Download VAT2000

Transcript
Micro variable speed drives
VAT2000
T2000
Auto-tuning
Soft Sound
The VAT2000 is performed with an Auto-tuning function which simplifies the adjustment of critical control parameters. The Automatic
tuning can be performed in four mode of operation, V/f Constant
Torque, V/f Variable Torque, Vector Sensorless, Full Vector with
sensor.
VAT2000 Soft Sound technology reduces the characteristic whine
from inverter-driven motors and eliminates the side-effects of conventional noise reduction methods, specifically that of raising the
carrier frequency.
Soft Sound varies the carrier frequency in one of two fixed patterns,
from a user-selected base frequency (between 2.1kHz and 5kHz). By
keeping the carrier frequency range low, torque performance is
notably better tha a high-frequency carrier.
The high frequency induced problems of hot running, degrading of
winding insularion, arcing across motor bearings, high leakage
currents, interference,.... These are decreased by using Soft Sound
carrier frequency.
Auto-tuning procedure
Input inverter and motor ratings
Select the drive mode
Soft Sound
Run the drive
(run the tuning)
Auto-tuning error
Auto
tuning
OK
Error
displayed
V/f or Vector related parameters are
automatically set
Auto-tuning is complete
Drive and motor ratings
B00/1-0
B00/1-1
B00/1-2
B00/1-4
B00/1-5
B00/1-6
B00/1-7
B01-8
Input voltage (V)
Motor rated output voltage (kW)
Number of motor poles (Pole)
Max. speed (min-1)
Base speed (min-1)
Motor rated current (A)
Carrier frequency
Number of encoder pulses (P/R)
Drive mode
C30-0 = 1
C30-0 = 2
C30-0 = 3
C30-0 = 4
C30-0 = 5
V/f Constant torque
V/f Variable torque
Vector sensorless
Full vector
PM motor control
J
J.18
GE Power Controls