Download Accessory Pack User Manual

Transcript
 Accessory Pack User Manual
GETTING STARTED ....................................................................................................... 2 Accessory Pack Overview .................................................................................................... 2 CALIBRATING YOUR DEVICE ......................................................................................... 2 Calibration Overview ........................................................................................................... 2 Setting up Calibration .......................................................................................................... 2 ENVIRONMENT SCAN .................................................................................................. 3 Setting up Sputnik ............................................................................................................... 3 1 GETTING STARTED
Accessory Pack Overview
The Bio-Well Accessory pack contains attachments that will allow you to perform
Environment scans and calibrate your Bio-Well device. In order to conduct these
functions, you must have the Bio-Well device and a Bio-Well Subscription Plus
(or above) subscription. For more information on subscriptions, visit www.BioWell.com.
The Bio-Well Accessory Pack contains
the following items:
-
Grounding Cable
-
Titanium Cylinder
CALIBRATING YOUR DEVICE
Calibration Overview
If you require your scan results to be 100% accurate (scientifically), then you
should calibrate your device once per month. Other times you should calibrate
your device are:
-
The first time the device is used
-
The device is used on a new
computer
-
Large shifts in weather are
experienced
-
Meteorological testing is
conducted
Setting up Calibration
In order to do calibrate your Device, you will need the following items:
-
Bio-Well Device
-
Bio-Well Software
-
Titanium Cylinder
-
Grounding Cable
1. To connect your Bio-Well device to your computer, connect one end
of the USB cable to the back of the Bio-Well device where the USB icon
is indicated. Connect the opposite end of the USB cable to a computer.
2 2. If the Finger Insert is already inserted into the
Bio-Well Lens Window, remove it by gently pressing
down on the bottom, outer edge of the insert and
gently pulling outward, taking care not to scratch
the lens.
3. Place the Titanium Cylinder Insert into the lens
window on the front of the device. Ensure it is
locked in and snug.
4. Connect one end of the Grounding Cable to the
Titanium Cylinder.
5. Connect the opposite of the Grounding Cable to
the back of the Bio-Well device
6. Log in to the Bio-Well software using your username/e-mail and password
associated to your paid subscription.
7. Click on Calibration option in
the main software navigation.
8. Click Start to begin calibration.
Allow the process to run.
9. Once calibration process is
complete, click Apply to apply
adjustments to your device
ENVIRONMENT SCAN
Setting up Sputnik
To set up the Sputnik sensor and conduct an Environment scan, please view the
Sputnik User Guide on the Resources page of www.Bio-Well.com.
3