to 27 °C 24 °C Setpoint range set - Saves energy by limiting the min. and max. set temperature. - Avoids excessive heating or cooling. - This function is convenient when the remote controller is installed at a place where any number of people may operate it. automatically *Setting possible for after 30, 60, 90, and 120 minutes. Wireless remote controller Signal receiver unit (For ceiling mounted cassette type) Remote controller is equipped with model name and failure display functions. This facilitates service in the unlikely event of a malfunction. (Applies to wired remote controller (BRC1E62)) Ceiling mounted cassette type shares common control with Heat Reclaim Ventilator and the other Daikin air-conditioning units, thus simplifying interlocking operations. BRC7F633F NEW for centralised control (group control address is set automatically). Wireless remote controller for each indoor unit type CEILING MOUNTED CASSETTE TYPE BRC7F633F CEILING SUSPENDED TYPE BRC7NU66 DUCT CONNECTION LOW STATIC PRESSURE TYPE BRC4C64 DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE BRC4C64 LCD panel shows operating status in letters, numbers, and motion. Airflow / swing display - Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts. - Period can be preset from 30 to 180 minutes in10-minute increments. Preset temperature / operation mode display Programming time display Self-diagnosis function Displays auto-swing operating status and setting position of air discharge angle. Displays preset room temperature and operating status (fan, dry, cool). Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning. Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs. Convenience Weekly schedule - 5 actions per day can be scheduled for each day of the week. - The holiday function will disable schedule timer for the days that have been set as holiday. NEW - 3 independent schedules can be set. Multilingual display Display is available in 11 languages. (English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, and Polish). (e.g. summer, winter, mid-season) 13 14 Abundance of functions that provide comfortable air-conditioning in stores and offices. Note: Some features only available on selected models. See model pages for full list of features applicable to each unit. Comfort Auto-swing Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner. High-ceiling application The air flow direction can be fixed at your desited angle by the remote controller. Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings. Note: Some features only available on selected models. See model pages for full list of features applicable to each unit. Work and Servicing Drain pump mechanism Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping. Pre charged for up to 15 metres If refrigerant piping length does not exceed 15 m, there is no need for on-site gas charging. *Applicable to RNQ30-48M. RNQ09-26M : 10 m Filter sign The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit. Ceiling soiling prevention function Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required. Swing pattern selection Long-life filter (standard, ceiling soiling prevention) You can freely set 2 air discharge setting by remote controller. (1) Standard setting Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply. (2) Ceiling soiling prevention setting Two selectable temperature-sensors Switchable fan speed High setting provides maximum reach while low setting minimises drafts. Temperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to target area is possible to further increase the comfort level. Use the temperature-sensor in the indoor unit when controlling air conditioning from another room. Maintenance is not required for one year. The filter is washable and can be reused. Control features Auto-restart If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored. Note: Wireless remote controllers have no temperature-sensor. Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room. Using 2 remote controllers you can operate the equipment locally or from a remote location. Setpoint range set Saves energy by limiting the minimum and maximum set temperatures. Avoids excessive heating and cooling. You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.) Enables interlocking control with external equipment such as Heat Reclaim Ventilator. DIII-NET communication standard Standardly equipped interface enables connection to centralised control system without need of an adaptor. Off timer (programmed) Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts. Options High-efficiency filter unit On/Off timer Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses. Weekly schedule timer Up to five operation ON/OFF settings can be programmed per day for each day of the week. Not only can the time be set for the operation ON setting, but also the temperature. Cleanliness Anti-bacterial air filter The Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it. 15 Optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 kilometer away. Interlock control Remote Controller Even if the set temperature is changed, it returns to the preset temperature after a preset period of time. Central remote control Note: When a wireless remote controller is used, remote control by two remote controllers is not possible. Group control by 1 remote controller Setpoint auto reset Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. *An option is required. Control by 2 remote controllers Programme "Dry" External command control Two types are available: 65% and 90% colorimetry. Ultra long-life filter Requires no maintenance for about 4 years* (10,000h) in stores and offices. *For dust concentration of 0.15 mg/m3 Fresh-air intake kit You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed. Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. **Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking. ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending. Others Anti corrosion treated heat exchangers To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit. In high corrosive areas, regular maintenance needs to be carried out. 16 SPECIFICATIONS CEILING MOUNTED CASSETTE TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity1,2 Cooling1 Sound level (H/L)3 Unit Dimensions (HXWXD) Decoration panel Machine weight Unit Decoration panel Certified Operation range Colour Type Compressor Motor output Refrigerant charge (R-410A) Sound RNQ18MV1 RNQ21MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 --------- --------- --------- --------- --------- RNQ26MY1 RNQ30MY1 RNQ36MY1 RNQ42MY1 RNQ48MY1 3.8 13,000 1.24 3.07 --------5.3 18,000 1.89 2.80 6.2 21,000 2.21 2.80 Certified Operation range Liquid (Flare) Gas (Flare) Drain m3/min cfm dB(A) mm 13/10 459/353 31/28 7.6 26,000 2.53 3.00 mm kg kg kg m Max. installation level difference 44/34 298X840X840 21 24 14 to 23 0.9 1.4 Outdoor unit 14 to 25 Ivory white Hermetically sealed rotary type 1.8 2.2 Hermetically sealed scroll type 3.75 4.5 2.7 49 550X765X285 36 --------- 51 52 595X845X300 40 --------19.4 to 46 o/ 6.4 49 --------- 54 735X825X300 56 56 55 990X940X320 77 74 o/ 12.7 54 103 103 21 to 46 o/ 9.5 56 1,345X900X320 --------107 58 --------111 o/ 15.9 VP25 (I.Do/ 25XO.Do/ 32) o/ 18.0 (Hole) 30 10 15 30 (Equivalent length 50) o/ 26.0 (Hole) 50 (Equivalent length 70) 20 30 Outdoor unit RNQ09MV1 RNQ13MV1 RNQ18MV1 RNQ21MV1 RNQ26MV1 Y1 --------- --------- --------- --------- RNQ26MY1 6.2 21,000 2.38 2.60 3 Phase, 380–415 V, 50 Hz 7.6 26,000 2.62 2.90 dB(A) mm V1 Y1 Certified Operation range Liquid (Flare) Gas (Flare) Indoor unit Drain Outdoor unit Max. interunit piping length kg °CDB mm mm mm mm m 26 FDBNQ26MV1 1 Phase, 220–240 V, 50 Hz --------3.8 13,000 1.28 2.97 2.7 9,200 0.86 3.14 5.2 17,700 2.06 2.52 ---------- 13/11 459/388 18/15 635/530 2.0 41/38 260X900X580 25 43/40 260X1,300X580 32 14 to 23 14 to 25 0.65 0.9 Ivory white Hermetically sealed rotary type 1.4 1.8 2.2 0.9 (Charged for 10 m) 1.2 (Charged for 10 m) 1.4 (Charged for 10 m) 1.5 (Charged for 10 m) 2.0 (Charged for 10 m) 48 49 51 52 54 735X825X300 56 56 21 to 46 o/ 9.5 550X765X285 35 ---------- 595X845X300 36 ---------- 40 ---------- 49 ---------- 19.4 to 46 o/ 6.4 o/ 12.7 3/4B (I.Do/ 21.6XO.Do/ 27.2) o/ 18.0 (Hole) o/ 9.5 o/ 15.9 30 (Equivalent length 50 m) 30 m 10 15 Both liquid and gas piping 20 Cooling1 Colour Airflow rate (H/L) Type Motor output Piping connections Liquid (Flare) Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation