Download FC3600 - Graphtec

Transcript
3.9
Setting Cutting Conditions in THICK Mode
When THICK mode is specified in the conditions, the overcutting settings must be completed. For details
on THICK mode settings, see section 4.14 “Specifying THICK Mode Settings.
CHECKPOINT
THICK mode is normally activated when T1 or T2 is selected as the tool.
Mode Selection
Two modes are available for overcutting; choose the mode best suited for your application.
(Default value: Mode 1)
Mode 1 : Perform overcutting for the cutting start and end points and for corners with acute angles to prevent uncut areas. Compared with Mode 2, this supports finer cutting and cutting of thicker media.
Mode 2 : Perform overcutting only for the cutting start and end points. Compared with Mode 1, this supports faster cutting, since less control is required for intermediary cutting.
1.
Press a function key from F1 to F4 to select the COND No. for THICK mode. Next, press the
CONDITIONS key to display the conditions.
2.
After entering each condition value, press the
ENTER key to display the THICK mode settings. (If
short-line options are specified, conditions for short-line options are displayed first; press the
ENTER key again to display THICK mode conditions.)
FORCE
F1
F2
3.
OFFSET
F3
*MODE1 THICK MODE2
STR.=0.0mm END=0.0mm
SPEED
F4
QUALITY
The active mode is indicated by an asterisk. Press the F1 or F3 key to select the desired mode.
Press the
ENTER key upon completing the settings. To specify the overcut value, press the F2
F4
or
key to move the cursor to the setting item to be updated.
CHECKPOINT
Mode 1 is the only option when T1 or T2 is selected as the tool.
Setting Overcut Value
Follow the procedure described below to specify the overcut length for the cutting start and end points.
(Default value: Start: 0 mm; End: 0 mm)
1.
Press a function key from F1 to F4 to select the COND No. for THICK mode. Next, press the
CONDITIONS key to display the conditions.
2.
After entering each condition value, press the
FORCE
F1
F2
3.
OFFSET
*MODE1 THICK MODE2
STR.=0.0mm END=0.0mm
SPEED
ENTER key to display the THICK mode settings.
QUALITY
F3
F4
Use the F2 key to move the cursor to the Start point area and the F4 key to move to the End point
area. Use the
or
POSITION key to raise or lower the value to be entered within the range from
0 to 3.0 mm. Press the
ENTER key upon completing the settings. Press the F1 or F3 key to
select the desired mode and move the cursor to the setting item to be updated.
3 – 15