Section 4 - User Interface Types and Descriptions
4.2.4
Fluid
“ Input Fluid Data - sets input focus to the first item of the Fluid Data section of the
main screen.
“ Calculate Fluid Properties... - pop-up menu for selecting the fluid correlation used
to estimate the fluid properties.
“ Gases & Vapors - dialog to setup sizing equation for gas and flows.
“ Liquids - dialog to setup sizing equation for liquids.
4.2.5
Sizing
“ Input Sizing Data - sets input focus to first item of the Sizing Data section of the
main screen.
“ Calculation Setup... - dialog to select the sizing parameter and calculation modes.
“ Calculate Sizing Parameter - command to calculate sizing parameter based on user
supplied input data.
4.2.6
Factors
“ M anometer... - dialog for setup of factor for correcting the indicated differential for
the effects of a gas or liquid leg of fluid at static pressure and temperature at the
instrument for mercury U-tube manometers and mercury-manometer-type differential
pressure instruments.
“ Drain/Vent Hole... - dialog for setup of factor adjusting the calculation for the
increased flow through a drain or vent hole.
“ W ater-Vapor Correction... - dialog for setup of factor converting a given volume of
gas flow to a condition of moisture content other than that corresponding to flowing
conditions - enabled only for gases and vapors; grayed or disabled for any other fluid.
“ Saturated Liquid... - dialog for setup of factor correcting calculation for saturated
liquid flows where the vapor quality (percentage of vapor mass to total fluid mass) is
10 percent or less - enabled for all liquids; grayed or disabled for all gases and vapor
fluids.
“ Quality... - dialog for setup of factor correcting calculation for saturated vapor flows
where the vapor quality is 90 percent or more - enabled vapor mass flow fluids;
grayed or disabled for all other fluids.
4.2.7
M eter/Pipe
“ M eter Type - pop-up menu for selecting meter type, e.g., orifice, flow nozzle,
venturi, etc.
“ Pipe Data... - dialog for setup of pipe data, i.e., inner diameter, schedule, etc.
4.2.8
Base...
Activates dialog to set base condition data, i.e., base temperature and pressure,
atmospheric pressure, etc.
4.2.9
Utility
“ Flow Units Setup - dialog for setting and defining various flow units.
“ User - pop-up menu where you can select to enter user, company and customer data.
“ Uncertainty... - dialog for setting and defining the various uncertainty or accuracy
input values.
15