RNQ21MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 --------- --------- --------- --------- RNQ26MY1 RNQ30MY1 RNQ36MY1 RNQ42MY1 RNQ48MY1 3.8 13,000 1.58 2.40 --------5.3 18,000 2.04 2.60 kg Sound level3 Certified operation range RNQ18MV1 --------- kW Refrigerant charge (R-410A) Dimensions (HXWXD) Machine weight RNQ13MV1 Y1 m3/min cfm dB(A) mm kg °CWB Sound level (H/L) (220 V)3 Colour Compressor DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE V1 V1 Y1 kW Btu/h kW W/W Outdoor unit Dimensions (HXWXD) Machine weight Certified operation range V1 Y1 dB(A) mm kg kg °CDB mm mm mm mm 16/565/43/39 195X960X680 24 0.9 6.2 21,000 2.38 2.60 22-23/19-20 777-812/671-706 44/40 195X1,160X680 26 14 to 23 7.6 26,000 2.65 3 Phase, 380–415 V, 50 Hz 8.8 10.4 12.3 30,000 35,000 42,000 4.51 3.07 3.64 2.73 2.86 2.87 White 26-27/22-23 918-953/777-812 45/40 195X1,400X680 32 42-44/24-26 38-40/23-25 1,341-1,412/812-883 1,483-1,553/847-918 48/42 49/43 195X1,590X680 35 14 to 25 Ivory white Hermetically sealed rotary type 1.8 2.2 1.4 Hermetically sealed scroll type 3.75 4.5 2.7 51 49 550X765X285 36 --------- 52 595X845X300 40 --------19.4 to 46 o/ 6.4 49 --------- 54 54 55 735X825X300 990X940X320 56 56 77 74 o/ 12.7 56 Power consumption COP Colour Indoor unit Outdoor unit --------107 VP20 (I.Do/ 20XO.Do/ 26) 30 (Equivalent length 50) 30 10 15 20 Both liquid and gas piping --------111 Certified Operation range Liquid (Flare) Gas (Flare) Indoor unit Drain Outdoor unit Max. interunit piping length o/ 26.0 (Hole) 50 (Equivalent length 70) RNQ30MV1 RNQ36MV1 --------- --------- RNQ30MY1 RNQ36MY1 RNQ42MY1 RNQ48MY1 kg °CDB mm mm mm mm m 30 Max. installation level difference Heat insulation 48 FDMNQ48MV1 RNQ26MV1 dB(A) mm V1 Y1 42 FDMNQ42MV1 RNQ26MY1 Rated external static pressure3 mmH2O Sound level (H/L) (220 V)4 dB(A) mm Dimensions (HXWXD) kg Machine weight Certified Operation range °CWB Colour Type Compressor Motor output kW Refrigerant charge kg (R-410A) Sound level4 Dimensions (HXWXD) Machine weight 36 FDMNQ36MV1 Y1 m3/min cfm Airflow rate (H)3 Piping connections o/ 15.9 o/ 18.0 (Hole) 58 Fan Cooling1 30 FDMNQ30MV1 V1 V1 Y1 kW Btu/h kW W/W Outdoor unit Cooling capacity1,2 1,345X900X320 103 103 21 to 46 o/ 9.5 Outdoor unit Power supply 14.1 48,000 5.51 2.56 26 FDMNQ26MV1 Indoor unit Model Name 1.2 1.4 1.5 2.0 1.9 3.2 2.7 3.2 (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) m m --------- 1 Phase, 220–240 V, 50 Hz Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Capacities are net, including a deduction for cooling for indoor fan motor heat. 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 17 V1 Rated external static pressure3 mmH2O Sound level (H/L) (220 V)4 dB(A) mm Dimensions (HXWXD) kg Machine weight Certified Operation range °CWB Colour Type Compressor Motor output kW Refrigerant charge kg (R-410A) Piping connections 26 30 36 42 48 13 18 21 FHNQ13MV1 FHNQ18MV1 FHNQ21MV1 FHNQ26MV1 FHNQ30MV1 FHNQ36MV1 FHNQ42MV1 FHNQ48MV1 Indoor unit Power consumption COP Outdoor unit 21 FDBNQ21MV1 Both liquid and gas piping Cooling capacity1,2 Indoor unit 18 FDBNQ18MV1 m3/min cfm Airflow rate (H/L)3 Max. installation level difference Heat insulation CEILING SUSPENDED TYPE Power supply Cooling1 Sound level4 Dimensions (HXWXD) Machine weight 1.2 1.4 1.5 2.0 1.9 3.2 2.7 3.2 (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m) Heat insulation Model Name Fan 44/36 5.5 mm mm m Max. interunit piping length Power consumption COP Colour Indoor 33/22.5 1,165/794 13 FDBNQ13MV1 V1 Y1 kW Btu/h kW W/W Outdoor unit Cooling capacity1,2 50X950X950 19.5 °CWB kW 32/20 1,130/706 43/32 Outdoor unit Power supply 14.1 48,000 5.04 2.80 09 FDBNQ09MV1 Indoor unit Model Name unit 21/13.5 741/477 35/28 256X840X840 °CDB mm mm Indoor unit Outdoor unit 3 Phase, 380–415 V, 50 Hz 8.8 10.6 12.5 30,000 36,000 42,600 4.15 2.73 3.31 3.01 3.22 3.20 ---------- dB(A) mm V1 Y1 --------- 1 Phase, 220–240 V, 50 Hz Fresh white kg level3 Dimensions (HXWXD) Machine weight Piping connections RNQ13MV1 Y1 Unit Decoration panel Airflow rate (H/L) Outdoor unit V1 V1 Y1 kW Btu/h kW W/W Outdoor unit Power consumption COP Indoor Colour unit DUCT CONNECTION LOW STATIC PRESSURE TYPE 13 18 21 26 30 36 42 48 FCNQ13MV1 