6. Technical Information 6.1 Specification Wind Measurement Parameters Polar Wind Speed & Direction or U and V Vectors Units of Measurement m/s, knots, mph, kph, ft/min Wind Speed Range 0-60m/s (0-134mph) Accuracy 2% @12m/s Resolution 0.01m/s (0.02mph) Threshold 0.01m/s (0.02mph) Wind Direction Range 0-359 Degrees – No dead band Accuracy 3@12m/s Resolution 1 Air Temperature Type Pt100 1/3 Class B Range -35C to + 70C Accuracy 0.1C Resolution 0.1C (0.1F) Units of Measure C or F Relative Humidity Range 0-100% Accuracy 0.8%@23C Resolution 0.1% Units of Measure % RH Dew Point Last Change 08 February, 2013 Resolution 0.1C (0.1F) Accuracy 0.15C (23C ambient temp @20C dew point) Units of Measure C or F MetPak User Manual © Gill Instruments Ltd Page 49