IS300 Series Servo Drive User Manual Function Code Name Appendix Setting Range Min. Unit Default Property 1 2 ★ 0.1 kW Model dependent ★ 1V Model dependent ★ 0.01 A Model dependent ★ 0.01 Hz Model dependent ★ 1 rpm Model dependent ★ - - ☆ F1-00 Motor type selection 0: Common asynchronous motor 1: Variable frequency asynchronous motor 2: PMSM F1-01 Rated power 0.4–1000.0kW F1-02 Rated voltage 0–440 V F1-03 Rated current 0.01–655.35 A F1-04 Rated frequency 0.00–max. frequency F1-05 Rated rotational sped 0–30000 rpm F1-06 to Reserved F1-10 - F1-11 Shaft D inductance 0–65535 1 Model dependent ★ F1-12 Shaft Q inductance 0–65535 1 Model dependent ★ F1-13 Stator resistance 0–65535 1 Model dependent ★ F1-14 Unit 00–12 01 Model dependent ★ F1-15 Counter EMF 0–65535 V 1 Model dependent ★ F1-16 Tuning selection 0: No operation 1: Static tuning (low speed) 2: Dynamic tuning (hispeed) 3: Tuning method 3 1 0 ★ F2-00 Speed loop proportional gain1 0–100 1 60 ☆ F2-01 Speed loop integration time 1 0.01–10.00s 0.01s 0.30s ☆ F2-02 Switchover frequency 1 0.00–F2-05 0.01 Hz 5.00 Hz ☆ F2-03 Speed loop 0–100 proportional gain 2 1 60 ☆ F2-04 Speed loop integration time 2 0.01s 0.30s ☆ Group F2: Vector Control Parameters 0.01–10.00s - 77 -