p r o g r a m m in g
P90E 4E
Program Mode level
Installer mode or NessComms.
Factory Default
OFF: No Remote Disarming.
Remote DisArming
Allows the control panel to be disarmed remotely by telephone, using a standard
DTMF telephone or mobile phone.
Programming sequence:
P90E 4E toggles the option ON and OFF
OFF: No Remote Disarming
ON: Remote Disarming enabled
P90E 5E
Program Mode level
Installer mode or NessComms.
Factory Default
OFF: No Remote AUX control.
Notes
This option must be on to globally
enable remote control of the AUX
outputs. See the options for AUX1-4 to
individually enable each AUX output for
remote control.
Remote AUX Control
Enables the remote turn ON/OFF of the AUX1, 2, 3 and 4 outputs using a standard
DTMF telephone or mobile phone.
Programming sequence:
P90E 5E toggles the option ON and OFF
OFF: No Remote AUX control
ON: Remote AUX control enabled
RELATED OPTIONS
P141E 5E Telephone control AUX1
P142E 5E Telephone control AUX2
P143E 5E Telephone control AUX3
P144E 5E Telephone control AUX4
P90E 6E
Remote Status and Arming
Available in D8x/D16x V5.6 and later.
Enables Remote Status Reporting and Arming using NESSCOMMS™ software.
Program Mode level
Installer mode or NessComms.
This option allows Remote Viewing of the current arming and alarm states and Remote
Keypad Operation including arming & disarming.
Factory Default
Requires NessComms™ V5.2 and later.
OFF: No Remote Status Reporting.
Programming sequence:
P90E 6E toggles the option ON and OFF
OFF: No Remote Status Reporting
ON: Remote Status Reporting enabled
P90E 7E
Program Mode level
Installer mode or NessComms.
Factory Default
Remote Event Reporting
Enables Remote Event Reporting
Programming sequence:
OFF: No Remote Event Reporting.
P90E 7E toggles the option ON and OFF
Notes
OFF: No Remote Status Reporting
ON: Remote Status Reporting enabled
When this option is off, the
NessComms Receive Events function
will appear to download the event
history from the panel, however
the NessComms event display will
(correctly) be blank.
P90E 8E
Program Mode level
Installer mode or NessComms.
Factory Default
OFF: No Callback.
RELATED OPTIONS
P90E 1E Enable Upload/Download.
P81E Telephone Number 4, Callback.
Callback Mode
Enables two methods of connecting by computer for remote upload/download.
NO Callback – Allows remote access by computer as long as the panel’s Account
Number (P72E) is known. The panel answers on the 2nd incoming call.
With Callback – The panel will answer the 2nd call, verify the caller, hang up and
then make the Callback using Telephone Number 4.
Programming sequence:
P90E 8E toggles the option ON and OFF
OFF: No Callback
ON: Callback Mode enabled
Ness D8x / D16x Control Panel – Installation Manual