FCNQ18MV1 FCNQ21MV1 FCNQ26MV1 FCNQ30MV1 FCNQ36MV1 FCNQ42MV1 FCNQ48MV1 m 7.6 26,000 2.62 2.90 23 812 8.5 42/38 305X1,350X680 43 --------1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz 8.8 10.6 12.3 14.1 30,000 36,000 42,000 48,000 3.53 4.49 5.56 3.03 3.00 2.74 2.54 2.90 ---------42 37 1,306 1,483 9.8 8.0 44/36 45/37 46/37 305X1,550X680 52 14 to 25 Ivory white Hermetically sealed rotary type Hermetically sealed scroll type 2.2 2.7 3.75 4.5 2.0 (Charged for 10 m) 1.9 (Charged for 15 m) 3.2 (Charged for 15 m) 2.7 (Charged for 15 m) 3.2 (Charged for 15 m) 54 735X825X300 56 56 55 990X940X320 77 74 54 56 1,345X900X320 ---------107 58 o/ 18.0 (Hole) 30 (Equivalent length 50 m) 20 103 103 21 to 46 o/ 9.5 o/ 15.9 3/4B (I.Do/ 21.6XO.Do/ 27.2) o/ 26.0 (Hole) 50 (Equivalent length 70 m) ---------111 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Capacities are net, including a deduction for cooling for indoor fan motor heat. 3 Please see fan characteristic document in detail. 4 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 18 OPTIONS Indoor unit Indoor unit CEILING MOUNTED CASSETTE TYPE Name of option CEILING SUSPENDED TYPE Remark Decoration panel Sealing material of air discharge outlet Panel spacer Fresh air Chamber type intake kit1 Without T-joint pipe and fan With T-joint pipe, without fan Direct installation type Chamber connection kit2 Insulation kit for high humidity (Colorimetric method 65%) High-efficiency filter (including chamber) (Colorimetric method 90%) Replacement (Colorimetric method 65%) high-efficiency filter (Colorimetric method 90%) Filter chamber Replacement long-life filter Ultra long-life filter Replacement ultra long-life filter Branch duct chamber Wireless type Cooling only Remote controller Wired type3 Navigation Remote Controller Wired type3 Central remote controller4 Unified ON/OFF controller4 Schedule timer4 Touch Controller4 Adaptor for wiring5 Wiring adaptor for electrical appendices5 Installation box for adaptor PCB Remote sensor Kit name FCNQ13MV1 FCNQ18MV1 FCNQ21MV1 FCNQ26MV1 FCNQ30MV1 FCNQ36MV1 FCNQ42MV1 FCNQ48MV1 BYCP125K-W1 KDBH55K160F KDBP55H160FA KDDP55B160 KDDP55B160K KDDP55X160 KKSJ55KA160 KDTP55K160 KDTP55K80 KAFP556B160 KAFP556B80 KAFP557B160 KAFP557B80 KAFP552B160 KAFP552B80 KAFP553B160 KAFP553B80 KDDFP55B160 KAFP551K160 KAFP55B160 KAFP55H160H KDJP55B80 KDJP55B160 BRC7F633F BRC1C61 BRC1E62 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP1C63 KRP4AA53 KRP1H98 KRCS01-4B Note: 1Refer to page 6 for the details. 2 Required for installing high-efficiency filter or ultra long-life filter. 3 Wiring for wired remote controller to be procured locally. 4 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 5 Installation box for adaptor PCB (KRP1H98) is necessary. For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option (shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect. A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation. Panel spacer Operation control related Wireless remote controller Auxillary function related Fresh air intake kit (Chamber type)1,2 Fresh air intake kit (direct mount) High-humidity operation kit Filter related Panel spacer1 High-efficiency filter2 Ultra-long-life filter2 Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o 1 Panel/grille related Replacement long-life filter L-type piping kit (for upward direction) Remote controller o o o x o o o o o o o Resin net Wireless type Wired type1 Kit name FHNQ13MV1 FHNQ18MV1 FHNQ21MV1 FHNQ26MV1 FHNQ30MV1 FHNQ36MV1 FHNQ42MV1 FHNQ48MV1 KAF501DA80 KAF501DA112 KAF501DA160 KAF501DA56 KHFJ5F60 KHFP5MA160 KHFJ5F50 BRC7NU66 BRC1NU61 Note: 1Wiring for wired remote controller to be procured locally. DUCT CONNECTION LOW STATIC PRESSURE TYPE Name of option Remote controller Navigation Remote Controller Remark FDBNQ09MV1 FDBNQ13MV1 Wireless type Wired type1 Wired type1 Kit name FDBNQ18MV1 BRC4C64 BRC1C61 BRC1E62 FDBNQ21MV1 FDBNQ26MV1 FDMNQ42MV1 FDMNQ48MV1 Note: 1Wiring for wired remote controller to be procured locally. DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE Name of option Remote controller Navigation Remote Controller Remark Wireless type Wired type1 Wired type1 FDMNQ26MV1 FDMNQ30MV1 Kit name FDMNQ36MV1 BRC4C64 BRC1C61 