Download Manual - ToppTopo A/S

Transcript
7 DATA COLLECTION
7.2 Operational Procedure of “DATA COLLECT”
Operating procedure
Operation
Display
DATA COLLECT
1/2
F1:OCC.PT# INPUT
F2:BACKSIGHT
F3:FS/SS
P↓
1 Press the [F3](FS/SS) key from the data collect
[F3]
menu 1/2.
The previous data is shown.
2 Press the [F1](INPUT) key and enter PT#.
[F1]
Enter PT#
[F4]
Press the [F4](ENT) key. *1)
PT#
PCODE
R.HT
INPUT
PT#
=PT-01
PCODE :
R.HT :
0.000 m
[ALP][SPC][CLR][ENT]
PT#
PCODE
R.HT
INPUT
3 Enter PCODE, R.HT in the same way. *2),3)
[F1]
Enter
PCODE
[F4]
[F1]
EnterR.HT
[F4]
[F3]
4 Press the [F3](MEAS) key.
5 Collimate the target point.
→
:
:
0.000 m
SRCH MEAS ALL
:PT-01
→
:
0.000 m
SRCH MEAS ALL
→ PT-01
PT#
PCODE :TOPCON
R.HT :
1.200 m
INPUT SRCH MEAS ALL
VH *SD
NEZ OFSET
Collimate
6 Press one of the [F1] to [F3] key. *4)
[F2]
Example: [F2](SD) key.
Measuring starts.
The measuring data is memorized and the display
changes to the next point. *5)
PT# is automatically incremented.
7 Enter the next point data and collimate the next
V : 90°10'20"
HR: 120°30'40"
SD*[n]
< m
> Measuring...
< complete >
PT#
PCODE
R.HT
INPUT
→ PT-02
:TOPCON
:
1.200 m
SRCH MEAS ALL
Collimate
point.
8 Press [F4](ALL) key.
Measuring starts in the same measuring mode of
the previous point.
Data is recorded.
[F4]
V : 90°10'20"
HR: 120°30'40"
SD*[n]
< m
> Measuring...
< complete >
PT#
PCODE
R.HT
INPUT
Continue the measuring in the same way.
To finish the mode , press [ESC] key.
7-7
→ PT-03
:TOPCON
:
1.200 m
SRCH MEAS ALL