Download INSTALLATION & PROGRAMMING MANUAL
Transcript
p r o g r a m m in g P90E 4E Program Mode level Installer mode or NessComms. Factory Default OFF: No Remote Disarming. Remote DisArming Allows the control panel to be disarmed remotely by telephone, using a standard DTMF telephone or mobile phone. Programming sequence: P90E 4E toggles the option ON and OFF OFF: No Remote Disarming ON: Remote Disarming enabled P90E 5E Program Mode level Installer mode or NessComms. Factory Default OFF: No Remote AUX control. Notes This option must be on to globally enable remote control of the AUX outputs. See the options for AUX1-4 to individually enable each AUX output for remote control. Remote AUX Control Enables the remote turn ON/OFF of the AUX1, 2, 3 and 4 outputs using a standard DTMF telephone or mobile phone. Programming sequence: P90E 5E toggles the option ON and OFF OFF: No Remote AUX control ON: Remote AUX control enabled RELATED OPTIONS P141E 5E Telephone control AUX1 P142E 5E Telephone control AUX2 P143E 5E Telephone control AUX3 P144E 5E Telephone control AUX4 P90E 6E Remote Status and Arming Available in D8x/D16x V5.6 and later. Enables Remote Status Reporting and Arming using NESSCOMMS™ software. Program Mode level Installer mode or NessComms. This option allows Remote Viewing of the current arming and alarm states and Remote Keypad Operation including arming & disarming. Factory Default Requires NessComms™ V5.2 and later. OFF: No Remote Status Reporting. Programming sequence: P90E 6E toggles the option ON and OFF OFF: No Remote Status Reporting ON: Remote Status Reporting enabled P90E 7E Program Mode level Installer mode or NessComms. Factory Default Remote Event Reporting Enables Remote Event Reporting Programming sequence: OFF: No Remote Event Reporting. P90E 7E toggles the option ON and OFF Notes OFF: No Remote Status Reporting ON: Remote Status Reporting enabled When this option is off, the NessComms Receive Events function will appear to download the event history from the panel, however the NessComms event display will (correctly) be blank. P90E 8E Program Mode level Installer mode or NessComms. Factory Default OFF: No Callback. RELATED OPTIONS P90E 1E Enable Upload/Download. P81E Telephone Number 4, Callback. Callback Mode Enables two methods of connecting by computer for remote upload/download. NO Callback – Allows remote access by computer as long as the panel’s Account Number (P72E) is known. The panel answers on the 2nd incoming call. With Callback – The panel will answer the 2nd call, verify the caller, hang up and then make the Callback using Telephone Number 4. Programming sequence: P90E 8E toggles the option ON and OFF OFF: No Callback ON: Callback Mode enabled Ness D8x / D16x Control Panel – Installation Manual 51