BRC1E62 Outdoor unit Name of option Central drain plug All round flow 4-way flow Optional accessory parts Remark Note: 1Wiring for wired remote controller to be procured locally. Round flow type: List of optional parts required to achieve different flow patterns Independently installable optional parts Name of option o o x x o o o o x o o o High-humidity operation kit High-efficiency filter2 Ultra-long-life filter2 x o x o o o o o x o o o o x x x x x High-humidity operation kit High-efficiency filter2 x o x o x x x x x x x High-humidity operation kit High-efficiency filter2 Ultra-long-life filter2 x x x x x x o o o Kit name ------------RNQ09MV1 RNQ13MV1 RNQ18MV1 RNQ21MV1 RNQ26MV1 RNQ30MV1 RNQ36MV1 ------------------------RNQ26MY1 RNQ30MY1 RNQ36MY1 RNQ42MY1 RNQ48MY1 ------------KKP014A4 KKPJ5F180 3-way flow 2-way flow Optional accessory parts Independently installable optional parts Panel/grille related Panel spacer1 Operation control related Wireless remote controller Auxillary function related Fresh air intake kit (Chamber type)1,2 Fresh air intake kit (direct mount) High-humidity operation kit Filter related Ultra-long-life filter2 Panel spacer1 Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o3 o3 o3 o3 x o3 o o o o o3 o x x o o3 o x o o Ultra-long-life filter2 o3 o o o x Branch duct connection Optional accessory parts Independently installable optional parts duct1 Branch (Chamber type) (Round duct type) 1-way branch / unit 3-way flow 2-way branch / unit 2-way flow 1-way branch / unit 2-way flow Panel spacer1 o x x Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o o o o o o o o o 4 4 4 1 In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable. 2 Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position. 3 It is not possible to use panel spacers in a 2-way flow installation. 4 It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed. 19 20 DIMENSIONS (Unit: mm) CEILING MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPE 157 350 A 157 350 2x100=200 25 213 213 C/L 90 183 C arrow view Connection position of branch duct (round shape type) Connection position of fresh air intake kit (direct installation type) 90 80 ø10 (kn 0 ock hole ) 90 196 ø10 (kn 0 ock hole ) Hanging bolt 4-M8~M10 1 5 55 13 6 4 B 30 or more (Service space) (Service space) Drain pipe connection VP20 (For left piping) 6 80 A 35 or less (Note 4) Connection position of branch duct (square-shaped type) Notes: 1 Sticking location for manufacture's label manufacture's label for indoor unit: Suction grille inner side's electric components box's lid surface manufacture's label for decoration panel : Decoration panel's corner decoration cover inner surface 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3 When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required. 4 Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured. 5 Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 7 5 105 4 Notes: 1 Location of unit's Name plate : Bottom of fan housing inside the suction grille. 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3 The remote control code is the standard <about 3m outside the machine> attached. (0.5mm2x2 wicks O.D. 5.4)(It is not attached to VRV.) 115 60 65 DUCT CONNECTION LOW STATIC PRESSURE TYPE [FDBNQ09/13/18MV1] 1 2 3 4 5 6 7 8 9 Liquid pipe connection Gas pipe connection Drain pipe connection Power-source wiring and a unit wiring connection Connection wiring/remote control wiring connection Air-outlet Suction grille Corner decoration cover Drain hose (accessory) 900 704 151 3 3 8 300 or more Service space 500 10-M4 Holes (All Around) 1 2 3 4 2 4 Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal 29 1 260 6 7 12-M4 Holes (All Around) 5 6 7 8 150 219 236 5 110 170 228 684 664 3×P150=450 134 107 164 260 50 126 755 (Suspension bolt pinch) 21 Air discharge grille Air suction grille Air filter Gas pipe connection Liquid pipe connection Drain pipe connection Earth terminal (Inside the electric components box) Suspension bracket Backward pipe and wiring connection opening lid Upward pipe and wiring connection opening lid Right side pipe connection Left back drain pipe connection Left side drain pipe connection Right side drain pipe connection Hole of wall