Download ESA23 Driver Unit System
Transcript
TL : Torque Limit Rate Format : TL data Data : 0 ~ 100 [%] Shipping set : 100 Default :0 ¡ Sets the torque limit. ¡ The Motor torque will be reduced to a percentage (%) of the maximum torque immediately after “TL” is input and the Motor torque is controlled not to exceed the limit. ¡ “TS” or “?TL” reads the current setting. TP : Tell Position Format : TP data/RP Data : 2, 5 Shipping set : None Default : Not omissible ¡ “TP” command reads the current position of the Motor in the position scale set by PS parameter. ¡ If /RP is executed with an /RP option, reading is repeated automatically. ¡ If only “TP data” is executed, the display shows the position at the moment. ¡ To terminate automatic reading, press the BS key. ¡ TP2/RP: in the units of pulse YS, JS1, JS2, RS : 614400 pulses/revolution SS : 491250 pulses/revolution AS, BS, JS0 : 409600 pulses/revolution ¡ TP5/RP : in the units of 0.01° 36000/revolution TR : Tell RDC Position Data Format : TR/RP ¡ TR reads data of RDC position data. ¡ Data is between 0 and 4095. ¡ If TR command is executed with /RP option, reading is repeated automatically. ¡ To terminate automatic reading, press the BS key. ¡ “TR” command reads out the status at the moment. – 11-29 –