142 Input/Output Instructions (MSG, GSV, SSV, IOT) Mnemonic Data Type Description .DestinationNode INT To change the Destination Node of a DH+ or CIP with Source ID message, set this member to the required value. .SourceLink INT To change the Source Link of a DH+ or CIP with Source ID message, set this member to the required value. .Class INT To change the Class parameter of a CIP Generic message, set this member to the required value. .Attribute INT To change the Attribute parameter of a CIP Generic message, set this member to the required value. .Instance DINT To change the Instance parameter of a CIP Generic message, set this member to the required value. .LocalIndex DINT If you use an asterisk [*] to designate the element number of the local array, the LocalIndex provides the element number. To change the element number, set this member to the required value. If the message: Then the local array is the: reads data Destination element writes data Source element .Channel SINT To send the message out a different channel of the 1756-DHRIO module, set this member to the required value. Use either the ASCII character A or B. .Rack SINT To change the rack number for a block transfer message, set this member to the required rack number (octal). .Group SINT To change the group number for a block transfer message, set this member to the required group number (octal). .Slot SINT To change the slot number for a block transfer message, set this member to the required slot number. .Path STRING If the message goes over this network: Then specify the slot number in: universal remote I/O octal ControlNet decimal (0-15) To send the message to a different controller, set this member to the new path. • Enter the path as hexadecimal values. • Omit commas [,] For example, for a path of 1, 0, 2, 42, 1, 3, enter $01$00$02$2A$01$03. To browse to a device and automatically create a portion or all of the new string, right-click a string tag and choose Go to Message Path Editor. .RemoteIndex .RemoteElement DINT STRING If you use an asterisk [*] to designate the element number of the remote array, the RemoteIndex provides the element number. To change the element number, set this member to the required value. If the message: Then the remote array is the: reads data Source element writes data Destination element To specify a different tag or address in the controller to which the message is sent, set this member to the required value. Enter the tag or address as ASCII characters. If the message: Then the remote array is the: reads data Source element writes data Destination element Publication 1756-RM003I-EN-P - January 2007
Related documents
Introduction - Artisan Technology Group
Local PDF
Introduction
1756-RM003K-IT-P - Rockwell Automation
1756-RM094 - Literature Library
User`s Manual
Data Mining Configurator
6-in-1 kitchen system sistema de cocina 6 en 1 appareil culinaire 6
syslib-rm011 - Literature Library
Eton SOLARLINK FR500 Specifications
P4-CC-08k050 Manual
Clearance Pricing Manual