for taking out in pipe back Upward drain pipe connection Upward gas pipe connection Upward liquid pipe connection 10 or more 157 350 200mm or more 1500mm or more The necessary space is 500mm or more when the air-outlet is blocked with the accessory. Moreover when the corner areas are blocked (both right and left of the blocked air outlet), the necessary space is 200mm or more. 14 271 130 95 167 93 29 60 42 256 1500mm or more 1500mm or more 2 170 167 2 5 3 1500mm or more 500 (Suspension bolt pinch) 137 1 27-M4 Prepared hole 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 C arrow view 55 4 35 or less (Note 4) Connection position of branch duct (round shape type) 55 55 Brand name plate (Note.2) 580 280 330 840 81 2x100=200 85 160 64 50 o/ 45 The Front Obstacle Floor side 317 157 105 160 298 125 165 20 C/L 350 3 1500 or more 67 (required space) 160 From the floor side 2500 or more For height installation Hanging bolt 4-M8~M10 Connection position of branch duct (round shape type) 55 Connection position of branch duct (square-shaped type) 150 55 95 167 840 340 80 2x100=200 80 160 175 29 55 50 40 160 288 10 850 Adjustable(0~675) 16-M4 Prepared hole Position : Hole of wall for taking out in piping back (View from the front) 80 90 155 30 or more [FCNQ30-48MV1] Required space 200mm or more 11 40 680 80 [FCNQ30-48MV1] 105 15 A (Hanging position) 5 (Required space) 67 95 29 157 350 2x100=200 80 25 160 80 124 35 or less (Note 4) Connection position of branch duct (square-shaped type) Connection position of branch duct (round shape type) Connection position of fresh air intake kit (direct installation type) 90 256 C/L 80 95 110 124 60 130 150 20-M4 Prepared hole 5 160 65 Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket 16 10 151 127 3×P.150=450 674 688 704 900 52 16 10 280 330 55 167 93 145 60 Position slit hole for taking out in piping back (View from the front) 10 225 275 2 840 81 2x100=200 85 124 64 50 42 105 3 127 60 8 Connection position of branch duct (square-shaped type) 20-M4 Prepared hole 9 5 135 (Required space) 1550 1590 40 135 FHNQ48MV1 50 195 B arrow view 36 1550 1590 185 1550 1590 FHNQ42MV1 192 FHNQ36MV1 Connection position of branch duct (square-shaped type) 167 157 350 102 1360 1400 160 1360 1400 FHNQ30MV1 12 85 1120 1160 FHNQ26MV1 210 1120 1160 FHNQ21MV1 260 FHNQ18MV1 16-M4 Hole (Hanging position) 960 170 105 90 58 18 17 16 142 300 275 1 55 35 or less (Note 4) Connection position of branch duct (round shape type) 157 4 920 [FCNQ30-48MV1] 160 124 109 95 Connection position of branch duct (square-shaped type) 20-M4 Prepared hole 1500 or more (required space) 160 From the floor side 2500 or more For height installation 350 FHNQ13MV1 For height installation [FCNQ13-26MV1] [FCNQ13-26MV1] 125 165 256 50 40 20 C/L Hanging bolt 4-M8~M10 Connection position of branch duct (round shape type) 2x100=200 160 C/L 160 67 7 95 110 124 340 80 2x100=200 80 124 B Drain Connection Side 16-M4 Prepared hole 55 Connection position of branch duct (square-shaped type) 175 850 Adjustable(0~675) B arrow view 6 Connection position of branch duct (square-shaped type) A arrow view 840 A Connection position 85 of branch duct (round shape type) 93 160 124 C 81 16-M4 Hole 157 350 950 780(Hanging bolt pitch) 860~910(Ceiling opening space) (Note 4) Pipe Connection Side [FCNQ13-26MV1] 160 246 10 Note 2 8 420 55 2x100=200 124 C/L 81 950 Connection position 85 of branch duct (round shape type) 95 110 860~910(Ceiling opening space) (Note 4) 300 or less 710(Hanging bolt pitch) 420 9 [FHNQ13/18/21/26/30/36/42/48MV1] [FCNQ30-48MV1] 300 or more (Required space) [FCNQ13-26MV1] From the floor side 2500 or more 155 [FCNQ13-48MV1] B 29 95 [FCNQ13-48MV1] Note: 1Location of unit's Name Plate: Chamber cap 22 DIMENSIONS (Unit: mm) DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE DUCT CONNECTION LOW STATIC PRESSURE TYPE [FDBNQ21/26MV1] [FDMNQ30/36/42/48MV1] 1550 300 or more 5 6 7 8 Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket Note: 1Location of unit's Name Plate: Chamber cap DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE 381 263 280 10 7 150 305 6 1 74 5 16 29 4 274 152 827 18-M4 Holes (All Around) 1 2 3 4 51 2 212 50 18-M4 Holes (All Around) Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal 