Download User Manual
Transcript
KSI User Manual Page 54 Chapter Six—Programming Introduction In addition to the programming information relating to time data given in this manual, there are command codes for triggering the TPRO-VME to add latitude, longitude and elevation data in the FIFO buffer. Register Map Table 6.1—Addressing Base: A6 to A31 Configurable by Wire Wrap Offset 1 D08/D16 MC68153 control register 0 Offset 3 D08/D16 MC68153 control register 1 Offset 5 D08/D16 MC68153 control register 2 Offset 7 D08/D16 MC68153 control register 3 Offset 9 D08/D16 MC68153 vector register 0 Offset B D08/D16 MC68153 vector register 1 Offset D D08/D16 MC68153 vector register 3 Offset F D08/D16 MC68153 vector register 4 Offset 11 D08/D16 MC68153 Command register 0 Offset 13 D08/D16 MC68153 Internal event register 1 Offset 14 D08/D16 MC68153 D32 longword high order time read and freeze release Offset 15 D08/D16 FIFO Data read Offset 17 Not used 1 Offset 18 D32 longword time freeze ad low order data Offset 19 D08/D16 Status Register Status Bit 0 “0” FIFO not empty, “1” FIFO empty Status Bit 1 “0” input code amplitude <500mV pk/pk, “1” Input code amplitude> 500mV pk/pk Status Bit 2 “0” Synchronization error, “1” Good synchronization Models TPRO-VME and TSAT-VME Q Synchronizable Timecode Generators Edition 1.4