Download ET 6, 9, AND 14 QUICK PROGRAMMING GUIDE

Transcript
ET 6, 9 and 14 Quick Programming Guide
Accumulation Explanation:
The Accumulation feature, shown in the Settings display, is used to prevent short irrigation
run times. In the winter and at other times that the ET value is low the controller may
calculate a runtime that is very short. If the Accumulation feature is ON, the controller will
save the short run times and wait unit it has accumulated enough run time to turn the
irrigation valve on for at least 50% of the programmed minutes. The controller will skip days
until it has accumulated enough minutes to turn on the irrigation valve.
Troubleshooting Guide
Problem
Causes
Solutions
Display is blank.
Display shows
“Fuse/Power Fault”
Blown fuse.
No power to controller.
Replace fuse.
Check outlet / breaker.
Check transformer / wiring.
Display shows
“Fuse/Power Fault”
“Check Station”
Irrigation Valve defective.
Short in valve wiring.
More then two valves connected.
Check irrigation valve.
Check wiring.
Reduce number of valves
connected to station.
Did not Irrigate
Day is not programmed.
Rain Delay (display has D1).
Controller skipping days.
Check programming.
A rain delay is in process.
In the winter or on cooler days the
unit will skip days.
Ran less then programmed
minutes.
Ran more then programmed
minutes
Normal operation
The controller will adjust the
number of minutes based on
historical data and the present
weather conditions.
Page 6