7×P150=1050 123 206 175 305 219 236 7 10 260 228 6 1 150 29 1550 1353 1337 1321 7×P150=1050 151 8 16 1334 1314 52 700 16-M4 Holes (All Around) 170 110 50 107 260 164 134 102 1088 1074 6×P.150=900 4 5 126 1403 (Suspension bolt pinch) 1300 1104 10 16 2 Service space 55 8 151 1084 1064 6×P150=900 146 Service space 126 1155 (Suspension bolt pinch) 16 8 1 2 3 4 600 (Suspension bolt pinch) 116 427 680 3 55 317 580 3 3 271 500 (Suspension bolt pinch) 137 3 300 or more 151 1353 10 or more 151 167 1300 1104 20-M4 Holes (All Around) 5 6 7 8 Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket Note: 1Location of unit's Name Plate: Chamber cap OUTDOOR UNIT // RNQ09/13MV1 [FDMNQ26MV1] 4-Hole for anchor bolts (M8 or M10) Drain outlet (I.D. 15.9 hose for connection) 574 311 381 146 Handle 285 51 2 196 In case of removing stop valve cover 29 1 6 74 16 10 727 Wall height on air outlet side =less than 1200 7 22 Gas stop valve ( 15.9CuT for RNQ13) ( 9.5CuT for RNQ09) 150 5 165 550 Wiring inlet 4 152 212 274 305 206 175 123 50 50 50 50 100 Switch box Control wiring intake (for remote controller) Control wiring intake (for outdoor unit) Suspension bracket 300 5 6 7 8 150 20-M4 Holes (All Around) 100 23 Liquid pipe connection Gas pipe connection Drain pipe connection Ground terminal Liquid stop valve ( 6.4CuT) Service port 305 7×P150=1050 1350 1153 1137 1121 7×P150=1050 Minimum space for air passage 1 2 3 4 Manufacture’s label 105 151 8 16 1134 1114 18-M4 Holes (All Around) Brand name label 63 126 1203 (Suspension bolt pinch) 50 765 150 263 280 8 12 8 Service space 55 427 680 3 116 600 (Suspension bolt pinch) 3 105.5 490 13 300 or more 151 29.5 1350 1153 Note: 1Location of unit's Name Plate: Chamber cap 24 DIMENSIONS (Unit: mm) OUTDOOR UNIT // RNQ18/21MV1 OUTDOOR UNIT // RNQ30MV1, RNQ30MY1 30 Hole for anchor bolt 4-M12 573.5 320 91 160 4-Hole for anchor bolts (M8 or M10) 20 7 30 38 300 326 342 131 55 78 300 37 845 350 (345∼355) Drain outlet I.D. 18 hose for connection 620 30 Name plate Brand name label 160 940 Earth terminal in switch box Wiring inlet 4 3 7 60 1 5 6 19 55 223 80 145 13 68 300 285 279 260 161 150 50 1 Gas pipe connection 2 Liquid pipe connection 50 3 Service port 4 Grounding terminal 36 61 300 50 5 Refrigerant piping intake 6 Power supply wiring intake 262 416 595 OUTDOOR UNIT // RNQ26MV1, RNQ26MY1 30 Hole for anchor bolt 4-M12 96 140 620 140 900 30 25 10 30 300 330 350 41 320 580 2 48 350 325 61 78 (345~355) 825 36 7 Control wiring intake 8 Drain pipe connection OUTDOOR UNIT // RNQ36MV1, RNQ36/42/48MY1 Drain outlet I.D. 15.9 hose for connection 124 67 16 5 50 52 16 8 300 100 90 53 84 19 142 Wall height on air outlet side =less than 1000 5 55 340 53 89 53 Gas stop valve ( 15.9CuT for RNQ21MV1) ( 12.7CuT for RNQ18MV1) 7 Minimum space for air passage 6 95 95 339 60 20 144 89 Service port 6 5 105 Liquid stop valve ( 6.4CuT) 7 95 990 595 2 4-Hole for anchor bolts (M8 or M10) 4 Brand name label Name plate Earth terminal in switch box Wiring inlet 2 1 3 55 5 54 80 95 223 84 95 55 435 19 145 16 58 70 102 117 350 16 5 45 25 6 52 13 67 8 100 50 350 100 350 50 19 142 71 50 7 6 410 95 89 54 89 Wall height on air outlet side =less than 1200 Gas stop valve ( 15.9CuT) 100 Minimum space for air passage 18 30 24 Service port 155 160 7 5 5 60 Liquid stop valve ( 9.5CuT) 6 53 89 64 1345 735 7 376 191 1 2 3 4 5 6 7 8 Gas pipe connection Liquid pipe connection Service port (in the unit) Grounding terminal Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection 26 DIMENSIONS Installation service space for outdoor unit (Unit: mm) For RNQ30-48MV1/Y1 REMOTE CONTROLLER Wireless type (Unit: mm) Remote controller dimensions 1 When there is an obstruction on the inlet side BRC7F633F BRC4C64 2 When there is an obstruction on the outlet side CEILING MOUNTED CASSETTE TYPE <Round Flow> • Receiver installation procedure Remote controller holder installation procedure <Installation to wall surface> Transmitting part • Receiver detail 1) When the overhead space is open 1) When the overhead space is open Receiver Refrigerant piping side 157 1. For single unit installation Liquid crystal remote controller (Wireless) When there is an obstruction only on the inlet side Decoration