Download HeartWare Ventricular Assist System Instructions for Use
Transcript
HeartWare® Ventricular Assist System Instructions for Use *Infection Control Guidelines and Driveline Care based on recommendations from “Multicenter Experience: Prevention and Management of Left Ventricular Assist Device Infections”. Chinn et al. ASAIO Journal 2005; 51:461–470 CAUTION: ALWAYS examine the driveline for evidence of tears, punctures or breakdown of any of the material during exit site dressing changes. Driveline damage may affect HeartWare® System performance. 5. Perform exit site care every 24-48 hours using an antiseptic cleansing agent, such as a diluted chlorhexidine scrub solution. Following aseptic cleansing, rinse and dry the site to avoid tissue injury. Aseptic technique should be followed anytime the dressing is removed and the exit site is exposed, inspected, dressed or handled. When performing exit site care, be sure to wear a cap, mask and sterile gloves. CAUTION: AVOID the use of prophylactic topical antibiotic ointments such as silver sulfadiazine, betadine or polymyxin-neomycin-bacitracin on the tissue around the driveline exit site as these ointments can injure the tissue. 6. Immobilize the percutaneous lead with occlusive dressing and if necessary, a Hollister clip, Montgomery strap, or a custom-made percutaneous lead immobilization binder or belt. Keep the extra external length of the driveline under a binder or clothing. 7. Complicated, non-routine driveline dressing changes that involve exit site infections may require assistance/supervision from a health care professional. 8. For wounds/incisions other than the driveline exit site that require dressing changes and/or other care, the ability of the patient and caregiver to provide that care will be evaluated by the implanting center. Treatment plans will be dependent upon this evaluation. 18.6 Arrhythmias The HVAD® Pump functions most effectively when adequate and stable amounts of preload are available. A stable supraventricular rhythm helps to optimize right heart performance and provide the HVAD® Pump with preload. Many heart failure patients will have permanent pacemakers and internal defibrillators in place by the time an LVAD is implanted. These devices are often needed in the early postoperative period. 18.7 Right Heart Failure Right heart failure is common in patients receiving LVADs. Right heart failure usually develops within the first 24 hours after LVAD implant. Warning signs include increasing right atrial pressure (RAP) with concurrent decreases in the pulmonary capillary wedge pressure (PCWP) and LVAD flow. Systemic hypotension, tachycardia and a decrease in urine output soon follow. Volume should be given to increase the RAP to 15-18mmHg. This can be accomplished quickly and easily in the operating room while the patient is on cardiopulmonary bypass. Increasing the RAP to >20mmHg is usually ineffective. After optimizing intravascular volume, increasing inotropic drug support in conjunction with pulmonary vasodilators such as nitric oxide is usually effective. If volume and pharmacological therapy fail, a right ventricular assist device (RVAD) should be considered. Late right heart failure (weeks to months) post LVAD implant is unusual but would manifest itself with similar but less acute symptoms. The etiology of late right heart failure may be a progression of chronic heart disease such as coronary artery disease and/or right ventricular infarction. The cause of the right heart dysfunction should be identified and treated appropriately. 79