Download SED 64 - Razor Security

Transcript
Installation Overview Diagram
Telecom
Line
4
3
Mode 3
T-Socket
STD DTMF PHONE
FOR PROGRAMMING
( OPTIONAL )
RJ 6p4c
RJ 6p4c
AC
12v
Battery
STATUS
WAKE
SED-64
Line Fail LED
Panel
plug
volts
Earth 16vac +Batt -
240Vac Plug Pac
To zone on Alarm Panel
Alarm Panel
serial
NC C NO
FAULT
C
5
4
3
2
1
SIGNAL
0
9
4
PWR
OH
8 ZONE FAULT
7
LOW BATT
FLT
6
STATUS
2 C 3
1
ZONE INPUTS
10K EOL
sim card holder
prog
PROG
TEST
N.C
NOTE : ALL 24 HR Multi break
Angle on sim
to be as shown
sim card
Expander Board
Port (optional)
FAULT RELAY TRIGGERS ON THE FOLLOWING EVENTS
1/ AC Power fail after 1 hr
2/ Low battery @10.7v
3/ Telecom line no voltage / no current @ 30sec
4/ Gsm signal or registration loss after 8 min
Wire to additional tamper button
installed on Alarm Panel
Volts
MODEL : SED - 64 GSM SYSTEM BY SEC-ENG SYSTEMS AUSTRALIA
AC
12v dc in
OPERATING SED-64 FROM SOURCE 12v DC ONLY
1/ Place 1 amp diode between one side of AC Terminal & + of battery
2/ Run 12v DC now into battery terminal (AC light should be on)
3/ Enable option 48 to a 1 ( disable dynamic battery test )
Earth 16vac +Batt -
PSTN Con 1
1.1
4