D. Un-tighten a clamp screw② of the wiper base plate. When the wiper and the needle center are parallel, move the wiper base plate③ up and down to give a clearance of 14.5~15.5mm between the needle plate① and the wiper. Fasten back the clamp screw② afterwards. ② ① ③ [Figure 28] E. Unfasten the wiper crank screw④. Move the wiper crank⑤ left and right to set a clearance of 25mm between the needle center and the wiper. Tighten back the clamp screw④ after adjustments. ④ ⑤ [Figure 29] F. After arranging the connectors as shown in the Figure, use the wiper cover clamp screw⑦ to place the wiper cover⑥. ⑥ ⑦ [Figure 30] [Caution] To use the wiper solenoid, set function code A-18 related to general sewing at “100”. 21