panel Drain piping side 1. For single unit installation 50 Remote controller holder 0 10 CEILING SUSPENDED TYPE 62 17.5 Receiver installation procedure The Front Receiver detail mo or re 2. For multiple units installation (more than two units) rm ore 10 0 mo or re 10 0 mo or re When there are obstructions on both sides Receiver 0o BRC7NU66 100 or m ore 100 or m Remote controller (Wireless) 2-5x9 Slot 70 0.5 35 18 More than 90 (Srevice space) 18.1 (Ceiling opening) 120 54 Note : Do not install more than 3 receivers in the vicinity of one another. With 4 or more units, there is always the possibility of malfunction 49 (Ceiling opening) 10 00 re 20 0o rm 30 0o r re mo 0 50 2. For multiple units installation (more than two units) 50 2) When there is an obstruction in the overhead space or 0o mo r le re ss Conduit 42 117 84 120 38 When there is an obstruction on the inlet side 0~5 Through hole Cord outlet hole 17 CONTROL BOX Note) 1. Remote controller cord and staple are not attached. they are field supplied parts. (fl12~fl16) ( Distance between remote controller and control box ) Specifications of cord Type Vinyl cord with sheath or cable (Insulated thickness: 1 mm or more) Size 0.75~1.25 mm2 Total length 500 m * Countries requiring EMC: Shield wire (insulated thickness: 1 mm or more) BRC1E62 • Installation method Lower case A Exposed cord Top left outlet B Embedded cord Staple Condit C Embedded cord (use switch box) 19 19 42 Top center outlet Operation lamp (Green) 10 When there are obstructions on the inlet side and both sides 84 84 40 0 or s les 50 150 or m 0o 1 An obstruction in the overhead space 84 50 An obstruction in the overhead space 10 0o r le 0o rm or ss 0 00 or re mo e 3 When there are obstructions on both the inlet and outlet sides (When the obstruction on the outlet side is higher than the unit itself) 1) When the overhead space is open (There is no limit to the height of the obstruction on the outlet side.) ore 150 e or rm ore 40 1. For single unit installation o 50 or m 1 48.5 Left outlet 19 Lower case portion Note)2 28 Through hole Switch box for one switch ( 8- 10) ex.) KJB111A (optional accessory) Lower case Note) 1. Remote controller cord and staple are not attached. They are field supplied parts. Specifications of cord BRC1NU61 6 44.5 20 Note) The dimension of hole. 25 Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more) Size 0.75~1.25 mm2 Total length 500 m 46 0~5 Switch box for two switch (Between remote ex.) KJB211A controller and (optional accessory) control box) Switch box portion [field supplied part] 2.If the hole size is too large or the location is not proper, the hole may come out from the remote controller. 2. For multiple units installation (more than two units) When there are obstructions on the inlet side and both sides An obstruction in the overhead space 10 10 0 mo or re 50 0o r le ss 10 00 or mo L H 2. For multiple units installation (more than two units) 0o 0 50 ore m or 10 0 mo or re 10 0 mo or re rm ore re 24 10 25 20 41 a 38 41.5 A A 20 0o 4 R2 rm ore 77 B A 111 B 17 13 119 22 25 A B Hole type A B 0 10 ore m or H 5X15 oblong hole L 28 23 48.5 46 1000 or more 19 L Code outlet hole 5X7 oblong hole rm ore 1. For single unit installation 17 18 23 28 46 An obstruction in the overhead space H 17 Staple C Exposed body, embedded code 1000 or more B Exposed body, embedded cord 1000 or more A EXposed body, exposed cord 120 ss mo ore Remote controller installation procedure Upper case r le 10 0 mo or re BRC1C61 17 0o ore 1. For single unit installation Remote controller dimensions 120 50 rm An obstruction in the overhead space or (field Supplied parts) 120 2) When there is an obstruction in the overhead space 10 0 mo or re 10 0 mo or re When there are obstructions on both sides Switch box Wired type rm 2. For multiple units installation (more than two units) Service space for ceiling installation 72 83.5 106 Remote controller holder 0o 0o 1000 or more 115.5 Receiver detail 10 ore 0 10 ore 1000 or more Remote controller holder installation procedure <Installation to wall surface> Transmitting part 0 30 or mo re L H 00 10 ore m or 0 30 ore m or a (mm) 6 10 Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book. 27 28 MEMO 29 30