Download Data sheet Shirla All in one - fully automatic cable
Transcript
Technical data Mains supply Max. power consumption Display Testing Output voltage Output current Resolution Resistance measurement Voltage and current limitation 110 VAC … 240 VAC, 50 Hz / 60 Hz Max. 200 VA Illuminated digital LCD display, automatic adjustment of brightness, 320 x 240 dots 0 – 10 kV 10 mA @ 5 kV, 5 mA @ 10 kV 1 μA Yes Yes Cable sheath fault prelocation Definable cable sections Voltage and current limitation 4 wire bridge according to Murray and Glaser Up to 10 kV Max. 50 mA ± 0,1% Fully automatic balancing and measuring procedure 50 sections Yes Cable sheath fault pin pointing Pulse voltage Output current Pulse code 100V – 10kV Max. 700 mA Three selectable pulse patterns Measuring technique Measuring voltage Measuring current Accuracy Measuring sequence General Battery operation Reporting function Working temperature Storage temperature Max. relative humidity Dimension (in mm) Weight including accessories BAUR Pruef- und Messtechnik GmbH Raiffeisenstrasse 8, 6832-Sulz/Austria [email protected] www.baur.at Integrated rechargeable battery Battery operation for all applications For testing and prelocation via USB 2.0 port -20°C....+50°C -40°C....+60°C not condensing Approx. 440 x 490 x 220mm (L x H x W) < 20 kg T +435522/4941-0 F +435522/4941-3 Id No. 826-085 07/2007 Subject to alteration